RESUMEN
Ten consecutive cases of perforating ocular injuries with retained intraocular foreign bodies over a period of 2 years were reviewed retrospectively in this study. All cases were operated upon by a 3 port pars plana vitrectomy and if necessary endolaser done. All ten cases (100%) were successful in terms of intraocular foreign body removal through the pars plana sclerotomy but ultimately we lost three [3] [30%] cases of which two had retinal detachments with P.V.R. D-3 preoperatively and the other had endophthalmitis. Of the seven (70%) successful cases four eyes (40%) had a post-operative vision of 6/12 or better while 2 [20%] had 6/24 and the last had 6/60 [10%]. Nine cases [90%] had a magnetic Intraocular foreign body. Various complications of Intraocular foreign bodies like vitreous haemorrhage, retinal incarceration, cataract and retinal detachment were noted preoperatively. Silicone oil was used in three (30%) cases. Sulfur Hexafluoride was used in 5 cases (50%). Endolaser photocoagulation was done in 7 cases (70%).