Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Healthcare Informatics Research ; : 95-101, 2022.
Artículo en Inglés | WPRIM | ID: wpr-914488

RESUMEN

Objectives@#Aquatic therapy is a significant intervention method for both patients and healthy individuals. However, in clinical practice, quantitative measurements are rarely applied in aquatic therapy due to the disadvantages of submerging expensive instruments in water. In this study, we used readily available smartphones and armbands to measure leg segments and joint angles during aquatic gait and evaluated the reliability of these measurements. @*Methods@#Waterproof smartphones were strapped to the trunk, thighs, and shanks of 19 healthy young adults using armbands. The angles of the trunk, thigh, and shank segments were measured during aquatic gait. The measurements were repeated 1 day later. The data were analyzed to obtain the angles of the hip and knee joints. @*Results@#Measurement repeatability, calculated using the intraclass correlation coefficient (ICC), was the highest for the shank segment range of motion (ROM) (first 46.79° ± 5.50°, second 50.12° ± 9.98°, ICC = 0.78). There was high agreement in trunk segment ROM (first 6.36° ± 1.42°, second 4.29° ± 1.83°, ICC = 0.73), thigh segment ROM (first 33.49° ± 5.18°, second 37.31° ± 8.70°, ICC = 0.62), and knee joint ROM (first 52.43° ± 11.26°, second 62.19° ± 16.65°, ICC = 0.68) and fair agreement in hip joint ROM (first 34.60°±4.71°, second 37.80° ± 7.84°, ICC = 0.59). @*Conclusions@#Smartphones can be used to reliably measure leg segments and joint angles during aquatic gait, providing a simpler method for obtaining these measurements and enabling the wider use of aquatic motion analysis in clinical practice and research.

2.
Healthcare Informatics Research ; : 183-188, 2017.
Artículo en Inglés | WPRIM | ID: wpr-41210

RESUMEN

OBJECTIVES: This study evaluated and validated the reliability of smartphones as measuring equipment for the dorsi-plantar flexion of ankle joint position sense (JPS) ability. METHODS: The subjects were 20 healthy young students in their 20s. We confirmed the concurrent validity by comparison with existing electrogoniometer data. The reliability of the smartphone was confirmed using the test-retest method. RESULTS: In the case of dorsiflexion, there was no significant difference between the smartphone and electrogoniometer groups (p > 0.05). Regarding the correlation, it was significantly high (r = 0.65, p 0.05), the correlation was significantly high (r = 0.69, p 0.05), the correlation was intermediate (r = 0.59, p 0.05), the correlation was significantly high (r = 0.63, p < 0.05), and the ICC(3,1) was good (ICC(3,1) = 0.76). CONCLUSIONS: The results showed that smartphones provide high validity and reliability as measurement equipment for JPS of dorsi-plantar flexion of the ankle. Finally, the study also considers that smartphone-based JPS measuring methods may replace the traditional and expensive methods that are currently being used for the same purpose.


Asunto(s)
Humanos , Articulación del Tobillo , Tobillo , Articulaciones , Métodos , Propiocepción , Reproducibilidad de los Resultados , Teléfono Inteligente
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA