Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Añadir filtros








Intervalo de año
1.
Artículo en Inglés | WPRIM | ID: wpr-762472

RESUMEN

BACKGROUND@#Hereditary breast and ovarian cancer syndrome (HBOC) is caused by pathogenic variants in BRCA and other cancer-related genes. We analyzed variants in BRCA gene and other cancer-related genes in HBOC patients to evaluate the clinical validity of next-generation sequencing (NGS) multi-gene panel testing.@*METHODS@#The BRCA1/2 NGS testing was conducted for 262 HBOC patients. Multiplex ligation-dependent probe amplification and direct Sanger sequencing were performed for confirmation. Multi-gene panel testing was conducted for 120 patients who did not possess BRCA1/2 pathogenic variants but met the National Comprehensive Cancer Network criteria.@*RESULTS@#Pathogenic variants in BRCA1/2 were detected in 30 HBOC patients (11.5%). Additionally, four out of the 120 patients possessed pathogenic variants by multi-gene panel testing (3.3%): MSH2 (c.256G>T, p.Glu86*), PMS2 (c.1687C>T, p.Arg563*), CHEK2 (c.546C>A, p.Tyr182*), and PALB2 (c.3351-1G>C). All the four patients had a family history of cancer.@*CONCLUSIONS@#Multi-gene panel testing could be a significant screening tool for HBOC patients, especially for those with a family history of cancer.

2.
Artículo en Coreano | WPRIM | ID: wpr-107154

RESUMEN

BACKGROUND: Studies using a transcranial Doppler (TCD) to establish cerebral vasoreactivity (CVR) have mostly focused on the anterior circulation. The purpose of this study is not only to evaluate the feasibility of the power motion mode Doppler (PMD) with a probes fixating device, but also to simultaneously measure the CVR between the middle cerebral artery (MCA) and the basilar artery (BA) during hypercapnea simulated by the rebreathing technique. METHODS: Twenty eight healthy volunteers were enrolled. Baseline hemodynamic values (heart rate, blood pressure) were measured while volunteers sat in a comfortable position for 5 minutes. The TCD was performed in two steps. First, velocities and spectra of the MCAs were simultaneously monitored. Then, the velocities and spectra of the MCA and BA were simultaneously monitored by a headset that included an anterior-posterior probes fixating device. The equation for CVR was ([maximum mean velocity baseline mean velocity] x 100/baseline mean velocity). RESULTS: Baseline mean velocities were revealed as follows: (64.0+/-13.7, 65.0+/-11.9 cm/s in right and left MCA; p>0.05; 67.3+/-12.2, -45.3+/-7.6 cm/s in dominant MCA and BA). CVR did not differ between the dominant MCA and the BA (46.1+/-12.1, 46.0+/-15.1%; p>0.05), nor between the right and left MCAs (46.9+/-15.2, 46.4+/-14.8%; p>0.05). There was a positive linear correlation between the CVR of the dominant MCA and that of the BA (r=0.856; p<0.001). CONCLUSIONS: PMD with a probes fixating device for accurate insonation is a useful tool for evaluating the relative CVR between the MCA and BA. Our study suggests that CVR values of the BA are similar to those of the MCA.


Asunto(s)
Arteria Basilar , Voluntarios Sanos , Hemodinámica , Arteria Cerebral Media , Voluntarios
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA