RESUMEN
OBJECTIVES@#To establish a method for the detection of carbamazepine and its metabolites 10,11-dihydro-10,11-epoxycarbamazepine and 10,11-dihydro-10-hydroxycarbamazepine in blood samples by liquid chromatography-tandem mass spectrometry (LC-MS/MS).@*METHODS@#The blood samples were treated with 1-butyl-3-methylimidazolium hexafluorophosphate as an extraction solvent. The samples were extracted by ultrasound-assisted extraction and separated by ZORBAX Eclipse Plus C18, 95Å column. The mobile phase A aqueous solution containing 0.1% formic acid and 10 mmol/L ammonium acetate, and mobile phase B mixed organic solvent containing acetonitrile/methanol (Vacetonitrile∶Vmethanol=2∶3) were used for gradient elution at the flow rate of 1.00 mL/min. An electrospray ion source in positive mode was used for detection in the multiple reaction monitoring.@*RESULTS@#The linearities of carbamazepine and its metabolites 10,11-dihydro-10,11-epoxycarbamazepine and 10,11-dihydro-10-hydroxycarbamazepine in blood samples were good within the corresponding range, with correlation coefficients (r) greater than 0.995 6. The limits of detection were 3.00, 0.40 and 1.30 ng/mL, respectively. The limit of quantitation were 8.00, 1.00 and 5.00 ng/mL, respectively. The extraction recoveries ranged from 76.00% to 106.44%. The relative standard deviations of the intra-day and inter-day precisions were less than 16%. Carbamazepine and its main metabolite 10,11-dihydro-10,11-epoxycarbamazepine were detected in blood samples of death cases with a mass concentration of 2.71 μg/mL and 252.14 ng/mL, respectively.@*CONCLUSIONS@#This method has high sensitivity and good selectivity, which is suitable for the detection of carbamazepine and its metabolites in blood samples, and can be used for carbamazepine-related forensic identifications.
Asunto(s)
Cromatografía Liquida/métodos , Espectrometría de Masas en Tándem , Metanol , Carbamazepina/análisis , Benzodiazepinas/análisis , Solventes , Cromatografía Líquida de Alta Presión , Extracción en Fase SólidaRESUMEN
OBJECTIVE@#To evaluate the necessity and suitability of the anti-HCV ELISA teot gray zone setted up by 7 blood station laboratories.@*METHODS@#7 blood station laboratories were coded as 1, 2, 3, 4, 5, 6 and 7 respectively; 8 kinds of ELISA reagents were coded as A, B, C, D, E, F, G and H respectively. 1 or 2 of 8 ELISA reagents produced by different manufactories were used to detect the anti-HCV in specimens of same group by 7 blood station laboratories; the Westen blot was used to detect the specimens with difference of detected results so as to difine the serological status of specimens. The true positive rate of specimens detected by laboratories and gray zone-comfirined positive rate of specimens were accounted so as to analyze the necessity of setting up the gray zone for anti-HCV ELISA test of 7 blood station laboratories; the optimal cut-off value for anti-HCV ELISA test was determined in 7 blood station laborafories by ROC curve and the changes of sensitivity and specificity of 3 different cut-off value(laboratory work cut-off value, manifactory-recommended cun-off value and optimal cut-off value) were compared so as to analyze the suitability of gray zone for anti-HCV ELISA test in 7 blood station laboratories.@*RESULTS@#The true positive rate detected by 7 blood station laboratories, out of which coded 1 laboratory used 2 kinds of coded A, B reagents was 95.40%(1A), 99.23% (1B), 94.25% (2C), 96.17% (3D), 98.08% (4E), 96.93% (5F), 97.32%(6G) and 93.10%(7H). Except for 2C(94.25%) and 7H(93.10%), the true positive rate detected by laboratoies which not sutted up gray zone, the gray zone-con-firmed positive rate in 6 blood station laboratories setted up gray zone: was 0.00%, 0.00%, 21.43%, 0.00%, 0.00%, 0.00% and 38.89%. The comparison of 3 different cut-off valuces by ROC curve showed that the anti-HCV cut-off values in 5 laboratories(1B, 2C, 4E, 5F and 6G) were as follows: optimal cut-off value>manufactory recommeded cut-off value>laboratory work cut-off value, thus use of manufactory-recommeded cut-off value abreadly has reached the high sensitivity requinements for laboratory screening; however, the optimal cut-off value in laboratories 1A, 3B and 7H, thas the appropriate gray zone should be used. In 6 laboratories setting up gray zone, the gensitivity in 3D, 7H laboratories only a little improved (1.60% and 2.70% raspectively) in Eamparison between laboratory work cut-off value and manufactorg-recommeded cut-off value; moreover, the sensitivity in other laboratories not is changed, but the specificity decreased (0.20%-0.50%).@*CONCLUSION@#In addition to setting up the appropriate gray zone in laboratories 1A, 3D and 5H, the gray zone in other laboratories may be cancelled. Even in the same laboratory, the setting up the gray zone also should be scientifically assessed, the same scale cannot be blindly used, thus appropniate strategies should be established.