Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Arch. cardiol. Méx ; Arch. cardiol. Méx;89(2): 172-180, Apr.-Jun. 2019. tab, graf
Artículo en Español | LILACS-Express | LILACS | ID: biblio-1142179

RESUMEN

Resumen Introducción y objetivos: En algunos centros el tamiz cardíaco no se realiza con la justificación de no tener el oxímetro adecuado. Comparamos la efectividad de dos marcas de oxímetros para realizarlo. Métodos: En los neonatos a término del Servicio de alojamiento conjunto del Hospital General de Occidente en Zapopan Jalisco México de mayo a noviembre del 2018 se realizó tamiz cardíaco según las guías de la Academia Americana de Pediatría con dos oxímetros, el Masimo SET (aprobado por la FDA) y el ChoiceMMed, comparando su efectividad para la detección de cardiopatías congénitas críticas, el tiempo de toma y los falsos positivos. Resultados: En cada grupo se analizaron 1,022 pacientes; con el oxímetro Massimo SET se obtuvieron 83 pruebas positivas (8.12%) de las cuales 22 casos presentaron alguna cardiopatía (26.5%), lo que representa una sensibilidad del 100%, una especificidad del 93.9%, un valor predictivo positivo del 26.5% y un valor predictivo negativo del 100% (Odd Ratio [OR]: 0.73; IC 95%: 0.6-0.8). Con el oxímetro ChoiceMMed se obtuvieron 168 pruebas positivas (16.4%), de las cuales 22 casos presentaron alguna cardiopatía (13.09%), con una sensibilidad del 100%, una especificidad del 85.4%, un valor predictivo positivo del 13.09% y un valor predictivo negativo del 100% (OR: 0.86; IC 95%: 0.8-0.92). En cuanto al tiempo para realizar el tamiz cardíaco, la media en minutos del oxímetro Masimo SET fue 5.38 y del oxímetro ChoiceMMed fue 9.7 minutos. Conclusiones: El oxímetro ChoiceMMed presentó mayor cantidad de falsos positivos y mayor tiempo de realización del tamiz cardíaco en comparación al Masimo SET, sin embargo, ambos presentan un valor predictivo negativo del 100%, siendo igualmente útiles como método de detección de cardiopatías críticas.


Abstract Introduction and objectives: In some centers the pulse oximetry is not performed with the justification of lack of the adequate oximeter. We compared the effectiveness of two brands of oximeters to perform it. Methods: In neonates a term of the joint housing service of a Hospital General de Occidente in Zapopan Jalisco Mexico from May-November 2018, an examination of the characteristics of the American Academy of Pediatrics with both oximeters (ChoiceMMed and Masimo SET) was carried out, comparing the detection of critical congenital heart disease (CCC), time of intake and false positives. Results: In each group 1,022 patients were analyzed; with the Masimo SET oximeter 83 positive tests were obtained (8.12%), of which 22 cases had some heart disease (26.5%), which represents a sensitivity of 100%, specificity of 93.9%, positive predictive value of 26.5% and negative predictive value of 100% (OR: 0.73; 95% CI: 0.6-0.8). With the ChoiceMMed oximeter, 168 positive tests were obtained (16.4%), of which 22 cases had some heart disease (13.09%), with a sensitivity of 100%, specificity of 85.4%, positive predictive value of 13.09% and negative predictive value 100% (OR: 0.86; 95% CI: 0.8-0.92). Regarding the time to perform the cardiac sieve, the mean in minutes of the Masimo SET oximeter was 5.38 and the ChoiceMMed oximeter was 9.7 minutes. Conclusions: The ChoiceMMed oximeter contains a large number of false positives and a greater number of echocardiograms and comparatively longer cardiac screen printing with Masimo SET, however, both with a negative predictive value of 100% eliminating such excuses.

2.
Braz. j. microbiol ; Braz. j. microbiol;43(4): 1428-1435, Oct.-Dec. 2012. graf, tab
Artículo en Inglés | LILACS | ID: lil-665829

RESUMEN

The media claims for the consumption of natural resource-based food have gradually increased in both developing and developed countries. The interest in the safety of these products is partially due to the possible presence of toxigenic fungi acting as mycotoxin producers, such as aflatoxins produced during the secondary metabolism of Aspergillus flavus, A. parasiticus and A. nomius. Aflatoxins, mainly aflatoxin B1, are directly associated with liver cancer in human beings. This paper is aimed at evaluating the presence of aflatoxin B1 in a few vegetable drugs, dried plant extracts and industrialized products traded in 2010 in the city of Belo Horizonte, State of Minas Gerais, Brazil. The method used for the quantification of aflatoxin B1 was based on extraction through acetone:water (85:15), immunoaffinity column purification followed by separation and detection in high efficiency liquid chromatography. Under the conditions of analysis, the Limits of Detection and Quantification were 0.6 µg kg-1 and 1.0 µg kg-1respectively. The complete sets of analyses were carried out in duplicate. Aflatoxin B1 was noticed in a single sample (< 1.0 µg kg-1). The results revealed low aflatoxin B1contamination in the products under analysis. However, it is required to establish a broad monitoring program in order to obtain additional data and check up on the actual extension of contamination.


Asunto(s)
Humanos , Aflatoxina B1/análisis , Aflatoxina B1/metabolismo , /análisis , Extractos Vegetales/análisis , Técnicas In Vitro , Micotoxinas/análisis , Plantas Medicinales/metabolismo , Preparaciones de Plantas/análisis , Cromatografía Líquida de Alta Presión/métodos , Métodos , Métodos , Virulencia
3.
Sci. med ; 14(1): 24-31, 2004.
Artículo en Portugués | LILACS | ID: lil-445365

RESUMEN

O trabalho teve como objetivo investigar a associação do polimorfismo de inserção/ delegação do gene da enzima conversora de angiotensina (ECA) com a presença de infarto do miocárdio e a extensão da doença arterial coronariana (DAC). Na literatura o alelo D da ECA tem sido relacionado com o desenvolvimento de doenças cardiovasculares, porém os resultados dos estudos publicados permanecem controversos. A associação do genótipo DD da ECA com infarto do miocárdio tem sido inconstante e atualmente sugere-se que esta associação estaria limitada a certos grupos raciais. A população do estudo consistiu de pacientes masculinos com idade entre 35 e 70 anos e que foram submetidos a cateterismo cardíaco para investigação de DAC. Definiu-se como grupo caso os indivíduos com diagnóstico de DAC e como grupo controle os pacientes com coronárias normais ao exame. A extensão do envolvimento caronariano foi classificado de acordo com o número de artérias coronarianas que apresentavam estenoses moderada ou severa. A genotipagem foi realizada através da técnica de reação em cadeia da polimerase (PCR) e os fatores de risco clássicos para DAC avaliados através de questionário, exame físico e exames laboratoriais. Participaram do estudo 34 pacientes, sendo 19 casos e 15 controles. A média de idade foi de 56 anos, sem diferença significativa entre os grupos. Na amostra estudada o genótipo da ECA não esteve associado à idade, índice de massa corporal, dislipidemia, níveis de glicemia em jejum elevados, tabagismo e história de hipertensão ou tratamento anti-hipertensivo. Não houve associação significativa entre o genótipo DD da ECA e a presença de infarto do miocárdio (P = 0,257). Também não se evidenciou associação entre o genótipo DD da ECA e o grau de extensão da DAC (P = 0,355). A maior prevalência do Genótipo DD no grupo de pacientes com DAC, levanta a hipótese de que com o aumento do número da amostra poderemos obter dados mais consistentes.


Asunto(s)
Humanos , Masculino , Adulto , Persona de Mediana Edad , Enfermedad de la Arteria Coronaria , Infarto del Miocardio , Peptidil-Dipeptidasa A , Polimorfismo Genético , Reacción en Cadena de la Polimerasa
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA