Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Añadir filtros








Intervalo de año
1.
Chonnam Medical Journal ; : 112-114, 2014.
Artículo en Inglés | WPRIM | ID: wpr-75446

RESUMEN

Percutaneous coronary intervention (PCI) of stumpless chronic total occlusion (CTO) lesions with a side branch stemming from the occlusion have a significantly lower treatment success rate because physicians cannot identify an accurate entry point with only conventional angiographic images. An intravascular ultrasonography (IVUS)-guided wiring technique might be useful for the penetration of stumpless CTO. We recently experienced thrombotic occlusion during an IVUS-guided stumpless CTO procedure. The cause of the thrombosis is not completely understood; the thrombosis may have been associated with the long use of the IVUS catheter. Special precautions should be taken to prevent thrombus in such cases.


Asunto(s)
Catéteres , Intervención Coronaria Percutánea , Trombosis , Ultrasonografía Intervencional
2.
Chonnam Medical Journal ; : 112-114, 2014.
Artículo en Inglés | WPRIM | ID: wpr-788293

RESUMEN

Percutaneous coronary intervention (PCI) of stumpless chronic total occlusion (CTO) lesions with a side branch stemming from the occlusion have a significantly lower treatment success rate because physicians cannot identify an accurate entry point with only conventional angiographic images. An intravascular ultrasonography (IVUS)-guided wiring technique might be useful for the penetration of stumpless CTO. We recently experienced thrombotic occlusion during an IVUS-guided stumpless CTO procedure. The cause of the thrombosis is not completely understood; the thrombosis may have been associated with the long use of the IVUS catheter. Special precautions should be taken to prevent thrombus in such cases.


Asunto(s)
Catéteres , Intervención Coronaria Percutánea , Trombosis , Ultrasonografía Intervencional
3.
Chonnam Medical Journal ; : 23-26, 2014.
Artículo en Inglés | WPRIM | ID: wpr-788280

RESUMEN

Generally, early exercise after coronary stenting is considered safe, but isolated cases of acute stent thrombosis have been associated with the performance of a treadmill exercise test after percutaneous coronary intervention (PCI). The treadmill exercise test is often used to noninvasively assess the functional result of PCI. In this report, we describe a case of terrible stent thrombosis related to an exercise test performed 3 days after stenting, and the patient died as the result of an intractable thrombus.


Asunto(s)
Humanos , Prueba de Esfuerzo , Intervención Coronaria Percutánea , Stents , Trombosis
4.
Chonnam Medical Journal ; : 23-26, 2014.
Artículo en Inglés | WPRIM | ID: wpr-111163

RESUMEN

Generally, early exercise after coronary stenting is considered safe, but isolated cases of acute stent thrombosis have been associated with the performance of a treadmill exercise test after percutaneous coronary intervention (PCI). The treadmill exercise test is often used to noninvasively assess the functional result of PCI. In this report, we describe a case of terrible stent thrombosis related to an exercise test performed 3 days after stenting, and the patient died as the result of an intractable thrombus.


Asunto(s)
Humanos , Prueba de Esfuerzo , Intervención Coronaria Percutánea , Stents , Trombosis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA