1.
Chinese Journal of Medical Instrumentation ; (6): 167-169, 2002.
Artículo en Chino | WPRIM | ID: wpr-344265

RESUMEN

Focused Ultrasound Surgery (FUS) is a promising minimally invasive technique in tissue ablation. Because of the high intensity at the ultrasound focus, a precise 3D-localization system is required to determine the site of the treating target in order to increase the efficiency and security of FUS. This paper represents a three dimensional ultrasound (3D US) localization system developed and its workflow. The system is mainly composed of imaging and image processing system, movement device and its controlling circuits, and position feedback device. The system has a maximum scan range of +/- 30 degrees with a resolution of 8 levels from 0.54' to 0.36 degrees. For a spherical shape like target, in theory, the maximum diameter is 160 mm the system can treat. The system can be used to localize precisely the treatment targets with general sizes in the suitable parts of the body in FUS.


Asunto(s)
Humanos , Algoritmos , Procesamiento Automatizado de Datos , Simulación por Computador , Diseño de Equipo , Procesamiento de Imagen Asistido por Computador , Métodos , Imagenología Tridimensional , Microcomputadores , Cirugía Asistida por Computador , Métodos , Terapia por Ultrasonido , Métodos
2.
Chinese Journal of Medical Instrumentation ; (6): 410-413, 2002.
Artículo en Chino | WPRIM | ID: wpr-344244

RESUMEN

The development of a RF ablation therapeutic instrument based on improved PID algorithm is introduced here. It is based on the theory of radio frequency local destruction. By adopting the improved PID temperature control algorithm, the problem of the temperature control precision reduction due to tumor tissue characteristic changing by heating has been solved, thus ensuring homogeneous and smooth radio frequency heating to tumor foci. Experiments demonstrate that the new algorithm has strong adaptability and anti-disturbance capability, the equipment works stably and reliably, and can control therapeutic temperature precisely (+/- 2 degrees C), which indicates a good clinical application value.


Asunto(s)
Humanos , Algoritmos , Calorimetría , Métodos , Ablación por Catéter , Métodos , Electrodos , Diseño de Equipo , Hipertermia Inducida , Métodos , Almacenamiento y Recuperación de la Información , Neoplasias , Terapéutica , Programas Informáticos , Temperatura