RESUMEN

ABSTRACT A 51-year-old patient underwent posterior vitrectomy with perfluoropropane gas injection, phacoemulsification, and implantation of an Oft Cryl® hydrophilic acrylic intraocular lens (IOL) because of traumatic retinal detachment and cataract in the right eye. On the first postoperative day, gas was filling the anterior chamber because of patient's non-compliance in terms of head positioning, and was reabsorbed within one week. Eight months later, the patient returned complaining of a significant decrease in vision. IOL opacification was noticed by slit-lamp examination. The lens was explanted to undergo gross and light microscopic analysis. The lens was also stained with the alizarin red method for calcium identification. Light microscopic analysis confirmed the presence of granular deposits, densely distributed in an overall circular pattern in the central part of the lens optic. The granules stained positive for calcium. This is the first case of the opacification of this type of hydrophilic lens. Surgeons should be aware of this potential postoperative complication, and the use of hydrophilic IOLs should be avoided in procedures involving intracameral gas because of the risk of IOL opacification.


RESUMO Uma paciente de 51 anos foi submetida à vitrectomia posterior com injeção de gás perfluoropropano, facoemulsificação e implante de lente intraocular (LIO) acrílica hidrofílica Oft cryl® devido a descolamento traumático da retina e catarata. No primeiro dia pós-operatório, o gás estava ocupando a câmara anterior pois a paciente não manteve o decúbito ventral restrito, tendo sido absorvido ao longo de uma semana. Oito meses depois, a paciente retornou com baixa da acuidade visual. Ao exame foi evidenciado opacificação da lente intraocular. A lente foi explantada e submetida à análise macroscópica e sob microscopia óptica. Também, foi corada pelo método de vermelho de alizarina, que identifica cálcio. A análise sob microscopia óptica evidenciou depósitos granulares, densamente distribuídos em padrão circular na parte central da óptica da lente intraocular, que coraram positivo para cálcio. Esse é o primeiro relato de opacificação dessa lente hidrofílica. Os cirurgiões devem estar atentos para esta potencial complicação pós-operatória.


Asunto(s)
Humanos , Femenino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Falla de Prótesis/etiología , Implantación de Lentes Intraoculares/efectos adversos , Lentes Intraoculares/efectos adversos , Vitrectomía , Facoemulsificación , Remoción de Dispositivos , Fluorocarburos , Microscopía/métodos
2.
Arq. bras. oftalmol ; 77(4): 222-224, Jul-Aug/2014. graf
Artículo en Inglés | LILACS | ID: lil-728663

RESUMEN

Purpose: To evaluate the incidence of posterior capsule opacification (PCO) four years after the implantation of a hydrophilic acrylic intraocular lens (IOL). Methods: Fifty-eight randomly selected eyes from 58 patients were analyzed four years after phacoemulsification and Ioflex IOL implantation. The patients underwent an ophthalmic examination to detect PCO and a detailed medical history was obtained. The patients' charts were reviewed for their corrected distance visual acuity prior to the IOL implantation, as well as for one month postoperatively. The Student's t-test was used for statistical analysis. Results: The mean age of patients without PCO was 74.6 ± 9.5 years, compared to 70.3 ± 15 years in patients with PCO. Four years after surgery, 39 of the 58 eyes (67%) had detectable PCO and 24 eyes (41.3%) had decreased visual acuity (VA) due to PCO. These patients were referred for Nd:YAG laser capsulotomy. Three patients (5.1%) had decreased VA due to glaucoma, IOL opacification, or age-related macular degeneration. Twelve eyes (20.7%) presented mild PCO with unchanged VA. Systemic arterial hypertension was reported by 45% of the patients, and in 3.5% of these cases this was associated with diabetes mellitus. Conclusion: This study found the incidence of PCO to be 67% four years after phacoemulsification and Ioflex IOL implantation. .


Objetivo: Avaliar a incidência da opacificação da cápsula posterior com o implante de uma lente intraocular acrílica hidrofílica. Métodos: Cinquenta e oito olhos, de 58 pacientes, selecionados de forma aleatória, foram examinados 4 anos após a cirurgia de facoemulsificação com implante da lente intraocular Ioflex em uma campanha comunitária para pessoas carentes. Os pacientes foram submetidos ao exame oftalmológico a fim de detectar opacificação da cápsula posterior. Foi obtido histórico médico detalhado. A acuidade visual corrigida antes e 1 mês após a cirurgia foi obtida através de revisão em prontuário médico. O teste t de student foi utilizado para a análise estatística. Resultados: A idade média dos pacientes sem opacificação da cápsula posterior foi 74,6 ± 9,5 anos, e 70,3 ± 15 anos nos pacientes com opacificação da cápsula posterior. Após 4 anos da cirurgia, 39 olhos (67%) foram diagnosticados com opacificação da cápsula posterior, e 24 olhos (41,3%) tiveram redução da acuidade visual causada pela opacificação da cápsula posterior, sendo encaminhados para realização de capsulotomia com Nd:YAG laser. Três olhos (5,1%) tiveram redução da acuidade visual causada por glaucoma, opacificação da lente intraocular e degeneração macular relacionada á idade. Em outros 12 olhos (20,7%) que apresentaram opacificação da cápsula posterior, a acuidade visual ficou mantida. Dentre as doenças sistêmicas, a hipertensão arterial foi relatada por 45% da amostra avaliada e 3,5% referiram diabetes mellitus. Conclusão: O estudo encontrou incidência de 67% de opacificação da cápsula posterior na lente intraocular Ioflex 4 anos ...


Asunto(s)
Anciano , Femenino , Humanos , Masculino , Resinas Acrílicas/efectos adversos , Opacificación Capsular/etiología , Extracción de Catarata/efectos adversos , Implantación de Lentes Intraoculares/efectos adversos , Opacificación Capsular/epidemiología , Estudios de Seguimiento , Incidencia , Complicaciones Posoperatorias , Agudeza Visual
3.
Rev. bras. oftalmol ; 71(3): 173-179, maio-jun. 2012. graf, tab
Artículo en Portugués | LILACS | ID: lil-643915

RESUMEN

OBJETIVO: Analisar a percepção dos pós-graduandos participantes quanto à qualidade dos cursos lato sensu de oftalmologia do Brasil e apontar as áreas que necessitam melhorias. MÉTODOS: Realizou-se um estudo transversal e descritivo com 107 pós-graduandos de oftalmologia de cursos credenciados pelo Ministério da Educação e Cultura (MEC) e/ou Conselho Brasileiro de Oftalmologia (CBO).Avaliou-se através de questionário as preceptorias (clínica, cirúrgica e emergência), as necessidades de melhoria curricular, aulas teóricas, cirurgias experimentais, atividades cirúrgicas e infraestrutura das instituições participantes. RESULTADOS: Vinte e seis pós-graduandos (24,3%) estudavam em instituições credenciadas pelo MEC, 25 (23,4%) pelo CBO e 56 (52,3%) pelo CBO e MEC. A qualidade da preceptoria clínica, cirúrgica e na emergência mostrou-se satisfatória (86,0%, 87,0% e 67,3% respectivamente). As preceptorias clínica, cirúrgica e na emergência estiveram presentes em todos os turnos em 55,1%, 56,1% e 36,4%, respectivamente. A maioria dos alunos deseja maior oferta de cirurgias experimentais (75,7%), melhoria de recursos para o ensino (63,6%), dos equipamentos (74,8%) e das instalações físicas (67,3%). CONCLUSÃO: As variáveis analisadas foram similares nos serviços credenciados pelo MEC, CBO e por ambos.A qualidade das preceptorias nos serviços era satisfatória, embora não eram presenciais em todos os turnos em várias instituições. Os alunos sugeriram um aumento do volume cirúrgico e de cirurgias experimentais e melhoria na infraestrutura.


PURPOSE: Analyze residents' perception on ophthalmology training in Brazil by classifying the quality of attendings' supervision.Also, identify areas that need better investment. METHODS: This was a descriptive and transversal study that analyzed residents' opinion about Brazilian institutions accredited by the Ministry of Education and Culture (MEC) or by the Brazilian Council of Ophthalmology (CBO) or by both.A multiple-choice survey was applied to 107 residents to evaluate attendings' (clinical, surgical and in the emergency room) supervision, and the need of improvement in different areas such as, curriculum, amount/quality of surgical procedures, wetlabs and infrastructure. RESULTS: Twenty-six residents (24.3%) were from institutions accredited by MEC, 25 (23.4%) by CBO, and 56 (52.3%) by both, MEC and CBO. Attendings' supervision quality was considered satisfactory during surgeries (86,0%), clinical examinations (87,0%) and in the emergency room (67.3%). Full-time supervision was present in these departments in 55.1%, 56.1%, and 36.4%, respectively.Wetlabs, resources, equipments, and physical facilities were pointed as areas that need investment in 75.7%, 63.6%, 74.8%, and 67.3%, respectively. CONCLUSION: This study showed no statistical relevance between the different institutions' accreditation and the variables analyzed. In general, direct supervision in Brazilian institutions is satisfactory, although many are not full-time. Residents suggested increasing the number of surgeries and wetlabs, and investing in the institutions' infrastructure.


Asunto(s)
Humanos , Adulto , Oftalmología/educación , Curriculum/normas , Educación de Postgrado en Medicina/normas , Evaluación Educacional , Internado y Residencia , Preceptoría , Brasil , Encuestas y Cuestionarios
4.
Rev. bras. oftalmol ; 71(3): 149-154, maio-jun. 2012. ilus
Artículo en Inglés | LILACS | ID: lil-643911

RESUMEN

Five cases of intraocular lens (IOL) opacification in patients implanted with the Mediphacos Ioflex® IOL are described. Clinical data in each case was obtained from the patient's medical record. The five explanted IOLs underwent gross and light microscopic analysis. Selected lenses were processed for further evaluation and multiple sagittal cuts were stained with the alizarin red and von Kossa methods. Light microscope analysis confirmed the presence of deposits on and within the lens, which stained positive for calcium. The reason why calcification has occurred in these cases remains unclear, but surgeons should be aware of this potential late postoperative complication.


Cinco casos de opacificação de lente intraocular (LIO) em pacientes implantados com a LIO Ioflex® da Mediphacos são descritos. Os dados clínicos dos pacientes foram obtidos a partir dos prontuários médicos. As cinco LIOs explantadas foram enviadas para análise macroscópica e sob microscopia óptica. Algumas lentes foram processadas para análise adicional e múltiplos cortes sagitais foram corados pelos métodos de vermelho de alizarina e von Kossa. A análise sob microscopia óptica confirmou a presença de depósitos na superfície e no corpo da lente, que coraram positivamente para cálcio. A razão pela qual a calcificação ocorreu nestes casos permanece obscura. Entretanto, cirurgiões devem estar atentos para esta potencial complicação tardia.


Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Resinas Acrílicas/efectos adversos , Falla de Prótesis , Calcinosis/diagnóstico , Calcinosis/etiología , Lentes Intraoculares/efectos adversos , Microscopía , Complicaciones Posoperatorias , Reoperación , Agudeza Visual , Registros Médicos , Calcio/análisis , Facoemulsificación , Implantación de Lentes Intraoculares , Remoción de Dispositivos