Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Radiol. bras ; 52(5): 325-330, Sept.-Oct. 2019. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1040966

RESUMEN

Abstract Hepatic lymphoma can be divided into its primary and secondary forms. To be classified as primary hepatic lymphoma, the disease should be limited to the liver and hilar lymph nodes, with no distant involvement (to the bone marrow or other sites). Primary hepatic lymphoma is quite rare, accounting for less than 1% of all cases of non-Hodgkin lymphoma, whereas secondary hepatic lymphoma affects nearly half of such cases. Familiarity with the imaging features of hepatic lymphoma is important for its early diagnosis and appropriate management. In this essay, we aim to review the roles of computed tomography and magnetic resonance imaging in identifying and monitoring hepatic lymphomas, using sample cases to describe and illustrate the wide spectrum of imaging findings in the primary and secondary forms of this disorder.


Resumo O linfoma hepático pode ser dividido em primário e secundário. Para ser classificada como linfoma hepático primário, a doença deve estar limitada ao fígado e linfonodos hilares, sem acometimento de outros órgãos (incluindo a medula óssea). O linfoma hepático primário é muito raro, correspondendo a menos de 1% de todos os linfomas não Hodgkin. Já o envolvimento secundário do fígado ocorre em quase metade dos casos de linfoma não Hodgkin. O conhecimento dos aspectos de imagem do linfoma hepático é importante para o diagnóstico precoce e manejo adequado do paciente. Com base em imagens de casos, nosso objetivo é revisar o papel da imagem por tomografia computadorizada e ressonância magnética na identificação e segmento do linfoma hepático, ilustrando e descrevendo o amplo espectro de achados de imagem observados nas formas primária e secundária da doença.

2.
Clinics ; 69(11): 723-730, 11/2014. tab, graf
Artículo en Inglés | LILACS | ID: lil-731100

RESUMEN

OBJECTIVES: The purpose of our study was to report the results of the implementation of computed tomography colonography in a university hospital setting serving a Brazilian population at high risk of colorectal cancer. METHODS: After creating a computed tomography colonography service in our institution, 85 patients at high risk of colorectal cancer underwent computed tomography colonography followed by a same-day optical colonoscopy from September 2010 to May 2012. The overall accuracy of computed tomography colonography in the detection of lesions ≥6 mm was compared to that of optical colonoscopy (direct comparison). All colonic segments were evaluated using quality imaging (amount of liquid and solid residual feces and luminal distension). To assess patient acceptance and preference, a questionnaire was completed before and after the computed tomography colonography and optical colonoscopy. Fisher's exact test was used to measure the correlations between colonic distension, discomfort during the exam, exam preference and interpretation confidence. RESULTS: Thirteen carcinomas and twenty-two lesions ≥6 mm were characterized. The sensitivity, specificity and accuracy of computed tomography colonography were 100%, 98.2% and 98.6%, respectively. Computed tomography colonography was the preferred method of investigation for 85% of patients. The preparation was reported to cause only mild discomfort for 97.6% of patients. According to the questionnaires, there was no significant relationship between colonic distension and discomfort (p>0.05). Most patients (89%) achieved excellent bowel preparation. There was a statistically significant correlation between the confidence perceived in reading the computed tomography colonography and the quality of the preparation in each colonic segment (p≤0.001). The average effective radiation dose per exam was 7.8 mSv. CONCLUSION: It was possible to institute an efficient computed ...


Asunto(s)
Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Carcinoma/patología , Colonografía Tomográfica Computarizada/métodos , Neoplasias Colorrectales/patología , Brasil , Colectomía/métodos , Colon/patología , Pólipos del Colon/patología , Colonoscopía/métodos , Hospitales Universitarios , Estudios Prospectivos , Reproducibilidad de los Resultados , Medición de Riesgo , Factores de Riesgo , Recto/patología , Sensibilidad y Especificidad
3.
Radiol. bras ; 47(3): 135-140, May-Jun/2014. tab, graf
Artículo en Portugués | LILACS | ID: lil-713631

RESUMEN

Objetivo: Mapear a visão dos cirurgiões sobre o papel da colonografia por tomografia computadorizada (CTC). Materiais e Métodos: Envio de questionário eletrônico aos membros do Colégio Brasileiro de Cirurgiões. O questionário constou de 16 questões de múltipla escolha que abordaram dados demográficos e conhecimentos gerais sobre a CTC. Resultados: Foram obtidas 144 respostas; 90,3% dos especialistas eram homens, 60% com menos de 30 anos de formado, 77,1% eram gastrocirurgiões, 22,9% eram cirurgiões gerais, 53,5% encontravam-se na vida acadêmica e 59,7% exerciam sua atividade profissional em cidades com mais de 500.000 habitantes. Em relação ao conhecimento da CTC, 84,7% conheciam o método, 70,8% sabiam como é realizado, 56,9% relataram conhecer o preparo intestinal utilizado, 31,3% utilizavam o método e 53,5% conheciam algum serviço de CTC na cidade em que atuam. Cerca de metade dos profissionais não conhecia a precisa indicação do método. Profissionais que atuam em cidades com mais de 500.000 habitantes conhecem e utilizam mais o método (p < 0,005). Houve uma tendência de os profissionais com carreira acadêmica utilizarem mais o método. Conclusão: A CTC, embora ainda pouco utilizada em nosso meio, é bastante conhecida, principalmente em grandes centros urbanos e no ambiente acadêmico. .


Objective: To map the view of surgeons on the role played by computed tomography colonography (CTC). Materials and Methods: An electronic questionnaire was sent to members of the Brazilian College of Surgeons. The questionnaire consisted of 16 multiple-choice questions about demographics and general knowledge about CTC. Results: The authors obtained 144 responses; 90.3% of the specialists were men, 60% with less than 30 years from graduation, 77.1% were gastrointestinal surgeons, 22.9% were general surgeons, 53.5% were involved in academic activity, and 59.7% had their professional activity in cities with more than 500,000 inhabitants. As regards the knowledge about CTC, 84.7% of the respondents knew the method, 70.8% knew how it is performed, 56.9% reported knowing the bowel preparation used for the procedure, 31.3% used the method, and 53.5% knew some CTC service in their city. About half of the respondents did not know the precise indication of the method. The method is most frequently known and used by professionals working in cities with more than 500,000 inhabitants (p < 0.005). There was a tendency of a more frequent use of the method by the professionals pursuing an academic career. Conclusion: Despite its infrequent use in Brazil, CTC is a well known method, particularly in large urban centers and in the academic environment. .

4.
Radiol. bras ; 45(3): 139-143, maio-jun. 2012. ilus
Artículo en Portugués | LILACS | ID: lil-640277

RESUMEN

OBJETIVO: O objetivo deste estudo foi avaliar o desempenho de contrastes orais neutros, comparando a capacidade de distensão intestinal, a distinção da parede intestinal, a aceitação e os efeitos colaterais. MATERIAIS E MÉTODOS: Estudo prospectivo, randomizado e duplo-cego em 30 pacientes submetidos a tomografia computadorizada de abdome e pelve com administração de contraste oral neutro, divididos em três grupos: leite, água e polietilenoglicol. Os exames foram analisados quanto ao grau de distensão intestinal e distinção da parede intestinal por dois examinadores em consenso. Os pacientes responderam a um questionário referente ao sabor da solução ingerida e efeitos colaterais. Foram utilizados os testes Kruskal-Wallis e qui-quadrado para as análises estatísticas. RESULTADOS: Distensão intestinal adequada (calibre da alça maior que 2 cm) foi observada em 14 segmentos dos 40 estudados (35%) no grupo leite, em 10 segmentos (25%) no grupo água e em 23 segmentos (57%) no grupo polietilenoglicol (p = 0,01). O preparo com polietilenoglicol resultou na melhor distensão intestinal, porém apresentou o pior sabor e maior incidência de diarreia, referidos pelos pacientes. CONCLUSÃO: O preparo oral com polietilenoglicol promove maior grau de distensão intestinal do que quando se utiliza água ou leite, mas tem pior aceitação, relacionada ao seu sabor e frequência de diarreia.


OBJECTIVE: The purpose of this study was to assess the performance of neutral oral contrast agents, comparing intestinal distention, distinction of intestinal wall, acceptance and side effects. MATERIALS AND METHODS: Prospective, randomized, and double-blinded study involving 30 patients who underwent computed tomography of abdomen and pelvis with administration of neutral oral contrast agents, divided into three groups according the contrast agent type: milk, water, and polyethylene glycol. The images were consensually analyzed by two observers, considering the degree of bowel distention and intestinal wall distinction. The patients responded to a questionnaire regarding the taste of the ingested solution and on their side effects. Kruskal-Wallis and chi-square tests were employed for statistical analysis. RESULTS: Among 40 studied intestinal segments, appropriate bowel distension (intestinal loop diameter > 2 cm) was observed in 14 segments (35%) in the milk group, 10 segments (25%) in the water group and 23 segments (57%) in the polyethylene glycol group (p = 0.01). Preparation with polyethylene glycol resulted in the best bowel distention, but it presented the worst taste and highest incidence of diarrhea as reported by patients. CONCLUSION: Bowel preparation with oral polyethylene glycol results in higher degree of bowel distention than with water or milk, but presents worst acceptance related to its taste and frequency of diarrhea as a side effect.


Asunto(s)
Humanos , Masculino , Femenino , Cetomacrogol/administración & dosificación , Cetomacrogol , Intestino Delgado , Medios de Contraste/administración & dosificación , Medios de Contraste , Agua , Distribución de Chi-Cuadrado , Intestino Delgado/patología , Leche , Estadísticas no Paramétricas , Tomografía Computarizada por Rayos X
5.
Radiol. bras ; 45(3): 160-166, maio-jun. 2012. ilus
Artículo en Portugués | LILACS | ID: lil-640281

RESUMEN

A colonografia por tomografia computadorizada é um método minimamente invasivo para rastreamento de pólipos e do câncer colorretal, com complicações extremamente incomuns, sendo cada vez mais utilizada na prática clínica. Na última década, a evolução no preparo intestinal, na aquisição das imagens e no treinamento dos examinadores determinou um aumento significativo na sensibilidade do método. A interpretação das imagens é realizada por meio da análise combinada das imagens fontes bidimensionais e de diversos tipos de reconstruções tridimensionais, com sensibilidade ao redor de 96% na detecção de lesões com dimensões iguais ou maiores que 10 mm, quando analisadas por radiologistas experientes. Neste ensaio pictórico selecionamos exemplos ilustrativos das doenças e pseudolesões mais frequentemente observadas neste tipo de exame. Apresentamos exemplos de lesões polipoides e planas, benignas e malignas, moléstia diverticular dos cólons, entre outras afecções, bem como pseudolesões, entre as quais aquelas relacionadas a preparo inadequado e interpretação equivocada.


Computed tomography colonography is a minimally invasive method for screening for polyps and colorectal cancer, with extremely unusual complications, increasingly used in the clinical practice. In the last decade, developments in bowel preparation, imaging, and in the training of investigators have determined a significant increase in the method sensitivity. Images interpretation is accomplished through a combined analysis of two-dimensional source images and several types of three-dimensional renderings, with sensitivity around 96% in the detection of lesions with dimensions equal or greater than 10 mm in size, when analyzed by experienced radiologists. The present pictorial essay includes examples of diseases and pseudolesions most frequently observed in this type of imaging study. The authors present examples of flat and polypoid lesions, benign and malignant lesions, diverticular disease of the colon, among other conditions, as well as pseudolesions, including those related to inappropriate bowel preparation and misinterpretation.


Asunto(s)
Humanos , Colon , Pólipos del Colon , Colonografía Tomográfica Computarizada , Neoplasias Colorrectales , Colonoscopía , Medios de Contraste , Endometriosis , Lipoma , Tomografía Computarizada por Rayos X
6.
Radiol. bras ; 45(1): 24-28, jan.-fev. 2012. ilus
Artículo en Portugués | LILACS | ID: lil-618391

RESUMEN

OBJETIVO: Avaliar o grau de aceitação do paciente submetido a colonografia por tomografia computadorizada (CTC) em comparação com a colonoscopia, quando realizadas para rastreamento de doença colorretal. MATERIAIS E MÉTODOS: Cinquenta pacientes com suspeita de doença colorretal foram submetidos a CTC e colonoscopia. Questionários foram aplicados antes e após a realização da CTC e após a colonoscopia. Graduou-se o desconforto esperado e experimentado antes e após a realização da CTC e da colonoscopia, bem como a preferência do paciente por exame. RESULTADOS: Em relação à CTC, antes de iniciar o exame 18 por cento dos pacientes afirmaram esperar pouco desconforto, 78 por cento, desconforto moderado e 4 por cento, muito desconforto. Após a realização do exame, 72 por cento dos pacientes relataram pouco desconforto, 26 por cento, desconforto moderado e apenas um (2 por cento) dos pacientes referiu muito desconforto. Após a realização da colonoscopia, 86 por cento dos pacientes relataram preferência pela CTC. O grau de distensão colônica e a quantidade de fluido residual não influenciaram na preferência dos pacientes. CONCLUSÃO: Os pacientes preferiram a CTC à colonoscopia, não havendo relação estatística com o grau de distensão colônica na CTC e a eficiência do preparo intestinal.


OBJECTIVE: To assess the degree of acceptance of patients undergoing computed tomography colonography (CTC) in comparison with colonoscopy in the screening of colorectal disease. MATERIALS AND METHODS: Fifty patients with suspected colorectal disease underwent CTC and colonoscopy. Questionnaires were administered before and after the performance of the CTC and after the colonoscopy. The discomfort expected and experienced before and after the performance of both procedures as well as the patients' preference for each method were evaluated. RESULTS: As regards CTC, before the procedure, 18 percent of the patients reported expecting little discomfort, 78 percent, mild discomfort, and 4 percent, a lot of discomfort. After the procedure, 72 percent of the patients reported little discomfort, 26 percent, mild discomfort, and only one (2 percent) of the patients reported a lot of discomfort. Upon completion of the colonoscopy, 86 percent of the patients reported their preference for CTC. The degree of colonic distention and residual amount of fluid had no influence on the patients' preference. CONCLUSION: CTC was preferred to colonoscopy, with no statistical relationship with the degree of colonic distention at CTC and efficiency of bowel preparation.


Asunto(s)
Humanos , Neoplasias Colorrectales , Prioridad del Paciente , Satisfacción del Paciente , Colonografía Tomográfica Computarizada , Colonoscopía
7.
Radiol. bras ; 41(6): 355-360, nov.-dez. 2008. ilus, tab
Artículo en Portugués | LILACS | ID: lil-507114

RESUMEN

OBJETIVO: Estabelecer o valor das seqüências ponderadas em T2 para diferenciar cistos simples de hemangiomas hepáticos. MATERIAIS E MÉTODOS: Estudo prospectivo, observacional, transversal e duplo-cego em 52 pacientes com 91 lesões hepáticas (34 cistos simples e 57 hemangiomas) submetidos a ressonância magnética de abdome. A análise conjunta de todas as seqüências realizadas foi considerada o padrão-ouro. Dois observadores independentes avaliaram, subjetivamente, as seqüências TSE com TE longo e B-FFE, procurando diferenciar cistos de hemangiomas. Foram calculadas a eficácia das seqüências e a concordância interobservador e intra-observador por meio do teste kappa (κ) (p < 0,05*). RESULTADOS: As dimensões dos cistos variaram entre 0,5 e 6,5 cm (média de 1,89 cm) e as dos hemangiomas, entre 0,8 e 11 cm (média de 2,62 cm). A concordância entre a avaliação da seqüência com TE longo e o padrão-ouro foi insignificante (κ: 0,00-0,10). A concordância entre a avaliação da seqüência B-FFE e o padrão-ouro variou de substancial (κ: 0,62-0,71) a quase perfeita (κ: 0,86) para ambos os examinadores. A concordância interobservador e intra-observador para a seqüência B-FFE variou entre substancial (κ: 0,62-0,70) e quase perfeita (κ: 0,85-0,91). CONCLUSÃO: A técnica B-FFE apresenta eficácia e reprodutibilidade elevadas na diferenciação de cistos e hemangiomas.


OBJECTIVE: To establish the role of MRI T2-weighted sequences in the differentiation between simple cysts and hepatic hemangiomas. MATERIALS AND METHODS: A double-blinded, prospective, observational, cross-sectional study evaluated 52 patients with 91 hepatic lesions (34 simple cysts and 57 hemangiomas) submitted to abdominal magnetic resonance imaging. The combined analysis of all sequences was considered as the golden-standard. TSE sequences with long echo trains and b-FFE sequences were subjectively analyzed by two independent observers for differentiating cysts from hemangiomas. The kappa test (κ) was utilized in the analysis of the methods accuracy and inter- and intra-observer agreement (p < 0.05*). RESULTS: Cysts and hemangiomas dimensions ranged respectively between 0.5 and 6.5 cm (mean = 1.89 cm), and 0.8 and 11 cm (mean = 2.62 cm). The analysis of the sequences with long-TE and the golden-standard demonstrated a non-statistically significant agreement (κ: 0.00-0.10). The agreement between the evaluation of the b-FFE sequence and the golden-standard ranged from substantial (κ: 0.62-0.71) to almost perfect (κ: 0.86) for both observers. The inter- and intra-observer agreement for the b-FFE sequence ranged from substantial (κ: 0.62-0.70) to almost perfect (κ: 0.85-0.91). CONCLUSION: T2-weighted images acquired with the b-FFE technique present a high accuracy and reproducibility in the differentiation between cysts and hepatic hemangiomas.


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Anciano de 80 o más Años , Quistes/diagnóstico , Quistes/fisiopatología , Hemangioma , Neoplasias Hepáticas , Imagen por Resonancia Magnética , Estudios Prospectivos , Sensibilidad y Especificidad
8.
Radiol. bras ; 41(2): 119-127, mar.-abr. 2008. ilus
Artículo en Portugués | LILACS | ID: lil-482999

RESUMEN

Uma grande variedade de tumores benignos e malignos ocorre no fígado. Embora a caracterização de lesões hepáticas focais possa ser um desafio para o radiologista, a maioria das lesões se apresenta com características de imagem que permitem o seu diagnóstico. O objetivo deste trabalho é o de rever os principais aspectos de imagem dos tumores hepáticos benignos e malignos mais comumente encontrados no fígado adulto.


A wide range of both benign and malignant neoplasms may occur in the liver. Although the characterization of focal hepatic lesions may represent a diagnostic challenge for radiologists, typical imaging findings in these lesions allow a correct diagnosis. The present study is aimed at reviewing imaging findings both in the most frequent benign and malignant focal lesion found in the adult liver.


Asunto(s)
Adenoma , Diagnóstico por Imagen , Hiperplasia Nodular Focal , Hígado/fisiopatología , Neoplasias Hepáticas , Neoplasias Hepáticas/diagnóstico , Hepatopatías/etiología , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X
9.
São Paulo med. j ; 125(2): 102-107, Mar. 2007. graf, tab, ilus
Artículo en Inglés | LILACS | ID: lil-454752

RESUMEN

CONTEXT AND OBJECTIVE: Recent studies have shown noncontrast computed tomography (NCT) to be more effective than ultrasound (US) for imaging acute ureterolithiasis. However, to our knowledge, there are few studies directly comparing these techniques in an emergency teaching hospital setting. The objectives of this study were to compare the diagnostic accuracy of US and NCT performed by senior radiology residents for diagnosing acute ureterolithiasis; and to assess interobserver agreement on tomography interpretations by residents and experienced abdominal radiologists. DESIGN AND SETTING: Prospective study of 52 consecutive patients, who underwent both US and NCT within an interval of eight hours, at Hospital São Paulo. METHODS: US scans were performed by senior residents and read by experienced radiologists. NCT scan images were read by senior residents, and subsequently by three abdominal radiologists. The interobserver variability was assessed using the kappa statistic. RESULTS: Ureteral calculi were found in 40 out of 52 patients (77 percent). US presented sensitivity of 22 percent and specificity of 100 percent. When collecting system dilatation was associated, US demonstrated 73 percent sensitivity, 82 percent specificity. The interobserver agreement in NCT analysis was very high with regard to identification of calculi, collecting system dilatation and stranding of perinephric fat. CONCLUSIONS: US has limited value for identifying ureteral calculi in comparison with NCT, even when collecting system dilatation is present. Residents and abdominal radiologists demonstrated excellent agreement rates for ureteral calculi, identification of collecting system dilatation and stranding of perinephric fat on NCT.


CONTEXTO E OBJETIVO: Estudos atuais demonstram que a tomografia computadorizada helicoidal sem contraste (TC) apresenta maior acurácia do que a ultra-sonografia (US) no diagnóstico da ureterolitíase aguda, porém, poucos estudos a esse respeito foram realizados em atendimento radiológico de urgência de hospital universitário. Nossos objetivos foram comparar a sensibilidade diagnóstica da US com a TC realizadas por residentes no diagnóstico de ureterolitíase aguda e comparar a análise da TC interpretada por residentes e radiologistas experientes. TIPO DE ESTUDO E LOCAL: Estudo prospectivo de 52 pacientes com cólica renal aguda, que foram submetidos a exame de US seguido de TC em período máximo de oito horas no Hospital São Paulo. MÉTODOS: Os exames de US foram realizados por médicos residentes e conferidos pelos preceptores, já os de TC foram analisados por outro residente e posteriormente analisados por três radiologistas independentes. RESULTADOS: Nos 52 pacientes analisados foram encontrados 40 cálculos ureterais na TC (77 por cento). A US apresentou uma sensibilidade de 22 por cento e especificidade de 100 por cento, que aumentou para 73 por cento e 82 por cento respectivamente, quando se associou a identificação da dilatação do sistema coletor. A TC analisada pelo residente e pelos radiologistas apresentou uma excelente correlação para identificação do cálculo ureteral, para heterogeneidade da gordura peri-renal e para dilatação do sistema coletor. CONCLUSÕES: A US realizada pelos residentes tem menor sensibilidade no diagnóstico da litíase ureteral, quando comparada à TC, mesmo quando associada à presença de dilatação do sistema coletor. Residentes e radiologistas especialistas apresentaram excelente concordância no diagnóstico de litíase ureteral.


Asunto(s)
Humanos , Variaciones Dependientes del Observador , Tomografía Computarizada Espiral/normas , Cálculos Ureterales , Cálculos Ureterales , Enfermedad Aguda , Métodos Epidemiológicos , Hospitales de Enseñanza , Internado y Residencia , Médicos , Competencia Profesional , Radiografía Abdominal , Radiología
10.
Radiol. bras ; 39(5): 341-344, set.-out. 2006. ilus, tab
Artículo en Portugués | LILACS | ID: lil-446726

RESUMEN

OBJETIVO: Avaliar a reprodutibilidade da tomografia computadorizada sem contraste na avaliação da litíase ureteral e os sinais secundários de obstrução do sistema coletor em pacientes com cólica renal aguda. MATERIAIS E MÉTODOS: Estudo prospectivo de 52 pacientes com diagnóstico clínico de cólica renal aguda submetidos a exame de tomografia computadorizada de abdome sem contraste. Os exames foram realizados com técnica helicoidal e posteriormente analisados por três observadores independentes, com a concordância interobservador avaliada pelo método estatístico kappa (kapa). Foram analisados os parâmetros: a) presença, localização e mensuração dos cálculos ureterais; b) dilatação do sistema coletor intra-renal; c) heterogeneidade da gordura perirrenal; d) dilatação ureteral; e) edema da parede ureteral (sinal do halo). RESULTADOS: Foram encontrados 40 cálculos ureterais na tomografia computadorizada (77 por cento). A concordância interobservador para a identificação do cálculo ureteral e da dilatação ureteral foi quase perfeita (kapa = 0,89 e kapa = 0,87, respectivamente), substancial para dilatação do sistema coletor intra-renal (kapa = 0,77) e moderada para heterogeneidade da gordura perirrenal e para edema da parede ureteral (kapa = 0,55 e kapa = 0,56, respectivamente). CONCLUSÃO: A tomografia computadorizada de abdome sem contraste apresenta elevada reprodutibilidade na avaliação da litíase ureteral e dos sinais secundários de obstrução do sistema coletor.


OBJECTIVE: To evaluate the interobserver agreement on non-contrast computed tomography interpretation by a group of experienced abdominal radiologists, for the study of urolithiasis in patients presenting acute flank pain. MATERIALS AND METHODS: Prospective study of 52 patients submitted to non-contrast enhanced helical computed tomography. The images were subsequently analyzed by three independent observers, with the interobserver agreement assessed by means of the kappa (kappa) statistical method. The following parameters were analyzed: a) presence, localization and measurement of ureteral calculi; b) intrarenal calyceal system dilatation; c) perirenal fat heterogeneity; d) ureteral dilatation; e) ureteral wall edema (halo sign). RESULTS: Ureteral calculi were found in 40 of 52 patients (77 percent). The interobserver agreement was almost perfect as regards identification of ureteral calculi (kappa = 0.89) and ureteral dilatation (kappa = 0.87), substantial for calyceal system dilatation (kappa = 0.77), and moderate for perirenal fat heterogeneity (kappa = 0.55) and ureteral wall edema (kappa = 0.56). CONCLUSION: Non-contrast-enhanced abdominal computed tomography presents high reproducibility in the evaluation of urolithiasis and secondary signs of the calyceal system obstruction.


Asunto(s)
Humanos , Masculino , Femenino , Adolescente , Adulto , Persona de Mediana Edad , Cálculos Ureterales/complicaciones , Dolor en el Flanco/etiología , Litiasis/diagnóstico , Cálculos Ureterales , Radiografía Abdominal , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X
11.
Radiol. bras ; 36(5): 305-309, set.-out. 2003. ilus, tab
Artículo en Portugués | LILACS | ID: lil-351428

RESUMEN

A ressonância magnética é uma técnica de grande importância na avaliação do fígado. Assim como na tomografia computadorizada helicoidal, o emprego de aquisições rápidas, em fases diferentes da vascularização hepática, auxilia na detecção e caracterização de tumores. Contudo, algumas armadilhas podem confundir e dificultar a interpretação do exame, simulando lesões parenquimatosas. Estas armadilhas têm forma, localização e características variadas, sendo denominadas de pseudolesões. Podem ser decorrentes de diversos fatores, como alterações perfusionais, esteatose focal, parênquima hepático preservado na esteatose difusa, artefatos, entre outros. É muito importante que sejam reconhecidas, para que não sejam causas de resultados falso-positivos. O objetivo deste ensaio é classificar e ilustrar as diversas pseudolesões hepáticas na ressonância magnética, com breve descrição delas, e alternativas para diferenciá-las das lesões do parênquima.


Magnetic resonance imaging is currently an important method for the assessment of the liver. As with helical computed tomography, the use of fast magnetic resonance imaging sequences to obtain data from the different phases of vascularization allows the detection and identification of tumors. However, some lesions may mimic true parenchymatous lesions which are interpretation pitfalls. These lesions are called pseudolesions and may occur due to perfusion defects, focal fatty infiltration, and spared areas of fatty liver or artifacts, among other causes. The recognition of these lesions is essential to avoid false-positive results. The aim of this study was to classify, illustrate, and briefly describe these pseudolesions, and to provide alternatives to differentiate pseudolesions from true parenchymatous lesions


Asunto(s)
Errores Diagnósticos , Diagnóstico por Imagen , Hígado/lesiones , Hígado/patología , Imagen por Resonancia Magnética , Sensibilidad y Especificidad
12.
Radiol. bras ; 36(1): 9-10, jan.-fev. 2003. ilus, tab, graf
Artículo en Portugués | LILACS | ID: lil-331817

RESUMEN

OBJETIVO: Estudar as características morfológicas e quantitativas dos hemangiomas hepáticos na ressonância magnética. MATERIAL E MÉTODOS: Foram estudados, prospectivamente, 57 hemangiomas hepáticos presentes em 27 pacientes, com ressonância magnética de alto campo (1,5 T) utilizando seqüência spin-eco, imagens ponderadas em T1 e T2, com tempos de eco de até 160 ms. Foram avaliadas as características morfológicas dos hemangiomas, classificando-os em típicos ou atípicos. Também foram avaliadas características quantitativas das lesões (relação intensidade de sinal lesão/fígado, valores de tempo de relaxação T2 e índice simplificado T2) e feitas comparações entre tais características nos hemangiomas morfologicamente típicos e atípicos, e naqueles com dimensões £ 2,0 cm e > 2,0 cm. RESULTADOS: Do total de hemangiomas estudados, 78,9 por cento apresentaram características morfológicas típicas. Não houve diferença significante entre as características quantitativas de hemangiomas morfologicamente típicos e atípicos. Hemangiomas com dimensões £ 2,0 cm e > 2,0 cm apresentaram comportamento semelhante em relação ao tempo de relaxação T2 e ao índice simplificado T2. Valores da relação intensidade de sinal lesão/fígado apresentaram diferenças significantes entre esses dois grupos. Os valores do tempo de relaxação T2, do índice simplificado T2 e da relação intensidade de sinal lesão/fígado caracterizaram corretamente 96,5 por cento, 93 por cento e 89,5 por cento de todos os hemangiomas, respectivamente. CONCLUSÃO: A avaliação quantitativa dos hemangiomas hepáticos nas imagens por ressonância magnética é um método simples e, conjuntamente com a análise morfológica, propicia maior confiança para o diagnóstico


OBJECTIVE: To evaluate the qualitative (morphological) and quantitative characteristics of hepatic hemangiomas with magnetic resonance imaging. MATERIAL AND METHODS: Twenty-seven patients with 57 hemangiomas were prospectively studied with magnetic resonance imaging using a system operating at 1.5 T. T1- and T2-weighted spin-echo images were obtained, including heavily T2-weighted images with TE of 160 ms. The morphological characteristics of the hemangiomas were studied and the lesions were classified as typical or atypical. Quantitative parameters (T2 relaxation time, simplified T2 index and lesion/liver signal intensity ratio) were also calculated. The values obtained for typical and atypical hemangiomas were compared as well as for the hemangiomas measuring £ 2.0 cm and > 2.0 cm. RESULTS: 78.9% of hemangiomas showed typical morphological features. There was no difference between the quantitative values for typical and atypical hemangiomas. There was not significant difference in T2 relaxation times and values of simplified T2 index in hemangiomas measuring £ 2.0 cm and > 2.0 cm. Lesion/liver signal intensity ratios showed significant differences between the two groups. T2 relaxation times, the simplified T2 index and the lesion/liver signal intensity ratios correctly characterized 96.5%, 93%, and 89.5% of the hemangiomas, respectively. CONCLUSION: Quantitative analysis of hepatic hemangiomas is a simple technique that in conjunction with morphological evaluation provides a more reliable characterization of these tumors.


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Hígado/patología , Hemangioma , Hemangioma/patología , Hemangioma , Diagnóstico por Imagen , Hígado/fisiopatología , Imagen por Resonancia Magnética , Estudios Prospectivos , Estudios de Evaluación como Asunto , Tomografía Computarizada por Rayos X
13.
Radiol. bras ; 35(6): 329-334, nov.-dez. 2002. ilus
Artículo en Portugués | LILACS | ID: lil-331006

RESUMEN

Desde o início da década de 80 a ressonância magnética vem sendo utilizada para o estudo do abdome e principalmente na detecção de nódulos hepáticos. As imagens ponderadas em T2 são as que trouxeram maior benefício quando comparadas à tomografia computadorizada com contraste. Inúmeras técnicas e seqüências de ressonância magnética ponderadas em T2 surgiram desde então, na tentativa de aumentar a eficácia diagnóstica, com menores tempos de exame. Neste sentido, foram publicados inúmeros trabalhos demonstrando a utilidade de seqüências rápidas e ultra-rápidas, com e sem supressão de gordura, em apnéia, com sincronizador respiratório e com bobinas de sinergia, entre outros avanços tecnológicos. No entanto, não há um consenso sobre qual a técnica mais apropriada e sensível para a detecção de lesões hepáticas focais. Neste artigo fazemos uma revisão bibliográfica e análise crítica das diversas técnicas de imagens ponderadas em T2, no que diz respeito às suas sensibilidades na detecção de nódulos hepáticos


Since the early 1980's several magnetic resonance imaging pulse sequences have been developed in order to determine the optimum imaging technique for the detection and characterization of hepatic lesions. T2-weighted images play an important role in the evaluation of the liver and present equal or greater sensitivity than enhanced computed tomography for the detection of liver lesions. New techniques for obtaining T-2 weighted images have been developed in the attempt to optimize the method. These techniques have improved the image quality by shortening examination time, reducing motion artifacts, and improving contrast-to-noise ratio. The effectiveness of the different techniques (fat suppression, breath-hold, respiratory-triggered and phased-array coils) has been tested in many comparative studies, although the results are controversial. In this article we review the literature and discuss the several T2-weighted image techniques, particularly with regard to sensitivity to detect focal liver lesions.


Asunto(s)
Humanos , Abdomen/patología , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/fisiopatología , Técnicas de Diagnóstico del Sistema Digestivo , Diagnóstico por Imagen de Elasticidad , Espectroscopía de Resonancia Magnética , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X
15.
Radiol. bras ; 31(1): 49-52, jan.-fev. 1998. ilus, tab
Artículo en Portugués | LILACS | ID: lil-213076

RESUMEN

A prevalência de divertículos do intestino delgado, em autópsias, varia de 0,26 por cento a 1,3 por cento, embora possam ser encontrados em até 2,3 por cento dos pacientes, por meio de estudos radiológicos. Os pacientes säo assintomáticos em cerca de 90 por cento dos casos. No entanto, podem apresentar sintomas inespecíficos ou desenvolver complicaçöes que requeiram tratamento, como diverticulite. Outras complicaçöes incluem síndrome de mal absorçäo, obstruçäo e hemorragias intestinais, entre outras. Os autores apresentam dois casos de diverticulose do intestino delgado que evoluíram com sintomas de obstruçäo intestinal. Um paciente apresentou aderências peritoniais (bridas), desenvolvidas provavelmente após diverticulite prévia. O outro paciente apresentou quadro de suboclusäo intestinal, tratada clinicamente. Säo discutidos a patogênese


Asunto(s)
Humanos , Persona de Mediana Edad , Masculino , Femenino , Divertículo/fisiopatología , Intestino Delgado/lesiones
16.
São Paulo; s.n; 1998. 132 p. ilus, tab.
Tesis en Portugués | LILACS | ID: lil-272268

RESUMEN

Realizamos estudo prospectivo e analisamos as características morfológicas e quantitativas (valores de tempo de relaxaçao T2, índice T2, e relaçao intensidade de sinal lesao / fígado [RLF]) de 57 hemangiomas hepáticos (presentes em 27 pacientes) em ressonância magnética (RM) de 1,5T. Utilizamos a seqüência spin-eco (SE), com imagens ponderadas em Tl e T2, nestas últimas usando também tempos de eco (TE) longos, de até 160 mseg.. Os nossos objetivos foram estabelecer a freqüência de hemangiomas hepáticos com características morfológicas típicas e atípicas na RM, avaliar a concordância entre examinadores na classificaçao morfológica dos hemangiomas, e verificar se há diferença entre o comportamento quantitativo de hemangiomas morfologicamente típicos e atípicos, e de dimensoes < 2,0 cm e > 2,0 cm. Os resultados mostraram que 78,9 por cento dos hemangiomas apresentaram características morfológicas típicas, e que houve concordância entre os examinadores na classificaçao morfológica dos hemangiomas em típicos e atípicos. Valores do tempo de relaxaçao T2, do índice T2 e da RLF caracterizaram corretamente 96,5 por cento ; 93 por cento ; e 89,5 por cento dos hemangiomas, respectivamente. Nao houve diferença significante entre o comportamento quantitativo de hemangiomas morfologicamente típicos e atípicos. Hemangiomas com dimensoes < 2,0 cm e > 2,0 cm apresentaram comportamento semelhante em relaçao ao tempo de relaxaçao T2 e ao índice simplificado T2. Valores da RLF apresentaram diferenças sígnificantes entre estes dois grupos. Os parâmetros quantitativos permitem a caracterizaçao da grande maioria dos hemangiomas hepáticos morfologicamente típicos e atípicos, e daqueles com dimensoes < 2,0 cm e > 2,0 cm, aumentando, desta maneira, o nível de confiança da RM no diagnóstico destas lesoes


Asunto(s)
Hemangioma , Neoplasias Hepáticas , Imagen por Resonancia Magnética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA