Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Añadir filtros








Intervalo de año
1.
Artículo en Inglés | IMSEAR | ID: sea-89725

RESUMEN

BACKGROUND: The availability of sensitive and specific assays for evaluation of the thyroid axis has allowed definition of thyroid disorders at subclinical stage. This has almost obviated the use of thyrothrophin releasing hormone (TRH) study. We describe here a group of patients with minimal signs of hypothyroidism having normal thyroid function tests (T3, T4, thyroid stimulating hormone (TSH)) and have shown exaggerated TSH response to TRH. MATERIAL AND METHODS: Total 82 subjects were studied. Of these, 11 were age and sex matched controls, and 71 were patients. In all subjects TSH and other thyroid assays (T3, T4, FT4) were done by immunoradiometric assay (IRMA), and radioimmunoassay (RIA) respectively. Thyroid antibody was carried out by haemagglutination method. Results were compared to age and sex related normal ranges. To further investigate the status of thyroid axis, TRH study was carried out using standard protocol. RESULTS: Based on TRH study patients were grouped in three categories. Group 1 included 29 patients whose TSH response to TRH was normal. Group 2 included 20 patients with normal baseline TSH and exaggerated TSH response to TRH and Group 3 included 18 patients with baseline TSH in the range of 5 to 10 mu IU/ml and exaggerated TSH response to TRH. There was a significant difference to total T3 between group 1 and 3 (p < 0.05) but mean values were within normal limits. While no significant difference was observed in total T4 between controls and patient's group. Serum TSH values were high in group 3 as compared to controls and Group 1 and 2 (p < 0.0001). For Free T4 no statistical significance was observed between Group 1, 2 and 3. Thyroid antibodies were positive in 22.7% of patients in Group 2 and 33.33% in Group 3. CONCLUSION: We conclude from the present study that even with sensitive TSH assays TRH study still has a role to mark the early stage of hypothyroidism. Those with a normal or upper normal TSH with exaggerated response to TRH are termed as sub-biochemical hypothyroidism and can be considered for thyroid replacement therapy.


Asunto(s)
Adolescente , Adulto , Anciano , Niño , Femenino , Humanos , Hipertiroidismo/sangre , Masculino , Persona de Mediana Edad , Probabilidad , Radioinmunoensayo , Valores de Referencia , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad , Pruebas de Función de la Tiroides , Tirotropina/sangre , Hormona Liberadora de Tirotropina/diagnóstico
2.
Artículo en Inglés | IMSEAR | ID: sea-94293

RESUMEN

Attempt has been made to rationalise the biochemical assessment of patients suspected to have thyroid dysfunction by introduction of a new rapid and supersensitive immunoradiometric assay (IRMA) for TSH. 294 patients were subjected to thyroid investigation viz; tT3, tT4 and TSH (IRMA). Of these, 51 (17.34%) were hypothyroid, 22 (7.48%) were hyperthyroid and 221 (75.1%) were euthyroid. The ratio of thyroid disorder in male to female was 1:3.38. In all patients with hyperthyroidism TSH (IRMA) was 0.05 to undetectable and it was more than 4.5 ulu/ml in hypothyroid patients. TSH (IRMA) was low in one euthyroid patient a 0.34% incidence of false negativity. In 2 patients with subclinical hyperthyroidism TSH (IRMA) was low while tT3 and tT4 were normal. TSH (IRMA) therefore may obviate the need for more time consuming and expensive TRH test and simplify the approach to thyroid function tests in patients suspected to have masked or overt hyperthyroidism.


Asunto(s)
Adolescente , Adulto , Anciano , Niño , Femenino , Humanos , Hipertiroidismo/diagnóstico , Hipotiroidismo/diagnóstico , Ensayo Inmunorradiométrico , Masculino , Persona de Mediana Edad , Pruebas de Función de la Tiroides/métodos , Hormonas Tiroideas/sangre
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA