Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Añadir filtros








Intervalo de año
1.
Chinese Journal of Burns ; (6): 428-433, 2019.
Artículo en Chino | WPRIM | ID: wpr-805468

RESUMEN

Objective@#To observe the therapeutic effects of Archimedes sling system in the rehabilitation of knee joint flexion dysfunction of patients after deep burns.@*Methods@#Thirty-seven patients with knee joint flexion dysfunction after deep burn, conforming to the study criteria and hospitalized in Burn Rehabilitation Center of Tongren Hospital of Wuhan University & Wuhan Third Hospital from March 2015 to December 2017, were recruited in this prospective controlled study. According to the order of admission, 18 odd-numbered patients and 19 even-numbered patients were enrolled in conventional treatment (CT) group [13 males and 5 females, aged (42±10) years] and sling treatment (ST) group [13 males and 6 females, aged (37±10) years] respectively. Patients in group CT were conventionally conducted with knee joint mobilization treatment, continuous passive motion treatment, and pressure therapy, while patients in group ST were conducted with supine knee joint flexion and extension training and micro-squat short arc resistance training with Archimedes sling system besides CT. Patients in the 2 groups were treated for 6 months, and 1 course of treatment was 1 month. Before treatment and after 6 months of treatment, the knee joint active motion range was measured and the difference value was calculated, the American Hospital for Special Surgery (HSS) knee joint score was used to assess the functional disorder of patients, and the self-function satisfaction of patients were evaluated with modified Likert Scale. Data were processed with independent sample t test, paired sample t test, and chi-square test.@*Results@#(1) Before treatment, the difference value of knee joint active motion range of patients in group CT was (45±11)°, which was similar to (44±12)° in group ST (t=-0.206, P>0.05). After 6 months of treatment, the difference value of knee joint active motion range of patients in group ST was (89±14)°, which was obviously higher than (75±12)° in group CT (t=0.897, P<0.01). The difference values of knee joint active motion range of patients in groups CT and ST after 6 months of treatment were obviously higher than those before treatment (t=-13.394, -29.459, P<0.01). (2) Before treatment, the HSS knee joint score of patients in group CT was (40±10) points, which was similar to (36±11) points in group ST (t=0.816, P>0.05). After 6 months of treatment, the HSS knee joint score of patients in group ST was (68±13) points, which was obviously higher than (57±10) points in group CT (t=0.162, P<0.01). The HSS knee joint score of patients in groups CT and ST after 6 months of treatment were obviously higher than those before treatment (t=-12.410, -30.559, P<0.01). (3) Before treatment, the self-function satisfaction scores of patients in the two groups were similar (t=0.140, P>0.05). After 6 months of treatment, the self-function satisfaction score of patients in group ST was obviously higher than that in group CT (t=3.103, P<0.01). The self-function satisfaction scores of patients in groups CT and ST after 6 months of treatment were obviously higher than those before treatment (t=-11.697, -29.029, P<0.01).@*Conclusions@#The Archimedes sling system can effectively increase the difference value of knee joint active motion range, alleviate the degree of knee joint dysfunction, and enhance the self-function satisfaction of patients on the basis of conventional rehabilitation treatment for patients with knee joint flexion dysfunction after deep burns.

2.
Chinese Journal of Burns ; (6): 526-528, 2018.
Artículo en Chino | WPRIM | ID: wpr-807199

RESUMEN

In May 2015, a child with absence of most of the five fingers with scar formation after healing of a left hand burn wound hospitalized in our burn ward. According to the free online design program for making artificial limbs using three-dimensional printing technology on the internet, a utility artificial hand, most of which made of plastic parts, was designed for the child and printed by a three-dimensional printer. The child was instructed to wear and use the utility artificial hand, including driving the finger part of the utility artificial hand to make a grasping action by flexing the wrist joint. On the first day of using the utility artificial hand, the time the right hand and the utility artificial hand took to finish the Nine-Hole Peg Test (NHPT) was 24 and 325 s, respectively. After training, the child could grab some light and rough objects. After 3 months of follow-up, the child could use the utility artificial hand to cooperate with the upper limb of the healthy side to make the movements of picking up the basketball and keeping the balance of body on the bicycle. The time the right hand and the utility artificial hand took to finish NHPT was 21 and 193 s, respectively. The time the utility artificial hand took increased by 40.6% compared with the initial period. By assembling the three-dimensionally printed utility artificial hand, the partial appearance image of the child was restored, and some of the hand functions were compensated, which improved the self-care ability of the child in daily life and was beneficial to his physical and mental development.

3.
Chinese Journal of Burns ; (6): 267-271, 2017.
Artículo en Chino | WPRIM | ID: wpr-808687

RESUMEN

Objective@#To observe the clinical effects of the Joint Active System on the treatment of joint dysfunction after deep burn.@*Methods@#Twenty-two patients with joint dysfunction after deep burn were hospitalized in Institute of Burns of Tongren Hospital of Wuhan University & Wuhan Third Hospital from January 2015 to October 2016, involving 18 elbow joints with flexion disorder, 10 wrist joints with dorsal extension disorder, and 12 ankle joints with dorsal extension disorder. They were treated with the elbow joint activity training device, the wrist joint activity training device, and the ankle joint activity training device of the Joint Active System, respectively. The treatment was carried out 3 times each day with interval of 6 h, 30 minutes each time, and it lasted for four to seven months, with one month as a course of treatment. Before treatment and 1, 2, 3, 4 month (s) after, active motion range of each joint was measured by joint goniometer. Function improvement of each joint was evaluated, and the total effective ratio was calculated 4 months after treatment. Satisfaction degree of patients was assessed by the modified Likert Scale 1, 2, 3, 4 month (s) after treatment. Data were processed with one-way analysis of variance for repeated measurement and LSD test.@*Results@#Before treatment and 1, 2, 3, 4 month (s) after, flexion active motion range of elbow joints were (61±23), (78±22), (89±20), (96±20), and (103±19)°; dorsal extension active motion range of wrist joints were (23±7), (31±6), (38±9), (44±5), and (49±8)°; dorsal extension active motion range of ankle joints were (-31±12), (-23±10), (-16±7), (-12±6), and (-8±4)°, respectively. The active motion range of each joint was obviously higher 1, 2, 3, 4 month (s) after treatment than the previous time point of the same joint (with P values below 0.01). Four months after treatment, the total effective ratios of function improvement of elbow joints, wrist joints, and ankle joints were 5/6, 9/10, and 2/3, respectively. Scores of satisfaction degree of the patients 1, 2, 3, 4 month (s) after treatment were (1.3±0.7), (2.2±1.0), (2.8±0.8), and (3.3±0.6) points, respectively. Scores of satisfaction degree of the patients were obviously higher 2, 3, 4 months after treatment than the previous time point (with P values below 0.05).@*Conclusions@#Joint Active System can improve the active range of motion of each joint obviously in treating joint dysfunction after deep burn, with total effective ratio of function improvement of each joint surpassing 0.66, and the majority of patients are quite satisfied with the curative effects.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA