Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Maxillofacial Plastic and Reconstructive Surgery ; : 6-2022.
Artículo en Inglés | WPRIM | ID: wpr-969129

RESUMEN

Background@#No studies have compared the outcomes of direct perineurial suture with vein graft cuff repair and indirect collagen allograft repair of the lingual nerve following an injury. Therefore, we evaluated and compared the outcomes of each over a 1-year observation period. We retrospectively assessed 20 patients who had undergone microneurosurgical repair of unilateral lingual nerve injuries at the Wakayama Medical University Hospital between May 2015 and March 2019. We utilized two different methods for lingual nerve repair, i.e., direct perineurial repair with a vein graft cuff and interpositional collagen allograft repair. Sensory and taste function in the lingual nerve were preoperatively evaluated using a static two-point discrimination test, superficial pain/tactile sensation test, tests for the pressure pain threshold (Semmens-Weinstein monofilament), test for thermal discrimination hot and cold sensation, and a taste discrimination test. These tests were performed again at 6 and 12 months postoperatively. @*Results@#Compared to the preoperative conditions, all patients showed improved sensory reactions. Functional sensory recovery outcomes were defined by Pogrel’s criteria, Medical Research Council Scale grades, and functional sensory recovery. In each group, all patients improved after the operation. However, the operation time was significantly shorter for an interpositional collagen allograft repair as compared to that for a direct perineurial repair with a vein graft cuff. @*Conclusions@#There were no statistically significant differences between the two repair Methods, except for the operation time. Both methods led to satisfactory results for all criteria. From an economic point of view, direct perineurial repair with a vein graft cuff is meaningful; however, the esthetic effect on the donor site should be considered. Conversely, interpositional collagen allograft repair has the advantage of a greatly shortened operation time.

2.
Korean Journal of Radiology ; : 217-226, 2009.
Artículo en Inglés | WPRIM | ID: wpr-101659

RESUMEN

OBJECTIVE: We wanted to evaluate the performance of prospective electrocardiogram (ECG)-gated axial scans for assessing coronary stents as compared with retrospective ECG-gated helical scans. MATERIALS AND METHODS: As for a vascular model of the coronary artery, a tube of approximately 2.5-mm inner diameter was adopted and as for stents, three (Bx-Velocity, Express2, and Micro Driver) different kinds of stents were inserted into the tube. Both patent and stenotic models of coronary artery were made by instillating different attenuation (396 vs. 79 Hounsfield unit [HU]) of contrast medium within the tube in tube model. The models were scanned with two types of scan methods with a simulated ECG of 60 beats per minute and using display field of views (FOVs) of 9 and 18 cm. We evaluated the in-stent stenosis visually, and we measured the attenuation values and the diameter of the patent stent lumen. RESULTS: The visualization of the stent lumen of the vascular models was improved with using the prospective ECG-gated axial scans and a 9-cm FOV. The inner diameters of the vascular models were underestimated with mean measurement errors of -1.10 to -1.36 mm. The measurement errors were smaller with using the prospective ECG-gated axial scans (Bx-Velocity and Express2, p < 0.0001; Micro Driver, p = 0.0004) and a 9-cm FOV (all stents: p < 0.0001), as compared with the other conditions, respectively. The luminal attenuation value was overestimated in each condition. For the luminal attenuation measurement, the use of prospective ECG-gated axial scans provided less measurement error compared with the retrospective ECG-gated helical scans (all stents: p < 0.0001), and the use of a 9-cm FOV tended to decrease the measurement error. CONCLUSION: The visualization of coronary stents is improved by the use of prospective ECG-gated axial scans and using a small FOV with reduced blooming artifacts and increased spatial resolution.


Asunto(s)
Medios de Contraste , Angiografía Coronaria , Estenosis Coronaria , Vasos Coronarios , Electrocardiografía/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Modelos Cardiovasculares , Variaciones Dependientes del Observador , Fantasmas de Imagen , Intensificación de Imagen Radiográfica/métodos , Stents , Tomografía Computarizada Espiral/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA