International Eye Science ; (12): 205-209, 2011.
Artículo en Chino | WPRIM | ID: wpr-641814

RESUMEN

AIM: To compare the efficiency and safety of fibrin glue to suture technique in pterygium surgery performed with limbal autograft.METHODS: A prospective randomised clinical trial was carried out in 58 eyes of 58 patients operated for primary nasal pterygium. Autologous conjunctival graft taken from the superotemporal limbus was used to cover the sclera after pterygium excision. In 29 eyes, the transplant was attached to the sclera with a fibrin tissue adhesive (Beriplast P) and in 29 eyes with 8- 0 Virgin silk sutures. The Mann-Whitney U test was used for statistical analysis. Postoperative patient discomfort (pain, stinging, watering) and biomicroscopic findings (hyperemia, edema) were graded. Patients were followed up at least for six months.RESULTS: Subconjunctival hemorrhage occured under the graft in one patient in group 1. In seven cases of group 2, sutures were removed at the 15th day because of granulomatous tissue reaction. Patient symptoms were significantly less and biomicroscopic findings were better in group 1. Pterygium recurrence was seen in one case of group 1, and 2 cases of group 2. Average surgery cost was higher (P<0.05) and surgery time was shorter (P<0.05) in fibrin group. CONCLUSION: Using fibrin glue for graft fixation in pterygium surgery causes significantly less postoperative pain and shortens surgery time significantly.