Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Artículo en Chino | WPRIM | ID: wpr-1021145

RESUMEN

Objective To explore the feasibility and clinical outcome of lateral cervical incision via sternocleidomastoid intermuscular approach(SMIA)in the treatment of primary hyperparathyroidism.Methods The clinical data of 64 patients with primary hyperparathyroidism who underwent unilateral parathyroid surgery in the First Affiliated Hospital,School of Medicine of Zhejiang University from January 2019 to June 2022 were retrospectively analyzed.They were divided into lateral cervical incision via sternocleidomastoid intermuscular approach group(SMIA group)and linea alba cervicalis approach group(LACA group)based on the surgical incision and access route.The differences in clinical features,surgery-related outcomes and postoperative functions of the anterior cervical region were compared between the two groups.The EQ-5D-5L scale was used to assess the subjective feeling of postoperative neck discomfort,while the Hollander Wound Assessment Scale was used to assess the clinical outcome of incision healing.Results There were no statistical differences between the two groups of patients in terms of age,gender,intraoperative bleeding,parathyroid hormone or blood calcium levels before and after surgery(P>0.05).The duration of surgery was significantly shorter in the SMIA group than in the LACA group[(39.77±5.69)min vs.(54.41±4.66)min].There was a statistical difference between the two groups in functional protection of the anterior cervical region at 1 month and 12 months after surgery(1 month,84.67±3.74 vs.79.47±5.38,P<0.001;12 months,93.80±2.52 vs.89.94±2.39,P<0.001),and the SMIA group was better than the LACA group.The Hollander Incision Assessment Scale scores of the SMIA group were better than those of the LACA group at 6 months and 12 months after surgery,and the difference was statistically significant(6 months,1.93±0.58 vs.2.41±0.66,P=0.003;12 months,1.03±0.67 vs.1.74±0.62,P<0.001).Conclusion Parathyroidectomy via sternocleidomastoid intermuscular approach through lateral cervical incision is a simple,safe and effective surgical procedure,which makes it easier to search for parathyroid lesions and shortens the surgical time compared with the traditional incision,and has obvious advantages in the protection of anterior cervical region function.

2.
Artículo en Chino | WPRIM | ID: wpr-408258

RESUMEN

OBJECTIVE: The success of joint prosthesis greatly depends on the materials, which should be a perfect combination of physics, chemistry, biomechanics and clinical sciences in choice of them. In addition, the effect of manufacture technology can not be neglected. So, it is significant to probe into the systematic basis in materials selection of joint prosthesis.DATA SOURCES: A computer-based search was conducted in Pubmed database for articles about joint prosthesis published before April 2006 with the key words of "artificial joint materials, biomaterial", and the language was limited to English. Meanwhile, Chinese Journal Full-text Database (CJFD) and Wanfang database were looked for relevant literatures published before April 2006 with the key words of "artificial joint material, biomedical material", and the language was limited to Chinese. Besides,the standards for materials were searched in Chinese service net for standard consultation with the key words of "implants for surgery" in both Chinese and English. At the same time, relevant books were also manually searched.STUDY SELECTION: Data were checked in the first trial, and related articles according to the criteria of research were looked for the full text.Inclusion criteria: ① Requirements for artificial joint material. ② Relevant standards for artificial joint of surgical implants. Exclusion criteria: Repetitive studies were excluded.DATA EXTRACTION: A total of 390 domestic and overseas articles,which were in relation to the mechanical properties of artificial joint material and bone and measurement of the overall dimensions of knee joint,were collected. There were still 242 relevant standards, while the repetitive studies and similar researches were excluded. Ten typical articles and 25 standards in collection were summed up and reviewed.DATA SYNTHESIS: ①Close combination of physics, chemistry, biomechanics and clinical sciences is sufficiently embodied in the selection of the materials. ② Two aspects must be taken into consideration: Requirements for function of the implant and the responses inside the human body.③ Main types of materials for joint prosthesis: biomedical metallic material, biomedical inorganic material of nonmetal, bioceramic, biomedical compound materials and so on. All kinds of materials that have been adopted should accord with the international or state or trade standards.④ The final determination of materials should meet the comprehensive requirements of standards, laws and regulations, as well as strategic targeting. CONCLUSION: Based on engineering, the fundamental principles of materials selection for joint prosthesis are illustrated from the following angles: clinical requirements for materials of replacement, attentions in joint prosthesis design, commonly used biomedicine materials performance, requirements of product registration and laws & regulations related to the materials, the strategy in the choice of material standard etc. As a result, a valuable system approach is provided for joint-prosthesis designers to select materials.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA