Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Artículo en Inglés | WPRIM | ID: wpr-148191

RESUMEN

Optical coherence tomography (OCT) is an optical analog of intravascular ultrasound (IVUS) that can be used to examine the coronary arteries and has 10-fold higher resolution than IVUS. Based on polarization properties, OCT can differentiate tissue characteristics (fibrous, calcified, or lipid-rich plaque) and identify thin-cap fibroatheroma. Because of the strong attenuation of light by blood, OCT systems required the removal of blood during OCT examinations. A recently developed frequency-domain OCT system has a faster frame rate and pullback speed, making the OCT procedure more user-friendly and not requiring proximal balloon occlusion. During percutaneous coronary intervention (PCI), OCT can provide detailed information (dissection, tissue prolapse, thrombi, and incomplete stent apposition [ISA]). At follow-up examinations after stent implantation, stent strut coverage and ISA can be assessed. Several OCT studies have demonstrated delayed neointimal coverage following drug-eluting stent (DES) implantation vs. bare metal stent (BMS) placement. While newer DESs promote more favorable vascular healing, the clinical implications remain unknown. Recent OCT studies have provided insights into restenotic tissue characteristics; DES restenotic morphologies differ from those with BMSs. OCT is a novel, promising imaging modality; with more in-depth assessments of its use, it may impact clinical outcomes in patients with symptomatic coronary artery disease.


Asunto(s)
Humanos , Angioplastia Coronaria con Balón/efectos adversos , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/patología , Reestenosis Coronaria/etiología , Vasos Coronarios/patología , Valor Predictivo de las Pruebas , Índice de Severidad de la Enfermedad , Stents , Tomografía de Coherencia Óptica , Resultado del Tratamiento , Ultrasonografía Intervencional
2.
Chinese Medical Journal ; (24): 503-507, 2008.
Artículo en Inglés | WPRIM | ID: wpr-287703

RESUMEN

<p><b>BACKGROUND</b>Optical coherence tomography (OCT) is a new imaging modality with resolution of approximately 10 microm and can be employed to visualize intracoronary characteristics. Sirolimus-eluting stents (SES) are susceptible to late thrombosis due to delayed re-endothelialization over the stent struts, which may result in acute myocardial infarction or death. This study was designed to evaluate the re-endothelialization and neointimal coverage of SES with OCT 6 months and 12 months after implantation.</p><p><b>METHODS</b>A total of 36 patients enrolled in the study underwent OCT examination 6 months (17 patients) and 12 months (19 patients) after SES implantation. The strut apposition to the vessel wall and neointimal coverage on SES struts were evaluated by OCT.</p><p><b>RESULTS</b>Forty-six SES and 6561 struts were analyzed. At 6 months, 3041 struts (98.7%) were well-apposed and 39 struts (1.3%) were malapposed. At 12 months, 3434 struts (98.6%) were well-apposed and 47 struts (1.4%) were malapposed. Furthermore, only 4 SES at 6 months (18.2%) and 10 SES at 12 months (41.7%) were fully covered by neointimal growth. The average neointimal thicknesses covering the analyzed struts at 6 months and 12 months were (42+/-28) microm and (88+/-32) microm, respectively. There were 1989 struts at 6 months (72.1%) and 1461 struts at 12 months (45.6%) with neointimal thickness <100 microm.</p><p><b>CONCLUSIONS</b>OCT was able to visualize the strut apposition to the vessel wall and neointimal coverage on SES struts. At 6-month and 12-month follow-up examinations most struts were covered with thin neointima, but few of the entire SES showed full coverage. To prevent late-stent thrombosis in the presence of uncovered stent struts, longer dual antiplatelet drugs therapy should be recommended.</p>


Asunto(s)
Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Angioplastia Coronaria con Balón , Stents Liberadores de Fármacos , Estudios de Seguimiento , Sirolimus , Factores de Tiempo , Tomografía de Coherencia Óptica , Métodos , Túnica Íntima , Patología , Ultrasonografía Intervencional
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA