Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Añadir filtros








Intervalo de año
1.
Chinese Critical Care Medicine ; (12): 1099-1100, 2023.
Artículo en Chino | WPRIM | ID: wpr-1010912

RESUMEN

Deep venipuncture catheterization is a routine and basic operation in the treatment of critically ill patients, and it is the most effective way to quickly correct the shock. Clinical B-ultrasound guided deep vein catheters can improve the success rate of puncture, but in the process of operation, the short axis needs to be replaced by the long axis. In the replacement process, the stability of the novice is insufficient, the positioning is difficult, and the operation time is too long. If only short axis puncture is used, it is impossible to know whether the current position of the puncture needle, and the puncture may be too deep and stray into the artery. The accuracy of the 45 degree angle of the injection point requires a very experienced operator. In view of the above shortcomings, doctors in the department of critical care medicine of Affiliated Hangzhou First People's Hospital, Zhejiang University School of Medicine designed a B-ultrasound puncture equipment, which has obtained the National Invention Patent of China (ZL 2016 1 0571557.X). The device is composed of B-ultrasound probe fixing frame, sliding scale plate, simulation slide rule, puncture needle, sliding device. By sliding device the angle of the pinhole channel, it is conducive to the accurate positioning of the puncture target, optimizing the operation procedure, improving the puncture speed and accuracy, effectively reducing the occurrence of puncture complications, ensuring patient safety, reducing unnecessary waste of human and material resources. It can reduce the workload of medical staff and is worthy of clinical practice.


Asunto(s)
Humanos , Cateterismo Venoso Central/métodos , Ultrasonografía Intervencional/métodos , Ultrasonografía , Punciones/métodos , Agujas
2.
Chinese Critical Care Medicine ; (12): 757-758, 2023.
Artículo en Chino | WPRIM | ID: wpr-982668

RESUMEN

Patients in the intensive care unit (ICU) often need to have various catheters placed on their bodies due to their severe condition. In order to prevent the occurrence of unplanned extubation, patients' hands should be restrained appropriately. The current restraint gloves used in clinical practice have problems such as improper restraint, easy falling off of oxygen saturation monitoring probes, and pressure injury of hands. Therefore, department of critical care medicine, Affiliated Hangzhou First People's Hospital, Zhejiang University School of Medicine designed a wrist restraint glove suitable for restless patients, and obtained the national utility model patent (ZL 2020 2 1612453.7). The device is composed of restraint gloves and restraint rings, which can not only restrain patients, but also continuously monitor the changes of blood oxygen saturation in patients with restfulness. This device is convenient to use, low cost, comfortable to wear, and can prevent the occurrence of device-related pressure injuries, which is suitable for clinical application.


Asunto(s)
Humanos , Muñeca , Unidades de Cuidados Intensivos , Cuidados Críticos , Mano , Extremidad Superior , Restricción Física
3.
Chinese Critical Care Medicine ; (12): 871-872, 2022.
Artículo en Chino | WPRIM | ID: wpr-956067

RESUMEN

Ventilator-associated pneumonia (VAP) is one of the most common infectious diseases in patients undergoing mechanical ventilation in intensive care unit (ICU). Although the use of closed sputum suction tube for sputum suction is the most common nursing measure for patients with tracheal intubation in ICU, and it is also an important measure to reduce the occurrence of VAP, the existing clinical technology still needs to use external flushing solution for humidification and flushing. In the process of use, the flushing operation has the risk that the amount of flushing fluid cannot be controlled, resulting in a large amount of flushing fluid entering the patient's airway, causing the patient to suffocate. The sputum attached to the wall of the sputum suction tube cannot be completely flushed, and the prolonged retention of the sputum leads to the proliferation of colonized bacteria, aggravating the infection of patients. Repeated pipe flushing not only increases consumables, but also increases the workload of medical staff. For this reason, the author has designed a fully enclosed sputum suction tube flushing device, which has obtained the National Utility Model Patent of China (patent number: CN 2019 2 1198740.5). This device is an integrated design, and the materials used for sputum suction, humidification and flushing are fully enclosed, without air exposure, and can be operated strictly without bacteria. Pulse flushing with syringe can clean the sputum attached to the inner wall and reduce the incidence of VAP. The volume of flushing fluid can be effectively controlled during use to ensure patient safety and reduce waste. It is worth popularizing and applying in clinical practice to optimize the operation steps and reduce the workload of medical staff.

4.
Chinese Journal of Practical Nursing ; (36): 2673-2677, 2022.
Artículo en Chino | WPRIM | ID: wpr-955067

RESUMEN

Objective:A foot cleaning device for bedridden patients in ICU was made, and its application effects in foot cleaning for bedridden patients in ICU was discussed.Methods:A total of 200 inpatients in the department of ICU from April 2021 to October 2021 were selected as the research objects.According to the random number table, the patients were divided into two groups, including 100 patients in the control group and 100 patients in the experimental group.The patients in the control group used an ordinary foot basin and dipped warm water by a towel for foot wiping and cleaning. The patients in the experimental group used a foot cleaning device for bedridden patients developed and designed by our hospital. Both groups received warm water foot bath for 20 minutes after cleaning. The incidence of adverse events, average foot washing time, total foot washing time, the subjective comfort and satisfaction of the patients and the satisfaction of the operator were observed.Results:The incidence of adverse events during foot cleaning in the experimental group was 2.00%(28/1 400) lower than 4.36%(61/1 400) in the control group, the difference was statistically significant ( χ2=11.88, P<0.05). The foot washing time in the observation group [(27.77 ± 1.34) min] was longer than that in the control group [(24.63 ± 2.36) min], the difference was statistically significant ( t=9.30, P<0.05). The total foot washing time in the observation group [(27.77 ± 1.34) min] was shorter than that in the control group [(49.26 ± 4.71)min], the difference was statistically significant ( t=42.51, P<0.05). The subjective comfort of foot cleaning, the satisfaction of foot cleaning of patients and the satisfaction of foot cleaning operators in the experimental group were 91.00 (91/100) , 97.00% (97/100) , 91.67% (55/60) , while the control group were 75.00% (75/100) 、85.00% (85/100) , 75.00% (45/60) , and the differences between the two groups were statistically significant ( Z=-3.04, -4.82, -2.71, all P<0.05). Conclusions:The self made foot cleaning device for bedridden patients in this study can be used in ICU patients. It can effectively reduce the incidence of adverse events in the process of foot washing and shorten the time of foot washing. It can also improve the comfort and satisfaction of patients, and improve the satisfaction of operators.

5.
Chinese Journal of Practical Nursing ; (36): 1472-1475, 2022.
Artículo en Chino | WPRIM | ID: wpr-954877

RESUMEN

Objective:To investigate the application effect of rapid leg circumference positioning measuring device in critical ill patients.Methods:From August 2021 to November 2021, selected 50 patients in ICU of Hangzhou First People′s Hospital. Two methods to measure the leg circumference of the same patient at the same time were used. The traditional method used a tape measure to measure the leg circumference, while the improved method used the rapid positioning and measuring device of leg circumference to measure the leg circumference. the average total positioning time, average total measurement time, average measurement difference and nurses′ satisfaction were compared.Results:The total positioning time and total measurement time of the improved method were respectively (15.2 ± 3.3) s and (34.0 ± 3.9) s, which were shorter than the traditional method (29.0 ± 3.1) s, (79.1 ± 4.9) s, the differences were statistically significant ( t=50.93, 21.43, P<0.05). The measured data difference between 15 cm above patella and 10 cm below patella of the improved method was (1.27 ± 0.67) mm, (0.93 ± 0.31) mm, which were less than the traditional method (8.82 ± 3.28) mm and (7.94 ± 2.11) mm, the differences were statistically significant ( t=28.66, 23.42, P<0.05). Nurses′satisfaction in the improved method was 96.0% (48/50), which was higher than 36% (18/50) in the traditional method, and the difference was statistically significant ( Z=5.78, P<0.05). Conclusions:The leg circumference measurement device designed in this study can effectively save the leg circumference measurement time, quickly and accurately, increase the comfort of patients and improve the satisfaction of patients and nursing staff. It is worthy of clinical application.

6.
Chinese Journal of Practical Nursing ; (36): 1514-1518, 2019.
Artículo en Chino | WPRIM | ID: wpr-803071

RESUMEN

Patients with coronary heart disease have recurrent cardiovascular events after systemic treatment is often one of the leading factors increasing the death and hospitalization rates, thereby adding to the economic burden of society. According to foreign and domestic reports, poor compliance of cardiac rehabilitation in patients with coronary heart disease is a common problem at present. Therefore, in the rehabilitation of patients with coronary heart disease, Improving cardiac rehabilitation compliance is important in regaining health and cost saving during coronary heart disease recovery treatment. This study summarized the status and influence factors of cardiac rehabilitation compliance among foreign and domestic coronary heart disease patients and the interventions recommended for improving cardiac rehabilitation compliance.

7.
Chinese Journal of Practical Nursing ; (36): 1514-1518, 2019.
Artículo en Chino | WPRIM | ID: wpr-752677

RESUMEN

Patients with coronary heart disease have recurrent cardiovascular events after systemic treatment is often one of the leading factors increasing the death and hospitalization rates,thereby adding to the economic burden of society. According to foreign and domestic reports, poor compliance of cardiac rehabilitation in patients with coronary heart disease is a common problem at present. Therefore, in the rehabilitation of patients with coronary heart disease,Improving cardiac rehabilitation compliance is important in regaining health and cost saving during coronary heart disease recovery treatment. This study summarized the status and influence factors of cardiac rehabilitation compliance among foreign and domestic coronary heart disease patients and the interventions recommended for improving cardiac rehabilitation compliance.

8.
Chinese Journal of Behavioral Medicine and Brain Science ; (12): 719-721, 2013.
Artículo en Chino | WPRIM | ID: wpr-441906

RESUMEN

Objective To explore the correlation of personality traits of dependence,self-criticism and childhood abuse in patients with major depression.Methods As a case-control study,80 patients with major depression and 80 normal controls took apart in this study.They were separately evaluated by Hamilton Depression Scale (HAMD),depressive experiences questionnaire (DEQ) and child abuse questionnaire (CTQ).Results Each factor scores of dependency (90.77 ± 14.54) and self-criticism (68.00 ± 15.02) in patients with major depression were significantly higher than that in normal control group (77.96 ± 11.81,50.02 ± 10.38,P<0.05).Dependence was significantly positive correlated with physical abuse,emotional neglect and physical neglect (P <0.05); and self-criticism were significantly positive correlated with emotional abuse,physical abuse,emotional neglect and physical neglect (P< 0.05).Stepwise multiple linear regression analysis showed that dependence,selfcriticism could directly predict depressive symptoms respectively (β =0.283,P < 0.05),(β =0.284,P < 0.05),and emotional abuse could affect depressive symptoms by intermediation of dependency and self-criticism.Conclusion Emotional abuse can impact on depressive symptoms indirectly by dependent and self-criticism personality traits which suggest personality traits of dependency and self-criticism probably play an intermediate effect role between childhood abuse and major depression.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA