Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Añadir filtros








Intervalo de año
1.
Arq. bras. oftalmol ; 76(3): 147-151, maio-jun. 2013. ilus, tab
Artículo en Portugués | LILACS | ID: lil-681845

RESUMEN

OBJETIVOS: Avaliar a posição das alças das lentes intraoculares implantadas intencionalmente no sulco ciliar, em olhos submetidos à cirurgia de catarata com complicação de ruptura de cápsula posterior, e correlacionar os achados com alterações clínicas observadas no exame oftalmológico, utilizando a biomicroscopia ultrassônica. MÉTODOS: Onze olhos (11 pacientes) que apresentaram ruptura de cápsula posterior durante a cirurgia de catarata com implantação intencional das alças no sulco ciliar foram submetidos ao exame oftalmológico e biomicroscopia ultrassônica. Biomicroscopia ultrassônica avaliou os seguintes parâmetros: posicionamento da porção distal das alças, inclinação e descentração da lente intraocular. O exame oftalmológico foi focalizado para avaliar a presença de "flare" e células na câmara anterior, depósitos na lente e defeitos de transiluminação de íris. A pressão intraocular foi medida, a pigmentação do trabeculado foi determinada, e a avaliação fundoscópica foi necessária para afastar a presença de ruptura retiniana periférica e edema de mácula. RESULTADOS: Tempo pós-operatório médio para os exames: 103,09 ± 32,93 dias. Assimetria da posição foi observada em 3 olhos (27,2%), que tinham alça no sulco ciliar e a segunda alça localizada na pars plana em 2 olhos, associada à inclinação e descentração da lente intraocular; ou no corpo ciliar (1 olho). O exame oftalmológico observou: 5 (45,5%) olhos com defeitos de transiluminação de íris, 2 (18,1%) olhos com descentração da lente intraocular; 1 olho (9%) apresentou hipertensão intraocular. Em todos os casos observou-se hiperpigmentação do trabeculado à gonioscopia. Nenhum caso de rotura periférica de retina e/ou edema de mácula foi relatado. CONCLUSÕES: A biomicroscopia ultrassônica foi capaz de localizar as alças das lentes intraoculares implantadas intencionalmente no sulco ciliar durante cirurgia complicada de catarata, e pôde demonstrar a relação da descentração da lente intraocular com a implantação assimétrica das alças.


PURPOSE: To evaluate the position of haptics of intraocular lens intentionally implanted in the ciliary sulcus in eyes undergoing cataract surgery complication associated with intraoperative posterior capsule rupture, as well as to correlate the findings with clinical changes observed in ophthalmic examination, utilizing ultrasound biomicroscopy. METHODS: Eleven eyes (11 patients) who had posterior capsule rupture during cataract surgery with intentional implantation of the haptics in the ciliary sulcus, underwent complete ophthalmic examination and ultrasound biomicroscopy. Ultrasound biomicroscopy evaluated the parameters: positioning of the distal portion of the haptics, tilt and decentration of the intraocular lens. Ophthalmic examination was aimed to evaluate the presence of flare and cells in the anterior chamber, deposits on the lens and iris transillumination defects. Intraocular pressure was measured, pigmentation of the trabecular meshwork was determined, and a fundoscopic evaluation was needed to rule out peripheral retinal rupture and macular edema. RESULTS: Mean postoperative time for the examinations: 103.09 ± 32.93 days. Asymmetry of the haptics positioning was observed in 3 eyes (27.2%) that had one haptic in the ciliary sulcus, the second haptic was placed in the pars plana in 2 eyes, associated to intraocular lens tilt and decentration; or in the ciliary body (1 eye). Ophthalmic examination observed: 5 (45.5%) eyes with iris transillumination defects, 2 (18.1%) with intraocular lens decentration; 1 eye (9%) presented ocular hypertension. In all cases trabecular hyperpigmentation was observed at gonioscopy. No cases of peripheral retinal rupture and/or macular edema were reported. CONCLUSIONS: Ultrasound biomicroscopy was able to locate the intraocular lens haptics intentionally implanted in the ciliary sulcus during complicated cataract surgery, and could demonstrate the relation of intraocular lens decentration to assymetric haptic implantation.


Asunto(s)
Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Cuerpo Ciliar/cirugía , Lentes Intraoculares , Implantación de Lentes Intraoculares/métodos , Microscopía Acústica/métodos , Facoemulsificación/métodos , Gonioscopía , Facoemulsificación/efectos adversos , Ruptura de la Cápsula Posterior del Ojo/etiología , Valores de Referencia , Tonometría Ocular , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA