Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Journal of the Korean Society for Microbiology ; : 233-243, 1999.
Artículo en Coreano | WPRIM | ID: wpr-128692

RESUMEN

To search the effective antisense oligonucleotide that inhibit the growth of Herpes simplex virus type 1 (HSV-1), six kinds of phosphorothioate oligodeoxynucleotides (S-ODNs) were synthesized and the antiviral activity was assessed by measuring cytopathic effect in Vero cells infected with HSV-1. Of the three dodecamer S-ODNs, cornplernentary to the translation initiation site of IE2 (AS2) and scrambled S-ODN (AS1) showed more significant antiherpetic activity than AS4 complementary to the IE4. Accordingly, the antiviral effect of dodecamer S-ODN was not specific. In contrast to the no inhibitory effect of sense strand S-ODN of ICP8 (AS6), two S-ODNs complementary to the translation initiation site of ICP8 (AS3) and that of IE1 (AS5) showed potent antiherpetic activity assessed in vitro HSV-1 virus yield assay. Antiherpetic effect of AS3 was decreased in proportion to the addition of AS6. The synthesis of viral protein ICPS and IE1 were inhibited in AS3 and AS5 treated HSV-1 infected Vero cells, respectively. These findings suggest that antiherpetic effect of AS3 is specifically mediated by targeting ICPS. S-ODNs had no effect on Vero cell viability. The data suggest that the 19-mer S-ODNs may be effective in antiviral chemotherapy.


Asunto(s)
Quimioterapia , Herpes Simple , Herpesvirus Humano 1 , Oligodesoxirribonucleótidos , Oligonucleótidos Fosforotioatos , Simplexvirus , Células Vero
2.
Journal of the Korean Academy of Family Medicine ; : 1500-1507, 1997.
Artículo en Coreano | WPRIM | ID: wpr-70277

RESUMEN

BACKGROUND: Recently, it is substituted automatic sphygmomanometer for mercury sphygmomanometer. But it seems to be insufficient for data of its accuracy. A sample accurate automatic sphygmomanometer could have an important role in the management of hypertension. The aim of this study is to assess the accuracy of the automatic sphygmomanometer that is used common practice and at home. METHODS: We collected 247 patients who visited the department of Famiiy Practice of Taegu medical center from April to August 1996. BP was measured sequentially same arm by standard device(mercury. sphygmomanometer), test device A(A&D TM-2650), test device B(seine SE-2000). We assessed the automatic sphygmomanometer according to the standards set out by the British Hypertension Society(BHS) protocol and the American Association for the Advancement of Medical Instrumentation(AAMI). These data were analysed using pearson' correlation and paired t-test. RESULTS: Test device A was highly correlated to mercury sphygmomanometer in systolic and diastolic BP(r=0.90, r=0.88). Also test device B was highly correlated to that(r=0.90, r=0.87). The mean difference between BP value obtained by the standard device and those obtained by the test device A were 0.59+/-7.66mmHg systole(mean+/-SD) and 3.83+/-6.43mmHg diast.ole, whereas the difference between the former and those obtained by the test device B were 1.70+/-7.99mmHg systole.and 5.58+/-6.38mmHg diastole. Comparing to standard device, there were a signifioant difference except systolic BP of test device A(P<0.05). According to the criteria of the AAMI, the diastolic BP of test device B was not enough and according to the criteria of the BHS, the diastolic BP of both test device were not enough. CONCLUSIONS: Both test device were highly correlated to mercury sphygmomanometer. But according to the criteria of the BHS and AAMI, there were not enough. Because the use of automatic sphygmomanometer was popularized, I think that further study will be required to assess of accuracy.


Asunto(s)
Humanos , Brazo , Presión Sanguínea , Diástole , Hipertensión , Esfigmomanometros
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA