Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Añadir filtros








Intervalo de año
1.
J. appl. oral sci ; 15(6): 506-511, Nov.-Dec. 2007. tab
Artículo en Inglés | LILACS | ID: lil-471108

RESUMEN

This study evaluated the effect of water-bath and microwave post-polymerization treatments on the flexural strength and Vickers hardness of four autopolymerizing reline resins (Duraliner II-D, Kooliner-K, Tokuso Rebase Fast-TR and Ufi Gel Hard C-UGH) and one heat-polymerized acrylic resin (Lucitone 550-L), processed using two polymerization cycles (short cycle - 90 minutes at 73ºC and 100ºC for 30 minutes; and long cycle - 9 hours at 71ºC). For each material, thirty specimens (64 x 10 x 3.3 mm) were made and divided into 3 groups (n=10). Specimens were tested after: processing (control group); water-bath at 55ºC for 10 minutes (reline materials) or 60 minutes (L); and microwave irradiation. Flexural strength tests were performed at a crosshead speed of 5 mm/min using a three-point bending device with a span of 50 mm. The flexural strengths values were calculated in MPa. One fragment of each specimen was submitted to Vickers hardness test. Data were analyzed by 2-way ANOVA followed by Tukey's HSD test (alpha=0.05). L microwaved specimens (short cycle) exhibited significantly higher flexural strength means than its respective control group (p<0.05). Water-bath promoted a significant increase (p<0.05) in flexural strength of K and L (long cycle). The hardness of the tested materials was not influenced by the post-polymerization treatments. Post-polymerization treatments could be used to improve the flexural strength of some materials tested.

2.
Araraquara; s.n; 2006. 187 p. ilus, tab.
Tesis en Portugués | LILACS, BBO | ID: lil-466857

RESUMEN

O estudo avaliou o efeito do reembasamento, da ciclagem mecânica, da ciclagem térmica e da desinfecção por microondas sobre a força máxima de fratura, a deformação, a energia de ruptura e a estabilidade dimensional de bases de prótese. O efeito das ciclagens mecânica e térmica foi avaliado utilizando 28 bases de prótese intactas com 3 mm de espessura e 56 bases de prótese com 2 mm de espessura. Estas bases foram obtidas a partir de um modelo padrão metálico do arco superior confeccionadas com a resina acrílica para microondas Acron MC (AC-MC), de acordo com as instruções do fabricante (500W por 3 minutos). Para verificar o efeito do reembasamento, as bases de prótese com 2 mm de espessura foram reembasadas com 1 mm de material reembasador (New Truliner - NTL ou Tokuyama Rebase Fast II - TRFII). Em seguida, as bases de prótese intactas ou reembasadas foram divididas aleatoriamente em 4 grupos (n=7) e o ensaio mecânico de resistência à compressão foi realizado após seguintes condições experimentais: sem tratamento (controle); 5.000 ciclos térmicos entre 5º e 55ºC; 10.000 ciclos mecânicos a um frequência de 0,8 Hz e uma força de 150N e; ciclagem térmica e posterior ciclagem mecânica. Todas as bases de prótese foram submetidas ao ensaio mecânico em uma máquina universal Instron 5565, utilizando-se uma velocidade de 5mm/min e uma célula de carga de 10 kN...


Asunto(s)
Resinas Acrílicas , Rebasado de Dentaduras , Desinfección , Microondas
3.
Araraquara; s.n; 2006. 187 p. tab, ilus.
Tesis en Portugués | LILACS, BBO | ID: biblio-863676

RESUMEN

Este estudo avaliou o efeito da desinfecção por irradiação de energia de microondas na porosidade superficial de quatro reembasadores rígidos (Kooliner - K, New Truliner - NT, Tokuso Rebase - TR, Ufi Gel Hard ­ UGH) e uma resina termopolimerizável para base de prótese (Lucitone 550 - L). Vinte amostras de cada material (20 x 10 x 3mm) foram divididas em 4 grupos (n=5): G1 ­ sem tratamento ­ controle; G2 ­ amostras imersas em 200 mL de água destilada e submetidas a 2 ciclos de irradiação (650W/6min) no mesmo dia; G3 ­ 1 ciclo diário de irradiação, por 7 dias, com as amostras imersas em água destilada entre os ciclos; e G4 ­ amostras imersas em água destilada a 370 C, por 7 dias. As amostras foram fotografadas em microscópio eletrônico de varredura e as microfotografias analisadas em analisador de imagem Leica Qwin, para determinar o número e a área total de poros. Para avaliar a porosidade entre a região central e a periferia, foi utilizado o teste não-paramétrico de Wilcoxon ao nível de 5% de significância. Para avaliar a porosidade entre os grupos experimentais foi utilizado o teste de Kruskal Wallis, seguido por comparações múltiplas não-paramétricas, também ao nível de 5% de significância. Os resultados demonstraram que não houve diferença significativa (P>0,05) entre a região central e a periferia. A avaliação entre os grupos experimentais demonstrou que a porosidade do material K foi significantemente aumentada (P<0,05), após 7 ciclos de irradiação. Nenhuma diferença significante (P>0,05) foi encontrada para os materiais NT e L, em todas as condições avaliadas. Quando comparada ao grupo G1 (sem tratamento), a porosidade da TR e UGH foi significantemente diminuída (P<0,05), após 7 ciclos de irradiação. Concluiu-se que: 1) As irradiações por energia de microondas aumentaram o número de poros para o material K (P<0,05), quando este foi submetido a 7 ciclos, em relação ao G1. Entretanto, a área total de poros não exibiu essa influência (P>0,05) em todos os grupos avaliados. 2) O material NT não sofreu efeito das irradiações para o número de poros em todos os grupos. Entretanto, a área de poros foi reduzida (P<0,05), quando foram utilizados 7 ciclos (G3), em comparação a 2 ciclos (G2). 3) As microondas reduziram o número de poros para o material TR (P<0,05), quando este foi submetido a 7 ciclos, em comparação ao G1 e G2. Sua área total de poros, no G3, exibiu redução significativa, em relação aos demais grupos avaliados. 4) A resina UGH, quando submetida a 7 ciclos de irradiação (G3), teve o número de poros reduzido (P<0,05), em relação ao G1 e G4. Entretanto, a área total de poros foi estatisticamente igual para todos os grupos. 5) O número e a área de poros do material L não foram influenciados (P>0,05) pelas irradiações


This study evaluated the effect of microwave irradiation on the surface porosity of four hard chairside reline materials (Kooliner-K, New TrulinerNT, Tokuso Rebase-TR, Ufi Gel Hard­UGH) and one heat-polymerizing denture base acrylic resin (Lucitone 550-L) Twenty specimens (20X10X3mm) were made for each material and divided into four groups (n=5): G1-no treatment (control), G2­specimens immersed in distilled water and submitted to 2 cycles of microwave irradiation (650W/6 min) consecutively on the same day; G3­daily microwave irradiation for 7 days, with specimens immersed in distilled water at 370 C between exposures; G4­specimens immersed in distilled water at 370 C for 7 days. Scanning electron microphotographs of the specimens (SEM) were analyzed using Leica Qwin image analyser software to determine the number and total area of porosities. Data were statistically analyzed with Wilcoxon test for paired analysis (P=0.05) to determine differences between the center and the periphery. Differences between the experimental groups were tested using the Kruskal-Wallis test. The results demonstrated that the number and the total area of pores did not differ significantly between the central and peripheral zones. The number and the total area of pores of K was significantly increased after 7 cycles (P<.05). Materials NT and L specimens showed no significant differences in the number of pores among all groups evaluated. However, for material NT, significant difference (P<.05) was observed between G2 and G3 in the total area of pores. The number of pores of TR and UGH was significantly decreased (P<.05) after 7 cycles when compared to G1. The area total of pores of the TR was significantly affected after 7 cycles. It was concluded that 1) Microwave irradiation promoted a significant increased (P<.05) in the number of pores for material K after 7 cycles; however, the total area of pores was not affect by irradiation in all groups evaluated. 2) Material NT was not affected by irradiation for the number of pores; however, the total area of pores was decrease after 7 cycles, when compared to G2. 3) For material TR, microwave irradiation decreased (P<.05) the number of pores after 7 cycles, compared to G1 and G2. The total area of pores of G3 was significantly decreased after 7 cycles. 4) Material UGH showed a significant decrease (P<.05) for number of pores when submitted to 7 cycles, compared to G1 and G4; however, the total area of pores was statically equal in all groups evaluated 5) For material L, the number and total area of pores were not affected by irradiations


Asunto(s)
Resinas Acrílicas , Desinfección , Microondas , Rebasado de Dentaduras
4.
Rev. odontol. UNESP ; 34(3): 119-128, jul.-set. 2005. ilus, tab
Artículo en Portugués | LILACS, BBO | ID: lil-519056

RESUMEN

As próteses adesivas surgiram como uma alternativa protética, tendo em vista o seubaixo custo, ser uma técnica mais conservadora e facilidade laboratorial. Mais recentemente, emrazão da necessidade de soluções clínicas estéticas, novos materiais foram introduzidos no mercadoe utilizados na confecção de próteses adesivas sem metal. Os materiais utilizados são: resinascompostas reforçadas por fibras e sistemas cerâmicos de alta resistência. O objetivo deste trabalhofoi discutir, por meio de uma revisão de literatura, as formas de preparo, os tipos de materiais, asvantagens e desvantagens da utilização de próteses adesivas sem metal. Com base nas informaçõesda literatura, pôde-se concluir que as próteses adesivas sem metal são uma alternativa promissorana substituição de um elemento dental devido a sua superioridade estética, biocompatibilidade efacilidade de confecção, principalmente para compósitos reforçados por fibras. Além disso, suaresistência apresenta resultados satisfatórios in vitro. Entretanto, há poucas evidências científicascom relação a formas de preparo ideais para os retentores de ambos os materiais a serem utilizadosrotineiramente na clínica. Assim, acompanhamentos longitudinais deveriam ser realizados paraverificar o comportamento dessas próteses na cavidade bucal antes que possam ser indicadas comotratamento de rotina na prática clínica diária.


The resin bonded bridge sets up as prosthodontic alternative based on its costeffective,conservative techniques and easiness of laboratory manufacturing. Nowadays, theclinical practice has been requiring esthetic solutions and, consequently, new materials have beenintroduced and used in the metal free resin bonded bridge manufacture. The materials used arefibre-reinforced composite and high-strenght ceramic systems. The purpose of this study was todiscuss through a literature review the cavity design, types of materials used and the advantagesand disadvantages of the metal free resin bonded bridges. Based on the reviewed literature it couldbe concluded that the metal free resin bonded bridges are a promising solution for the replacementof a tooth because of their improved esthetics, biocompatibility and simple technique, specialyfor the fiber reinforced composite. Moreover, this kind of prosthesis presents satisfactory in vitrostrenght results. However, there is little scientific evidence about the adequated cavity and connectordesigns that offer support to use this prosthesis in clinical routine. Therefore, longitundinal studiesshould be performed in order to investigate the clinical behaviour of these prosthesis in the oralenvironment before their indication as a routine modality of treatment.


Asunto(s)
Estética Dental , Preparación de la Cavidad Dental , Dentadura Parcial Fija con Resina Consolidada
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA