Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Artículo en Inglés | WPRIM | ID: wpr-739953

RESUMEN

Lingual nerve injury is a rare complication of general anesthesia. The causes of lingual nerve injury following general anesthesia are multifactorial; possible mechanisms may include difficult laryngoscopy, prolonged anterior mandibular displacement, improper placement of the oropharyngeal airway, macroglossia and tongue compression. In this report, we have described a case of bilateral lingual nerve injury that was associated with orotracheal intubation for open reduction and internal fixation of the left distal radius fracture in a 61-year-old woman. In this case, early treatment with dexamethasone effectively aided the recovery of the injured lingual nerve.


Asunto(s)
Femenino , Humanos , Persona de Mediana Edad , Anestesia General , Dexametasona , Intubación , Laringoscopía , Traumatismos del Nervio Lingual , Nervio Lingual , Macroglosia , Fracturas del Radio , Lengua
2.
Kosin Medical Journal ; : 137-143, 2013.
Artículo en Coreano | WPRIM | ID: wpr-194267

RESUMEN

OBJECTIVES: This study was investigated the recovery characteristics of propofol-remifentanil and sevoflurane-remifentanil anesthesia for total thyroidectomy. METHODS: Eighty patients in ASA physical status 1 and 2 scheduled for total thyroidectomy were allocated randomly to either group P (n = 40) or group S (n = 40). Anesthesia was maintained with remifentanil effect site concentration (Ce) 1-3 ng/mL and propofol Ce 2-4 microg/mL in the group P, and was maintained with remifentanil Ce 1-3 ng/mL and sevoflurane 1.5-2% in the group S. Blood pressure, heart rate, and bispectral (BIS) index were measured during perioperative period. The times from discontinuance of anesthetic agent to eye opening, to extubation, and to stating name were measured. Postoperative complications were evaluated. RESULTS: There were no significant differences between group P and S on the blood pressure, heart rate, and recovery time. BIS index of group P showed lower than that of group S during operation (P < 0.05). The incidences of side effects were similar in the two groups, though the incidence of nausea was higher in the group S (P < 0.05). CONCLUSIONS: Propofol-remifentanil anesthesia was more advantageous than sevoflurane-remifentanil anesthesia for thyroidectomy in view of side effect incidences.


Asunto(s)
Humanos , Anestesia , Presión Sanguínea , Frecuencia Cardíaca , Incidencia , Náusea , Periodo Perioperatorio , Complicaciones Posoperatorias , Propofol , Tiroidectomía
3.
Safety and Health at Work ; : 130-139, 2012.
Artículo en Inglés | WPRIM | ID: wpr-8702

RESUMEN

OBJECTIVES: The purpose of this study is to evaluate the tire manufacturing work environments extensively and to identify workers' exposure to hazardous substances in various work processes. METHODS: Personal air sampling was conducted to measure polycyclic aromatic hydrocarbons, carbon disulfide, 1,3-butadiene, styrene, methyl isobutyl ketone, methylcyclohexane, formaldehyde, sulfur dioxide, and rubber fume in tire manufacturing plants using the National Institute for Occupational Safety Health Manual of Analytical Methods. Noise, carbon monoxide, and heat stress exposure were evaluated using direct reading instruments. Past concentrations of rubber fume were assessed using regression analysis of total particulate data from 2003 to 2007, after identifying the correlation between the concentration of total particulate and rubber fume. RESULTS: Workers were exposed to rubber fume that exceeded 0.6 mg/m3, the maximum exposure limit of the UK, in curing and production management processes. Forty-seven percent of workers were exposed to noise levels exceeding 85 dBA. Workers in the production management process were exposed to 28.1degrees C (wet bulb globe temperature value, WBGT value) even when the outdoor atmosphere was 2.7degrees C (WBGT value). Exposures to other substances were below the limit of detection or under a tenth of the threshold limit values given by the American Conference of Governmental Industrial Hygienists. CONCLUSION: To better classify exposure groups and to improve work environments, examining closely at rubber fume components and temperature as risk indicators in tire manufacturing is recommended.


Asunto(s)
Humanos , Aerosoles , Atmósfera , Butadienos , Disulfuro de Carbono , Monóxido de Carbono , Ciclohexanos , Formaldehído , Sustancias Peligrosas , Calor , Límite de Detección , Metil n-Butil Cetona , Ruido , Exposición Profesional , Salud Laboral , Hidrocarburos Policíclicos Aromáticos , Goma , Estireno , Dióxido de Azufre , Valores Limites del Umbral
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA