Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Añadir filtros








Intervalo de año
1.
Braz. j. med. biol. res ; 28(10): 1113-6, Oct. 1995. graf
Artículo en Inglés | LILACS | ID: lil-161004

RESUMEN

The purpose of the present study was to determine the mechanical respiratory profile after the insertion of a catheter into the pleural cavity of anesthetized, paralyzed, mechanically ventilated rats, thus simulating the common use of chest tubes in clinical situations. Using the method of end-inflation occlusion during constant inspiratory flow in 7 adult Wistar rats, respiratory system, lung, and chest wall total resistance (0.353 +/- 0.058, 0.260 +/- 0.651, 0.092 +/- 0.012 (mean +/- SD) cmH2O.ml-1.s, respectively), viscous resistance (0.140 +/- 0.007, 0.100 +/- 0.007, 0.040 +/- 0.003 cmH2O.ml-1.s, respectively), and viscoelastic resistance (0.213 +/- 0.017, 0.160 +/- 0.022, 0.053 +/- 0.011 cmH2O.ml-1.s respectively) as well as respiratory system, lung and chest wall static elastance (4.51 +/- 0.27, 3.85...


Asunto(s)
Animales , Ratas , Mecánica Respiratoria/fisiología , Toracostomía , Resistencia de las Vías Respiratorias , Tubos Torácicos , Esófago/fisiología , Presión , Ratas Wistar , Toracostomía/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA