Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Chinese Journal of Endocrinology and Metabolism ; (12): 345-352, 2023.
Artículo en Chino | WPRIM | ID: wpr-994332

RESUMEN

Objective:To identify the genetic variation in a mucopolysaccharidosis type Ⅱ(MPS Ⅱ)family, and conduct a functional study of iduronate-2-sulfatase(IDS): c.323A>C.Methods:A five-generation MPS Ⅱ family of 83 individuals including 4 patients from northern China was collected. Urine mucopolysaccharide and Alder-Reilly body were tested to assist the clinical diagnosis of MPS Ⅱ. IDS enzyme activity was detected on core family members. By the whole exome sequencing of a MPS Ⅱ patient in this family and bioinformatics analysis, the variant was screened and further identified by PCR-Sanger sequencing. Finally, to validate the function of the variant in vitro, the wild-type IDS overexpression plasmid(pCMV-hIDS-WT)and the IDS overexpression plasmid carrying the mutation site(pCMV-hIDS-c.323A>C)were transfected into COS-7 cells and the IDS activity was detected. Results:The proband(Ⅳ3)and Ⅳ4 were diagnosed as MPS Ⅱ by urine mucopolysaccharide, Alder-Reilly body, and IDS enzyme activity tests. Ⅳ3, Ⅳ4, Ⅲ19, and Ⅲ32 were determined to carry IDS: c.323A>C missense variant through the whole-exome sequencing, and diagnosed as MPS Ⅱ. Meanwhile, Ⅱ2, Ⅱ4, Ⅱ8, Ⅱ12, Ⅱ14, Ⅲ5, Ⅲ7, Ⅳ14 in the MPS Ⅱ family carried IDS: c.323A>C missense variant, and were excluded as MPS Ⅱ. The in vitro experiment in COS-7 cells showed that the missense mutation led to a significant decrease in IDS enzyme activity. Conclusion:The variant IDS: c.323A>C: p.Y108S significantly decreases the activity of IDS enzyme in vivo and in vitro, and it is identified as a pathogenic variant for MPS Ⅱ.

2.
Chinese Journal of Orthopaedic Trauma ; (12): 702-710, 2023.
Artículo en Chino | WPRIM | ID: wpr-992770

RESUMEN

Objective:To compare 3D-printing-assisted surgery and conventional surgery in the treatment of Schazker type Ⅵ tibial plateau fractures.Methods:A retrospective study was conducted to analyze the clinical data of 50 patients with type Ⅵ tibial plateau fracture who had been treated from January 2019 to December 2021 at the 5 Departments of Orthopedics in The First Affiliated Hospital of Nanchang University, The First People's Hospital of Jiujiang, Pingkuang General Hospital, Ganzhou People's Hospital, and Nanchang Hongdu Hospital of Traditional Chinese Medicine. The patients were divided into 2 groups according to their different treatment methods. In the 3D printing group of 25 cases treated by 3D-printing-assisted surgery, there were 14 males and 11 females, with an age of (42.5±9.1) years; in the conventional group of 25 cases treated by conventional surgery, there were 13 males and 12 females with an age of (42.2±9.3) years. The 2 groups were compared in terms of operation time, intraoperative blood loss, intraoperative fluoroscopy frequency, fracture healing time, postoperative complications, the Rasmussen radiological scores and the American Hospital for Special Surgery (HSS) knee function scores at 6 and 12 months after operation.Results:There was no significant difference in the preoperative general data between the 2 groups, indicating comparability ( P>0.05). The operation time [(125.4±10.6) min], intraoperative blood loss [(206.2±16.3) mL], intraoperative fluoroscopy frequency [(9.2±2.7) times] and fracture healing time [(3.0±0.7) months] in the 3D printing group were all significantly less than those in the conventional group [(168.2±14.1) min, (303.2±20.4) mL, (15.5±3.5) times and (4.1±0.8) months] while the Rasmussen radiological scores (17.6±1.2 and 17.9±0.6) and HSS knee scores (90.8±6.4 and 91.5±5.6) at 6 and 12 months after operation in the 3D printing group were all significantly higher than those in the conventional group (16.2±2.6 and 16.7±2.2; 84.5±9.2 and 87.6±8.0) (all P<0.05). In the 3D printing group, there were 1 case of wound infection and 1 case of wound dehiscence after operation. In the conventional group, there were 2 cases of wound skin necrosis, 3 cases of wound dehiscence, 1 case of traumatic arthritis, 2 cases of wound infection, and 1 case of screw loosening. The incidence of complications in the 3D printing group (8.0%, 2/28) was significantly lower than that in the conventional group (36.0%, 9/25) ( P<0.05). Conclusion:In the treatment of Schatzker type VI tibial plateau fractures, compared with conventional surgery, 3D-printing-assisted surgery can lead to better curative outcomes, because it is conducive to lowering surgical difficulty, reducing postoperative complications, and promoting fracture union and functional recovery of the knee.

3.
Journal of Biomedical Engineering ; (6): 682-713, 2014.
Artículo en Chino | WPRIM | ID: wpr-290693

RESUMEN

It is difficult to reflect the properties of samples from the signal directly collected by the low field nuclear magnetic resonance (NMR) analyzer. People must obtain the relationship between the relaxation time and the original signal amplitude of every relaxation component by inversion algorithm. Consequently, the technology of T2 spectrum inversion is crucial to the application of NMR data. This study optimized the regularization factor selection method and presented the regularization algorithm for inversion of low field NMR relaxation distribution, which is based on the regularization theory of ill-posed inverse problem. The results of numerical simulation experiments by Matlab7.0 showed that this method could effectively analyze and process the NMR relaxation data.


Asunto(s)
Humanos , Algoritmos , Espectroscopía de Resonancia Magnética
4.
Chinese Journal of Medical Instrumentation ; (6): 222-224, 2012.
Artículo en Chino | WPRIM | ID: wpr-342966

RESUMEN

In clinical practice, incubators can contribute to better diagnosis and treatment of diseases. Currently, insulation medical equipment used for the newborn are mainly warm-boxes. With the use popularity of warm-boxes in the country, medical accidents caused by improper use are on the increase. According to neonatal insulation technology and standardized management of practice, this article puts forward technical requirements of infant incubators with constant temperature and humidity, operation regulations and management specifications to better regulate the use of such devices. Meanwhile, it also suggests national related departments to formulate "incubator technology management norms" and "warm-box technology and practice", intending to standardize industry behaviors and ensure medical safety.


Asunto(s)
Humanos , Recién Nacido , Incubadoras para Lactantes , Estándares de Referencia , Administración de Materiales de Hospital , Administración de la Seguridad , Temperatura
5.
Journal of Biomedical Engineering ; (6): 465-470, 2009.
Artículo en Chino | WPRIM | ID: wpr-280175

RESUMEN

The homogeneity of magnetic field is a key parameter in nuclear magnetic resonance system (NMRI); it can be refined by active shimming. In this work, the authors analyze the theory of active shimming, carry out data processing and simulation, and design an active shimming system which can work on permanent mini-type MRI system. The shimming coils are placed on both out-sides of the receiving shielding box, so the gap of the coils is constant. The system improves the homogeneity of magnetic field (i. e. the decrease of heterogeneity from 10 ppm to 1.4 ppm) on NMI20 mini-type MRI instrument.


Asunto(s)
Algoritmos , Campos Electromagnéticos , Diseño de Equipo , Métodos , Imagen por Resonancia Magnética , Métodos , Modelos Teóricos
6.
Chinese Journal of Practical Nursing ; (36)2006.
Artículo en Chino | WPRIM | ID: wpr-528400

RESUMEN

Objective To evaluate the clinical values of the TR band, analyze the factors about the hemorrhage delay at the same time. Methods Divided 98 patients who had accepted the radial artery interventional radiology into the observation group (52 cases) and the control group (46 cases) randomly. The TR band was used in the observation group and the routine nursing method was used in the control group. Results The incidence rate of complication in the observation group was significant lower than that of in the control group,P

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA