Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
China Journal of Orthopaedics and Traumatology ; (12): 1142-1146, 2023.
Artículo en Chino | WPRIM | ID: wpr-1009201

RESUMEN

OBJECTIVE@#To investigate CT values of cancellous bone in femoral neck in adults over 60 years with proximal femoral fractures.@*METHODS@#From January 2020 to December 2020, a retrospective analysis was performed on 280 subjects aged 60 years or older who underwent bilateral hip CT examination, including 85 males and 195 females, 120 on the left side and 160 on the right side, aged 75 (66, 82) years old. One hundred thirty-six patients with proximal femoral fractures were included in study group and 144 patients without fractures were included in control group. GEOptima CT was used to scan and reconstruct horizontal, coronal and sagittal layers of proximal femur. CT values of cancellous bone in femoral neck were measured and compared between two groups. The relationship between CT values of cancellous bone of femoral neck and proximal femoral fracture was analyzed statistically.@*RESULTS@#In terms of age, fracture group aged 79(73.3, 85.0) years old, non-fracture group aged 69.5 (64.0, 78.8) years old, and had significant difference in age between two groups (P<0.05). In terms of CT value, regional CT value in fracture group was 8.62(-3.62, 27.15) HU, which was lower than that in non-fracture group 34.31(-5.93, 71.74) HU(P<0.05). CT value on coronal view in fracture group was -8.48(-30.96, 17.46) HU, which was lower than that in non-fracture group 40.49(5.55, 80.71) HU (P<0.05). CT value on sagittal view in fracture group was -31.28(-54.91, -5.11) HU, which was lower than that in non-fracture group 7.74(-20.12, 44.54) HU (P<0.05). CT values on horizontal view in fracture group was 0.17(-23.13, 24.60) HU, which was lower than that in non-fracture group 46.40(10.42, 85.18) HU(P<0.05). The mean regional CT values among three planes in the fracture group were lower than those in the non-fracture group. Logistic regression analysis showed coronal CT value was influencing factors of proximal femoral fracture, and it could be written into regression equations that predict probability of fracture.@*CONCLUSION@#In adults aged over 60 years old, CT values of cancellous bone of femoral neck decreased with increasing age. The smaller CT value of cancellous bone of femoral neck, the greater risk of proximal femoral fracture.


Asunto(s)
Masculino , Adulto , Femenino , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Fracturas Femorales Proximales , Estudios Retrospectivos , Cuello Femoral , Fracturas de Cadera/cirugía , Tomografía Computarizada por Rayos X , Densidad Ósea
2.
China Journal of Orthopaedics and Traumatology ; (12): 20-25, 2022.
Artículo en Chino | WPRIM | ID: wpr-928260

RESUMEN

OBJECTIVE@#To investigate the clinical effect of porous tantalum Jumbo cup on acetabular reconstruction in revision of total hip arthroplasty.@*METHODS@#From September 2014 to December 2017, 18 patients(18 hips) with acetabular defect were reconstructed by porous tantalum Jumbo cup technology, including 6 males and 12 females;the age ranged from 54 to 76 years old with an average of(63.8±15.3) years. There were 6 cases of paprosky typeⅡA, 8 cases of typeⅡB, 2 cases of typeⅡC and 2 cases of type Ⅲ a. Harris score and visual analogue scale (VAS) were performed before and after operation. Imaging examination was performed to evaluate the position of hip rotation center and prosthesis, and to judge whether acetabular loosening, displacement and complications existed.@*RESULTS@#All cases were followed up for 13 to 49 months, with an average of 20.6 months. Harris score increased from 54.6±4.7 to 86.5±3.2 one year after operation(P<0.01), and VAS score decreased from 6.8±0.7 to 0.8±0.6 one year after operation (P<0.01). The transverse coordinate of hip rotation center was (3.52±0.72) cm before operation and (3.47±0.54) cm after operation (P>0.05). The longitudinal coordinate of hip rotation center was improved from (3.02±0.84) cm before operation to (2.35±0.53) cm after operation (P<0.01). During the follow-up period, the Jumbo cup was well fixed without loosening and displacement, the acetabular cup had bone ingrowth in varying degrees, and no light transmission line and osteolysis around the acetabular cup were found. No complications such as infection and nerve injury occurred.@*CONCLUSION@#The method of reconstructing acetabular bone defect with porous tantalum Jumbo cup is simple and easy, the early stability of acetabulum is good, and the short-term follow-up effect is good.


Asunto(s)
Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera , Estudios de Seguimiento , Prótesis de Cadera , Porosidad , Falla de Prótesis , Reoperación , Estudios Retrospectivos , Tantalio , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA