Journal of Public Health and Preventive Medicine ; (6): 43-47, 2021.
Artículo en Chino | WPRIM | ID: wpr-886822

RESUMEN

Objective To investigate the source of microbial contamination in the clean room of the workshop. Methods Microbiological sampling was carried out from the air, environment and personnel of the workshop. The samples were cultivated, the microorganisms were detected by MALDI-TOF-MS, and homology analysis was performed with the microbial identification system of the instrument. Results A total of 14 species and 41 strains of bacteria were detected. Nine strains of Staphylococcus epidermidis were selected for homology analysis, and the Staphylococcus epidermidis from personnel gloves and headgear had 94% homology. There was 83% homology among the staphylococcus epidermidis derived from the sedimentation bacteria, the ground environment and personnel, which was higher than the 71% of the standard strain. Conclusion The homology analysis demonstrates that the pollution in the clean room of the workshop mainly comes from personnel, and secondly comes from the environment outside the workshop. Enterprises need to strengthen management to prevent the occurrence of microbial contamination. MALDI-TOF-MS can be used for rapid detection of complex environmental bacteria and for homology analysis.