Korean Journal of Nephrology ; : 732-735, 2007.
Artículo en Inglés | WPRIM | ID: wpr-15394

RESUMEN

With the development of the Tenckhoff catheter and subsequent Trochar device for percutaneous placement, a bed-side approach for peritoneal dialysis (PD) catheter insertion has been frequently used by nephrologists. Bleeding complications resulting from PD catheter placement are infrequent and massive bleeding by the rupture of inferior epigastric artery is very rare. We report a case of massive intra-abdominal hematoma caused by traumatic rupture of inferior epigastric artery during percutaneous placement of PD catheter.


Asunto(s)
Catéteres , Arterias Epigástricas , Hematoma , Hemorragia , Fallo Renal Crónico , Diálisis Peritoneal , Diálisis Peritoneal Ambulatoria Continua , Recto del Abdomen , Rotura