Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Artículo en Inglés | IMSEAR | ID: sea-42839

RESUMEN

OBJECTIVE: To describe the experience of transabdominal chorionic villus sampling (CVS) at Maharaj Nakorn Chiang Mai Hospital. MATERIAL AND METHOD: Between January 2004 and July 2006, 185 pregnant women chose to have CVS for prenatal diagnosis after counseling. Transabdominal CVS under ultrasound guidance was performed in all cases under local anesthesia using spinal needle 20-gauge with back and forth movement technique. The sample was immediately examined under a microscope to determine if the villi were obtained and to remove the decidua (maternal cells) from the villi. RESULTS: The mean gestational age was 12.25 +/- 1.05 weeks (range 10-20 weeks). The procedure was successful in all cases, 168 cases (90.9%) with one attempt. The indications for prenatal diagnosis included fetal risk for chromosomal abnormalities (110 cases; 59.46%), severe thalassemia syndrome (57 cases; 30.81%), both of them (17 cases; 9.19%) and for HLA typing in one case. The results could not be obtained in 11 cases (5.95%) due to laboratory failure. In the present study, abnormal chromosomes were detected in chorionic villi from 12 fetuses, including 45,X (3), trisomy 18 (3), trisomy 21 (2), trisomy 7 (1) and mosaicism (3). Additionally, 18 fetuses with severe thalassemia syndrome were identified; five homozygous beta-thalassemia, 11 beta-thalassemia/Hb E disease, and two homozygous alpha-thalassemia (Hb Bart's). The complications found in the present study included one case (0.54%) of fetal loss following the procedure and one case (0.54%) of vaginal bleeding. No case with limb reduction defect, infection, or rupture of membranes following the procedure was seen. CONCLUSIONS: Transabdominal CVS is a rather safe and reliable prenatal diagnostic technique. The fetal loss rate following the procedure in the present study was 0.54%. However operator' experience and skill in ultrasound-directed needle guidance procedure are essential.


Asunto(s)
Abdomen , Adulto , Anciano , Muestra de la Vellosidad Coriónica , Femenino , Mortalidad Fetal , Edad Gestacional , Prueba de Histocompatibilidad , Humanos , Masculino , Persona de Mediana Edad , Atención Prenatal , Diagnóstico Prenatal/métodos , Evaluación de Programas y Proyectos de Salud , Estudios Retrospectivos , Tailandia
2.
Artículo en Inglés | IMSEAR | ID: sea-45695

RESUMEN

OBJECTIVE: To describe the experience of the first 50 cases of cordocentesis after practicing with cordocentesis model. MATERIAL AND METHOD: Cordocentesis model consisted of a water-filled transparent glass box covered with a rubber latex sheet with or without piece of pork skin. A 30-cm umbilical cord filled with mercurochrome, hung inside the container, was the target for the puncture. As in real practice, the trainee had to try to aspirate the red mercurochrome from the umbilical cord using a spinal needle under ultrasonographic guidance. After practicing with the model for 300 procedures, the trainee was allowed to perform cordocentesis on pregnant women at gestational age of 18-22 weeks by herself under expert supervision with time limit of 30 minutes. The procedure not successful in 30 minutes was considered failure. Duration of procedures, placental site, puncture site, and related complications were recorded for subsequent analysis. RESULTS: After practicing with model for 300 procedures, real cordocentesis was performed by the trainee on 50 pregnant women. The success rate in obtaining fetal blood within 30 minutes was 100%. Most of them (92%) took less than 10 minutes to complete the procedure. Puncture site bleeding and fetal bradycardia were the most common immediate complications, found in 30% and 8% respectively, and spontaneously resolved within few minutes. CONCLUSION: Without any fetal and maternal jeopardy, cordocentesis model is simple, inexpensive but highly effective for the beginner to gain their experience, skill and prepare themselves for cordocentesis with confidence. However, the reduction of fetal loss rate with the training program remains to be further tested.


Asunto(s)
Cordocentesis/métodos , Educación Médica/métodos , Femenino , Humanos , Maniquíes , Modelos Educacionales , Simulación de Paciente , Embarazo , Enseñanza/métodos
3.
Artículo en Inglés | IMSEAR | ID: sea-41605

RESUMEN

The objective of this report was to demonstrate prenatal sonographic features of congenital ductus arteriosus aneurysm (DAA), a rare, but possibly fatal abnormality. It is characterized by a saccular or fusiform dilatation of the ductus arteriosus. The majority of affected neonates are clinically asymptomatic and tend to progressively diminish in size of DAA and spontaneous closure. However, serious complications can occur during waiting periods, including spontaneous rupture or thromboembolism. Case: A 35 year-old Thai woman, G2P1, underwent ultrasound examination at 34 weeks' gestation. Fetal echocardiography revealed markedly enlarged and tortuous ductus arteriosus with saccular dilation at the distal end, just before joining the descending aorta. The cross-sectional diameter of the saccular portion of the ductus arteriosus was 10 mm. The active female baby was vaginally delivered at 34 weeks' gestation, weighing 1050 grams. Postnatal echocardiography confirmed the prenatal findings. The DAA was gradually decreased in size and finally spontaneously closed without medical or surgical intervention.


Asunto(s)
Adulto , Aneurisma/congénito , Anomalías Cardiovasculares/diagnóstico por imagen , Conducto Arterial/anomalías , Ecocardiografía , Femenino , Humanos , Embarazo , Tercer Trimestre del Embarazo , Ultrasonografía Prenatal
4.
Artículo en Inglés | IMSEAR | ID: sea-43308

RESUMEN

OBJECTIVE: To evaluate the incidence and volume of feto-maternal hemorrhage following cordocentesis. STUDY DESIGN: Descriptive study. MATERIAL AND METHOD: One hundred and sixteen asymptomatic non-anemic pregnant women with an indication for cordocentesis at 18-22 weeks of gestation between January and June 2004 were recruited. Maternal blood samples were obtained immediately before and 30 minutes after cordocentesis. Fetal cells in the maternal blood were counted using Kleihauer Betke test. About 25,000 maternal cells per slide were scanned by the same examiner. Feto-maternal hemorrhage was considered significant if the fetal bleeding was more than 0.25 ml. RESULTS: There was a significant increase in fetal blood volume in maternal circulation after cordocentesis (Paired Students t test, p < 0.001). A significant hemorrhage (> 0.25 ml) occurred in 63 from 116 women (54. 7%). Only one had marked hemorrhage of more than 5.0 ml and none had massive hemorrhage (> 15 ml). CONCLUSION: Cordocentesis at 18-22 weeks of gestation can be associated with feto-maternal hemorrhage in more than half of the cases but nearly all cases had only minimal hemorrhage and none had massive hemorrhage.


Asunto(s)
Adolescente , Adulto , Cordocentesis/efectos adversos , Femenino , Transfusión Fetomaterna/epidemiología , Humanos , Incidencia , Persona de Mediana Edad , Embarazo , Segundo Trimestre del Embarazo , Tailandia/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA