Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Braz. oral res. (Online) ; 35: e118, 2021. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO | ID: biblio-1350365

RESUMEN

Abstract: Biodentine in endodontic practice has been widely investigated, but comprehensive histological descriptions of degenerative and inflammatory responses are not covered in most of the studies that compare pulp capping materials. This study aimed to evaluate pulpal responses to mineral trioxide aggregate (MTA Angelus) and Biodentine, focusing on mineralized barrier formation and on inflammatory and degenerative events. 80 male Wistar rats were assigned to 5 groups, according to the materials used for pulp capping and coronal sealing (n=8 per group/period). The lower first molars were mechanically exposed, capped with either MTA or Biodentine, and restored with silver amalgam. In an additional test group, the teeth were capped and sealed with Biodentine. The teeth capped with gutta-percha and restored with silver amalgam served as positive control, whereas untreated teeth served as negative control. Pulpal responses and coronal sealing were evaluated after 14 or 21 days. Data was statistically analyzed by the Kruskal-Wallis and Dunn's post hoc tests (p<0.05). Biodentine and MTA presented satisfactory results, showing a milder inflammatory response (p<0.0001) and more pronounced formation of mineralized barrier (p<0.0001) compared to the teeth capped with gutta-percha. As a restorative material, Biodentine kept coronal sealing in only 37.5% of the samples. Biodentine showed favorable properties in vital pulp therapy, being similar to MTA. However, it was not effective in protecting dental pulp from microleakage during the experimental period.

2.
Int. arch. otorhinolaryngol. (Impr.) ; 24(3): 351-358, July-Sept. 2020.
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1134156

RESUMEN

Abstract Introduction Coronavirus disease 19 (COVID-19) is potentially the greatest global public health crisis of this century. This disease emerged as an outbreak of pneumonia of unknown cause in Wuhan, the capital city of the Hubei province in China, in December 2019. Otolaryngologists, head and neck surgeons and dentists are at an increased risk of occupational disease. Objective The present review summarizes currently published evidence of Covid-19 epidemiology, clinical characteristics, treatment and prevention. No proven effective treatments for this disease currently exist. Data Synthesis COVID-19 started from a zoonotic transmission event associated with a large seafood market that also traded in live wild animals, and it soon became clear that efficient person-to-person transmission was also occurring. Symptoms are varied, and not all patients develop all of them. Conclusion Social distancing seems to have been successful in several places in the world. However, this recommendation alone is not enough to contain the disease, and it is not a long-term solution. Large-scale testing by health professionals of representative samples of the population may give an estimate of the progression of the disease. Different treatments are under test and bring hope of a cure to the population. However, no current treatments (April 27, 2020) have been proven to be the key to success in the treatment of patients with COVID-19. Planetary health is a useful concept to understand the current drivers of this pandemic and to draw a roadmap for science and healthcare that may guide actions to fight economic depression and ensure a healthy recovery.

3.
Braz. oral res. (Online) ; 34: e039, 2020. tab, graf
Artículo en Inglés | LILACS, BBO | ID: biblio-1100935

RESUMEN

Abstract To compare the shaping ability of different single-file systems in the preparation of mesial curved canals of mandibular molars using micro-CT technology. Fifteen mesial roots of mandibular molars with two independent and curved canals (n = 30) were selected, scanned at a resolution of 26.7 μm anatomically matched, and distributed into three groups (n = 10), according to the preparation system: WaveOne 25.08, Reciproc 25.08, and OneShape 25.06. A final micro-CT scanning was performed, data sets were registered with their respective counterparts, and compared regarding the three-dimensional (volume, surface area, and structure model index - SMI) and two-dimensional (perimeter, area, roundness, major and minor diameters) parameters, as well as, canal transportation, using ANOVA and post hoc Tukey tests (α = 5%). Overall, no difference was observed between groups regarding area, perimeter, volume, surface area, and canal transportation (p > 0.05). Within group, no canal transportation was significantly higherobserved in the apical third (0.10 ± 0.05 mm) compared to coronal (0.08±0.040 mm) and middle (0.07 ± 0.03 mm) thirds (p < 0.05). Structure model index (SMI) was statistically higher after preparation with OneShape instrument (0.36 ± 0.26) compared to other systems (p < 0.05). Within the parameters of this study, similar shaping ability was observed in the preparation of mesial curved root canals of mandibular molars with Reciproc, OneShape and WaveOne systems.


Asunto(s)
Humanos , Preparación del Conducto Radicular/instrumentación , Cavidad Pulpar/anatomía & histología , Cavidad Pulpar/diagnóstico por imagen , Valores de Referencia , Ensayo de Materiales , Análisis de Varianza , Estadísticas no Paramétricas , Instrumentos Dentales , Diseño de Equipo , Microtomografía por Rayos X/métodos , Diente Molar/anatomía & histología
4.
Braz. oral res. (Online) ; 31: e72, 2017. tab
Artículo en Inglés | LILACS | ID: biblio-952078

RESUMEN

Abstract To assess the physicochemical properties of AH Plus, GuttaFlow 2, GuttaFlow BioSeal, and MM Seal, five samples of each root canal sealer were evaluated to determine their setting time (ST), dimensional change (DC), solubility (SL), flow (FL), and radiopacity (RD) according to American National Standards Institute/American Dental Association (ANSI/ADA) Specification 57. The distilled and deionized water obtained from the SL test were subjected to atomic absorption spectrometry to observe the presence of Ca2+, K+, and Na+ ions. Statistical analysis was performed by using one-way ANOVA and Tukey-Kramer tests (p < 0.05). The following results were obtained: ST (min) (AH Plus 463.6 ± 13.22; GuttaFlow 2 24.35 ± 2.78; GuttaFlow Bioseal 17.4 ± 0.55; MM Seal 47.60 ± 4.39), DC (%) (AH Plus 0.06 ± 0.12; GuttaFlow 2 −26.06 ± 1.24; GuttaFlow Bioseal 2.10 ± 1.47; MM Seal 8.47 ± 2.41), SL (%) (AH Plus 0.41 ± 0.21; GuttaFlow 2 5.13 ± 4.11; GuttaFlow Bioseal 3.03 ± 1.05; MM Seal 0.94 ± 0.17), FL (mm) (AH Plus 36.42 ± 0.40; GuttaFlow 2 36.44 ± 0.05; GuttaFlow Bioseal 35.4 ± 0.03; MM Seal 52.75 ± 0.60), and RD (mmAl) (AH Plus 7.52 ± 1.59; GuttaFlow 2 6.85 ± 0.14; GuttaFlow Bioseal 7.02 ± 0.18; MM Seal 3.32 ± 0.90). ST, DC, SL, FL, and RD showed statistical differences among the root canal sealers (p < 0.05). As AH Plus showed the lowest DC and SL values (p < 0.05), the findings indicate that this sample is the only sealer conforming to ANSI/ADA standards.


Asunto(s)
Materiales de Obturación del Conducto Radicular/química , Siliconas/química , Dimetilpolisiloxanos/química , Resinas Epoxi/química , Gutapercha/química , Valores de Referencia , Solubilidad , Espectrofotometría Atómica , Propiedades de Superficie , Factores de Tiempo , Ensayo de Materiales , Análisis de Varianza , Estadísticas no Paramétricas , Combinación de Medicamentos
5.
Braz. dent. j ; 27(6): 657-663, Nov.-Dec. 2016. tab, graf
Artículo en Inglés | LILACS | ID: biblio-828069

RESUMEN

Abstract Satisfactory biological behavior is a necessary requirement for clinical application of endodontic materials. In this study, the connective tissue responses to silicone (GuttaFlow 2), epoxy resin (AH Plus) and zinc oxide and eugenol (Endofill) based sealers were compared. Twelve Wistar rats had polyethylene tubes (four per animal) containing one of the tested sealers and empty tubes (negative control) implanted in their subcutaneous tissue. The tubes were randomly placed 2 cm from the spine and at least 2 cm apart from one another. Tissue samples with implants were processed for histological analysis after 7 or 60 days (n=6 animals per period). Inflammatory cells, fibrous condensation and abscess were scored according to their intensity. Friedman, followed by Dunn's post hoc, was used to compare sealers. Differences between the two experimental periods were verified using Mann-Witney U test (p<0.05). At 7 days, most of the histological parameters showed no significant differences amongst groups. Endofill group scored higher than the others for giant cells (o<0.05) and promoted a greater number of samples presenting abscess formation. GuttaFlow 2 tended to show a less intense inflammatory infiltrate compared to the other materials. At 60 days, there were no significant differences between groups in most of the histological parameters evaluated. However, it was observed that Endofill scored higher for macrophages (p<0.05) compared to the control group, and GuttaFlow 2 tended to present lower scores than the others for neutrophils and abscess. GuttaFlow 2 showed proper biological behavior and should be considered adequate for clinical practice.


Resumo Um dos requisistos para a aplicação clínica de materiais endodônticos é apresentar comportamento biológico satisfatório. Neste estudo, as respostas do tecido conjuntivo a cimentos endodônticos à base de silicone (GuttaFlow 2), resina epóxica (AH Plus) e óxido de zinco e eugenol (Endofill) foram comparadas. Doze ratos Wistar tiveram tubos de polietileno (4 em cada animal) contendo um dos materiais e tubos vazios (controle negativo) implantados no tecido conjuntivo subcutâneo. Os tubos foram randomicamente posicionados pelo menos 2 cm distantes entre si e da espinha dorsal do animal. Amostras de tecido contendo os implantes foram processadas para análise histológica após 7 e 60 dias (n=6 animais por período). Células inflamatórias, condensação fibrosa e formação de abscesso foram classificadas em escores de acordo com sua intensidade. O teste Friedman, seguido por post hoc de Dunn, foi empregado para comparar os cimentos. O teste de Mann-Witney U foi empregado para verificar diferenças entre os períodos experimentais em cada grupo (p<0,05). Após 7 dias, a maior parte dos parâmetros histológicos não mostrou diferenças estatísticas entre os grupos. O cimento Endofill promoveu escores mais altos que os outros materiais para a variável células gigantes (p<0,05), além de apresentar um maior número de amostras com formação de abscesso. O GuttaFlow 2 tendeu a apresentar infiltrado inflamatório menos intenso comparado aos outros materiais. Após 60 dias, não houve diferenças estatisticamente significantes entre os grupos na maioria dos parâmetros avaliados. Entretanto, observou-se que o EndoFill apresentou escores mais altos para os macrófagos em comparação ao controle (p<0,05) e que o GuttaFlow 2 apresentou tendência a escores mais baixos que os demais materiais para as variáveis neutrófilos e abscesso. O GuttaFlow 2 apresentou propriedades biológicas apropriadas e pode ser considerado adequado para a prática clínica.


Asunto(s)
Animales , Masculino , Ratas , Materiales de Obturación del Conducto Radicular , Siliconas , Ratas Wistar
6.
Braz. oral res. (Online) ; 30(1): e18, 2016. tab, graf
Artículo en Inglés | LILACS | ID: biblio-951962

RESUMEN

Abstract The aim of this study was to evaluate whether the modification in the silver component is capable of providing GuttaFlow 2 with antibacterial activity against Enterococcus faecalis compared with epoxy resin-based (AH Plus) and zinc oxide and eugenol-based (Endofill) sealers. The antibacterial activity was evaluated using a reference strain of E. faecalis (ATCC 29212). Freshly mixed sealers were subjected to the agar diffusion test (ADT), while the direct contact test (DCT) was performed after materials setting. ADT results were obtained through measurements, in millimeters, of the inhibition zones promoted by the materials, using a digital caliper. In DCT, values of CFU/mL promoted by the three sealers were compared in three experimental periods (1 min, 1 h, and 24 h). The data were analyzed using Kruskal-Wallis and Dunn post-hoc tests (p < 0.05). In both ADT and DCT, GuttaFlow 2 presented no effect against E. faecalis, while Endofill and AH Plus showed similar inhibition zones. Endofill was the only material capable of reducing bacterial growth in DCT. In conclusion, modifications in the silver particle of GuttaFlow 2 did not result in a sealer with antibacterial effect against E. faecalis.


Asunto(s)
Materiales de Obturación del Conducto Radicular/farmacología , Plata/farmacología , Enterococcus faecalis/efectos de los fármacos , Dimetilpolisiloxanos/farmacología , Resinas Epoxi/farmacología , Gutapercha/farmacología , Antibacterianos/farmacología , Tamaño de la Partícula , Materiales de Obturación del Conducto Radicular/química , Siliconas/farmacología , Siliconas/química , Plata/química , Factores de Tiempo , Ensayo de Materiales , Recuento de Colonia Microbiana , Reproducibilidad de los Resultados , Estadísticas no Paramétricas , Dimetilpolisiloxanos/química , Combinación de Medicamentos , Resinas Epoxi/química , Gutapercha/química , Antibacterianos/química
7.
Braz. oral res. (Online) ; 30(1): e19, 2016. tab, graf
Artículo en Inglés | LILACS | ID: biblio-951989

RESUMEN

Abstract The present study aims to verify the effect of ozone gas (OZY® System) and high frequency electric pulse (Endox® System) systems on human root canals previously contaminated with Escherichia colilipopolysaccharide (LPS). Fifty single-rooted teeth had their dental crowns removed and root lengths standardized to 16 mm. The root canals were prepared up to #60 hand K-files and sterilized using gamma radiation with cobalt 60. The specimens were divided into the following five groups (n = 10) based on the disinfection protocol used: OZY® System, one 120-second-pulse (OZY 1p); OZY® System, four 24-second-pulses (OZY 4p); and Endox® System (ENDOX). Contaminated and non-contaminated canals were exposed only to apyrogenic water and used as positive (C+) and negative (C-) controls, respectively. LPS (O55:B55) was administered in all root canals except those belonging to group C-. After performing disinfection, LPS samples were collected from the canals using apyrogenic paper tips. Limulus Amoebocyte Lysate (LAL) was used to quantify the LPS levels, and the data obtained was analyzed using one-way ANOVA. The disinfection protocols used were unable to reduce the LPS levels significantly (p = 0.019). The use of ozone gas and high frequency electric pulses was not effective in eliminating LPS from the root canals.


Asunto(s)
Humanos , Oxidantes Fotoquímicos , Ozono , Lipopolisacáridos/análisis , Cavidad Pulpar/microbiología , Electrocoagulación/métodos , Endotoxinas/análisis , Escherichia coli , Factores de Tiempo , Distribución Aleatoria , Reproducibilidad de los Resultados , Análisis de Varianza , Preparación del Conducto Radicular , Prueba de Limulus
8.
Braz. dent. j ; 26(3): 228-233, May-Jun/2015. tab, graf
Artículo en Inglés | LILACS | ID: lil-751863

RESUMEN

This study aimed to evaluate histologically the effect of irrigation with 400 ppm Sterilox, 2% and 5% sodium hypochlorite (NaOCl), with and without photo-activated therapy (PAD), in a single-visit root canal treatment of dog's teeth with apical periodontitis (AP). Ten dogs were randomly divided into two groups (n=5): with and without PAD, and the root canals into four subgroups, according to the irrigating solution: SX (400 ppm Sterilox), SH2 (2% NaOCl), SH5 (5% NaOCl) and SS (saline solution) as positive control. A total of 134 root canals were opened and left exposed to the oral environment for 14 days and then sealed for 60 days for AP induction. Then, root canals were treated according to each proposed disinfecting protocol and filled in the same session. After 120 days, the dogs were euthanized and the periapical inflammatory events were evaluated under light microscopy. Qualitative data were submitted to Kruskal-Wallis and Mann-Whitney tests (α=0.05). PAD did not produce significant differences in the scores for apical inflammation when used after chemo-mechanical preparation (p>0.05). The irrigating solutions SX, SH2 and SH5 without PAD were statistically different from SS (p<0.05) that presented the greatest scores for apical inflammation. PAD did not show any additional effect for the treatment of root canals with pulp necrosis and AP in a single visit and 400 ppm Sterilox may be considered an alternative to NaOCl in root canal treatment.


Este estudo realizou uma avaliação histológica do efeito das soluções irrigadoras Sterilox 400 ppm e hipoclorito de sódio (NaOCl) a 2% e 5%, com e sem a terapia fotodinâmica (PAD), na endodontia em sessão única de dentes de cães associados a lesões periapicais (APs). Dez cães foram divididos de forma randomizada em dois grupos (n=5): com e sem PAD, e os canais radiculares em quatro subgrupos, de acordo com a solução irrigadora utilizada: SX (Sterilox 400 ppm), SH2 (NaOCl 2%), SH5 (NaOCl 5%) e SS (solução salina) como controle positivo. Cento e trinta e quatro canais foram abertos e deixados expostos ao meio oral por 14 dias e depois selados por 60 dias para a indução de APs. Na sequência, os canais foram tratados de acordo com cada protocolo de desinfecção proposto e obturados na mesma sessão. Após 120 dias, os cães foram mortos e os eventos inflamatórios periapicais foram avaliados em microscopia óptica. Os dados qualitativos foram analisados estatisticamente pelos testes Kruskal-Wallis e Mann-Whitney (α=0,05). A PAD, quando empregada após o preparo químico-mecânico, não promoveu diferenças significativas nos escores para inflamação apical (p>0,05). As soluções irrigadoras SX, SH2 e SH5 sem PAD apresentaram diferenças estatísticas do grupo SS (p<0,05) que apresentou os maiores escores para inflamação apical. A PAD não apresentou efeito adicional na endodontia em sessão única dos canais com necrose pulpar associados a lesão apical e a solução irrigadora Sterilox 400 ppm pode ser considerada uma alternativa ao NaOCl na terapia endodôntica.


Asunto(s)
Animales , Perros , Peróxido de Hidrógeno , Fototerapia , Irrigantes del Conducto Radicular , Tratamiento del Conducto Radicular , Hipoclorito de Sodio
9.
Braz. dent. j ; 26(3): 288-291, May-Jun/2015. graf
Artículo en Inglés | LILACS | ID: lil-751872

RESUMEN

This study evaluated the bond strength of root-end filling materials to root-end cavities using a new methodology. Twenty maxillary central incisors were subjected to biomechanical preparation (#80 hand file) and sectioned transversally 2 mm short of the apex and 4 mm coronally to this point. The root cylinders were embedded in acrylic resin and positioned at 45° to the horizontal plane for preparation of root-end cavities with a diamond ultrasonic retrotip. Two groups (n=10) were formed according to the root-end filling material: MTA and Super EBA. A gutta-percha cone (#80) was tug-backed at the limit between the canal and the root-end cavity. The cavity was filled and the gutta-percha cone was removed after complete setting of the sealer. The specimens were placed in an Instron machine with the root-end filling turned downwards. The push-out shaft was inserted in the space previously occupied by the gutta-percha cone and run at a crosshead speed of 1.0 mm/min for pushing out the root-end filling material. Data were analyzed by ANOVA (α=5%). Super EBA (6.03±1.31) presented higher bond strength (MPa) than MTA (1.81±0.45) (p>0.05). There was a predominance of cohesive failures for Super EBA and mixed for MTA. The protocol of specimen preparation is effective and introduces a specific methodology for assessing bond strength of root-end filling materials to dentin. Among the materials, Super EBA presented the highest bond strength.


Este estudo avaliou a resistência de união de materiais retrobturadores a cavidades retrógradas, usando uma nova metodologia. Vinte incisivos centrais superiores foram submetidos ao preparo biomecânico (lima manual #80) e seccionadas transversalmente a 2 mm do ápice e a 4 mm do primeiro corte. Os cilindros de raízes foram incluídos em resina acrílica e posicionado a 45° em relação ao plano horizontal para confecção das retrocavidades com ponta ultrassônica diamantada. Dois grupos (n = 10) foram formados de acordo com os cimentos utilizados: MTA e Super EBA. Um cone de guta-percha (#80) foi travado no limite da retrocavidade com o canal radicular. A retrocavidade foi preenchida e, após o tempo de endurecimento do cimento utilizado, o cone de guta-percha foi removido. Os espécimes foram fixados na máquina universal de ensaios Instron com a retrobturação voltada para baixo. A haste empregada para pressionar o cimento retrobturador no teste de push-out foi inserida no espaço anteriormente ocupado pela guta-percha e acionada com velocidade de cruzeta de 1,0 mm/min, para extrusão do material retroburador. Os dados foram analisados por meio do teste ANOVA (α=5%). O cimento Super EBA (6,03 ± 1,31) apresentou maior resistência de união (MPa) comparado ao cimento MTA (1,81 ± 0,45) (p> 0,05). Houve predomínio de falhas coesivas para o cimento Super EBA e falhas mistas para o MTA. O protocolo de preparação das amostras é eficaz e apresenta uma metodologia específica para avaliação da resistência de união de materiais retrobturadores à dentina. Dentre os materiais testados, o cimento Super EBA apresentou a maior resistência de união.


Asunto(s)
Humanos , Ensayo de Materiales , Materiales de Obturación del Conducto Radicular , Técnicas In Vitro , Incisivo
10.
Braz. dent. j ; 25(5): 420-424, Sep-Oct/2014. tab
Artículo en Inglés | LILACS | ID: lil-731056

RESUMEN

The present study aimed to evaluate the influence of the following irrigating solutions on the microhardness of root canal dentin: 2% sodium hypochlorite (2NaOCl), 5% sodium hypochlorite (5NaOCl), super-oxidized water (400 ppm Sterilox - Sx) and 17% EDTA (E). Eighty roots from bovine incisors were randomly divided into 8 groups (n=10): 2NaOCl, 5NaOCl, Sx, and 2NaOCl + E, 5NaOCl + E, Sx + E (associated with E as final irrigant for 5 min), E solely and distilled water (dH2O) as the negative control. Root canal preparation was performed by hand instruments, using one of the irrigation protocols for 30 min. Then, 5 mm of the cervical root third were cut out from each sample and subjected to the Vickers microhardness test, at two points, one at approximately 500-1000 µm from the root canal lumen (distance 1), and the other at approximately 500-1000 µm from the external root surface (distance 2). Data were analyzed by Wilcoxon and Kruskal-Wallis tests at 5% significance level. Microhardness values at distance 1 were significantly lower than those at distance 2 for all groups, except 5NaOCl and 5NaOCl + E groups (p>0.05). EDTA showed the lowest microhardness values. However, no statistically significant difference was detected among groups at distance 1 and EDTA was significantly different only from Sx at distance 2. In conclusion, all tested solutions showed lower microhardness at the most superficial root canal dentin layer compared to the one found near the external root surface, except 5NaOCl and 5NaOCl + E; EDTA promoted lower microhardness values in comparison to Sterilox at this site.


O presente estudo teve como objetivo avaliar a influência das seguintes soluções irrigadoras na microdureza da dentina do canal radicular: hipoclorito de sódio a 2% (NaOCl2), hipoclorito de sódio a 5% (NaOCl5), água superoxidada (Sterilox(r) 400 ppm - Sx) e EDTA a 17% (E). Oitenta raízes de incisivos bovinos foram divididas aleatoriamente em 8 grupos (n=10): NaOCl2, NaOCl5, Sx e NaOCl2 + E, NaOCl5 + E, Sx + E (associados ao E como irrigante final por 5 min), E isolado e água destilada (H2Od), como controle negativo. O preparo dos canais radiculares foi realizado com instrumentos manuais, usando um dos protocolos de irrigação por 30 min. A seguir, 5 mm do terço cervical de cada amostra foram cortados perpendicularmente e submetidos ao teste de microdureza de Vickers, em dois pontos, um aproximadamente 500-1000 µm da luz do canal radicular (distância 1), e o outro aproximadamente 500-1000 µm da superfície externa da raiz (distância 2). Os dados foram analisados pelos testes de Wilcoxon e Kruskal-Wallis com um nível de significância de 5%. Os valores de microdureza na distância 1 foram significativamente menores do que na distância 2 para todos os grupos, exceto NaOCl5 e NaOCl5 +E (p>0,05). O EDTA mostrou os menores valores de microdureza. No entanto, não foi detectada diferença estatisticamente significativa entre os grupos na distância 1 e o EDTA foi significativamente diferente apenas do Sx na distância 2. Pode-se concluir que todas as soluções testadas mostraram menor microdureza na camada de dentina mais superficial do canal radicular em comparação aos valores encontrados próximo à superfície radicular externa, exceto NaOCl5 e NaOCl5 + E; o EDTA promoveu menor microdureza em comparação ao Sterilox(r) neste ponto.


Asunto(s)
Humanos , Antiinflamatorios no Esteroideos/farmacología , Antineoplásicos/farmacología , Carcinoma de Células Escamosas/tratamiento farmacológico , Neoplasias de la Boca/tratamiento farmacológico , Receptores Citoplasmáticos y Nucleares/metabolismo , Sulindac/análogos & derivados , Sulindac/farmacología , Factores de Transcripción/metabolismo , Apoptosis/efectos de los fármacos , Carcinoma de Células Escamosas/genética , Carcinoma de Células Escamosas/metabolismo , Ciclo Celular/efectos de los fármacos , División Celular/efectos de los fármacos , Inhibidores de la Ciclooxigenasa/farmacología , Cartilla de ADN/química , Citometría de Flujo , Técnicas para Inmunoenzimas , Isoenzimas/metabolismo , Proteínas de la Membrana , Neoplasias de la Boca/genética , Neoplasias de la Boca/metabolismo , Oligonucleótidos Antisentido/farmacología , Prostaglandina-Endoperóxido Sintasas/metabolismo , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , ARN Mensajero/metabolismo , Células Tumorales Cultivadas/efectos de los fármacos , Regulación hacia Arriba
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA