Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Chinese Journal of Thoracic and Cardiovascular Surgery ; (12): 26-30, 2020.
Artículo en Chino | WPRIM | ID: wpr-871579

RESUMEN

Objective:To detect the hemodynamic mechanism of the novel endovascular stent on complicated abdominal aortic aneurysms by Computational Fluid Dynamics(CFD) firstly, and then compare the effect of the novel endovascular stent and the streamliner multilayer flow modulator(SMFM) stent.Methods:All medical images were obtained by computed tomography. A semiautomatic segmentation protocol within Mimics(v17.0; Materialise, Leuven, Belgium) was used to extract the threedimensional aortic aneurysms. The stents was generated numerically and fitted along the aortic aneurysms. The lumen volume represented the fluid domain that was discretised in smaller volumes, which defined a mesh within the ICEM software(Ansys ICEM CFD v15.0). Hemodynamic analysis was performed with software Fluent 16.0.Results:Both kinds of stents can change the pattern of flow distribution. Compared with SMFM, the novel endovascular stent can significantly reduce the flow velocity in aneurysms, the shear force and the pressure on the aneurysms wall.What’s more, the flow velocity of the branch artery was accelerated by the novel endovascular stent.Conclusion:The novel endovascular stent can significantly reduce the flow velocity in aneurysms, the shear force and the pressure on the aneurysms wall, and acceleratethe the flow velocity of the branch artery.

2.
Chinese Journal of Thoracic and Cardiovascular Surgery ; (12): 26-30, 2020.
Artículo en Chino | WPRIM | ID: wpr-799067

RESUMEN

Objective@#To detect the hemodynamic mechanism of the novel endovascular stent on complicated abdominal aortic aneurysms by Computational Fluid Dynamics(CFD) firstly, and then compare the effect of the novel endovascular stent and the streamliner multilayer flow modulator(SMFM) stent.@*Methods@#All medical images were obtained by computed tomography. A semiautomatic segmentation protocol within Mimics(v17.0; Materialise, Leuven, Belgium) was used to extract the threedimensional aortic aneurysms. The stents was generated numerically and fitted along the aortic aneurysms. The lumen volume represented the fluid domain that was discretised in smaller volumes, which defined a mesh within the ICEM software(Ansys ICEM CFD v15.0). Hemodynamic analysis was performed with software Fluent 16.0.@*Results@#Both kinds of stents can change the pattern of flow distribution. Compared with SMFM, the novel endovascular stent can significantly reduce the flow velocity in aneurysms, the shear force and the pressure on the aneurysms wall.What’s more, the flow velocity of the branch artery was accelerated by the novel endovascular stent.@*Conclusion@#The novel endovascular stent can significantly reduce the flow velocity in aneurysms, the shear force and the pressure on the aneurysms wall, and acceleratethe the flow velocity of the branch artery.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA