Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Journal of Southern Medical University ; (12): 128-132, 2009.
Artículo en Chino | WPRIM | ID: wpr-339047

RESUMEN

<p><b>OBJECTIVE</b>To compare the efficacy and safety of segmental pulmonary vein isolation (SPVI) and circumferential pulmonary vein isolation (CPVI) guided by EnSite NavX system in patients with atrial fibrillation (AF).</p><p><b>METHODS</b>Eighty-five patients with paroxysmal AF and persistent AF were enrolled in this study. Forty patients (30 with paroxysmal AF and 10 with persistent AF) underwent SPVI procedure, and 45 (31 with paroxysmal AF and 14 with persistent AF) underwent CPVA guided by EnSite NavX three-dimensional electrophysiological mapping system. All the patients were followed up for over six months.</p><p><b>RESULTS</b>The success rate was 65% in the SPVI group and 84.4% in the CPVI group (P=0.0332), with incidence of major complications of 17.5% and 6.7%, respectively (P=0.0845). In the SPVI group, 12.5% patients had pulmonary vein stenosis after the operation, which occurred in none of the patients in the CPVI group (P=0.0312). The total procedure time was 200.4+/-37.0 min in the SPVI group, significantly shorter than that in the CPVI group (226.5+/-26.1 min, P=0.002). The fluoroscopy time in the SPVI group was obviously longer than that in the CPVI group (54.7+/-9.7 vs 27.1+/-3.1 min, P<0.001).</p><p><b>CONCLUSIONS</b>CPVI guided by EnSite NavX system is more effective than SPVI for treatment of atrial fibrillation with significantly shortened fluoroscopy time but prolonged procedure time. The two procedures results in comparable incidences of major complications, but CPVI is associated with reduced rate of pulmonary vein stenosis in comparison with SPVI.</p>


Asunto(s)
Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fibrilación Atrial , Cirugía General , Ablación por Catéter , Métodos , Técnicas Electrofisiológicas Cardíacas , Métodos , Estudios de Seguimiento , Venas Pulmonares , Cirugía General
2.
Journal of Southern Medical University ; (12): 1273-1275, 2008.
Artículo en Chino | WPRIM | ID: wpr-270157

RESUMEN

<p><b>OBJECTIVE</b>To investigate the efficacy and safety of circumferential pulmonary vein ostial isolation guided by EnSite NavX three-dimensional electrophysiological mapping in patients with atrial fibrillation (AF).</p><p><b>METHODS</b>Thirty-eight patients with drug refractory paroxysmal or persistent AF underwent circumferential pulmonary vein ostial isolation and were followed up to investigate the efficacy and safety of the treatment.</p><p><b>RESULTS</b>All cases reached the endpoint of the ablation, and both sides of the pulmonary vein were completely isolated, with an average procedure time of 200.4-/+37.0 min, X-ray exposure time of 54.7-/+9.7 min, and three-dimensional left atrial geometry reconstruction time of 27.5-/+7.5 min. During the follow-up for 9-/+3 months, the success rate of initial ablation was 89.5%, and the incidence of procedure-related complications were 7.9%.</p><p><b>CONCLUSIONS</b>Circumferential pulmonary vein ostial isolation guided by EnSite NavX three-dimensional electrophysiological mapping can be effective and safe for AF treatment.</p>


Asunto(s)
Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fibrilación Atrial , Cirugía General , Ablación por Catéter , Métodos , Técnicas Electrofisiológicas Cardíacas , Métodos , Venas Pulmonares , Cirugía General , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA