Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
1.
Beijing Da Xue Xue Bao ; (6): 174-180, 2023.
Artículo en Chino | WPRIM | ID: wpr-971292

RESUMEN

OBJECTIVE@#To explore an efficient and automatic method for determining the anatomical landmarks of three-dimensional(3D) mandibular data, and to preliminarily evaluate the performance of the method.@*METHODS@#The CT data of 40 patients with normal craniofacial morphology were collected (among them, 30 cases were used to establish the 3D mandibular average model, and 10 cases were used as test datasets to validate the performance of this method in determining the mandibular landmarks), and the 3D mandibular data were reconstructed in Mimics software. Among the 40 cases of mandibular data after the 3D reconstruction, 30 cases that were more similar to the mean value of Chinese mandibular features were selected, and the size of the mandibular data of 30 cases was normalized based on the Procrustes analysis algorithm in MATLAB software. Then, in the Geomagic Wrap software, the 3D mandibular average shape model of the above 30 mandibular data was constructed. Through symmetry processing, curvature sampling, index marking and other processing procedures, a 3D mandible structured template with 18 996 semi-landmarks and 19 indexed mandibular anatomical landmarks were constructed. The open source non-rigid registration algorithm program Meshmonk was used to match the 3D mandible template constructed above with the tested patient's 3D mandible data through non-rigid deformation, and 19 anatomical landmark positions of the patient's 3D mandible data were obtained. The accuracy of the research method was evaluated by comparing the distance error of the landmarks manually marked by stomatological experts with the landmarks marked by the method of this research.@*RESULTS@#The method of this study was applied to the data of 10 patients with normal mandibular morphology. The average distance error of 19 landmarks was 1.42 mm, of which the minimum errors were the apex of the coracoid process [right: (1.01±0.44) mm; left: (0.56±0.14) mm] and maximum errors were the anterior edge of the lowest point of anterior ramus [right: (2.52±0.95) mm; left: (2.57±1.10) mm], the average distance error of the midline landmarks was (1.15±0.60) mm, and the average distance error of the bilateral landmarks was (1.51±0.67) mm.@*CONCLUSION@#The automatic determination method of 3D mandibular anatomical landmarks based on 3D mandibular average shape model and non-rigid registration algorithm established in this study can effectively improve the efficiency of automatic labeling of 3D mandibular data features. The automatic determination of anatomical landmarks can basically meet the needs of oral clinical applications, and the labeling effect of deformed mandible data needs to be further tested.


Asunto(s)
Humanos , Imagenología Tridimensional/métodos , Mandíbula/diagnóstico por imagen , Programas Informáticos , Algoritmos , Puntos Anatómicos de Referencia/anatomía & histología
2.
Chinese Journal of Stomatology ; (12): 414-421, 2023.
Artículo en Chino | WPRIM | ID: wpr-986088

RESUMEN

Objective: To provide a new solution for the digital design of nasal prostheses, this study explores the three-dimensional (3D) facial morphology completion method for external nasal defects based on the non-rigid registration process of 3D face template. Methods: A total of 20 male patients with tooth defect and dentition defect who visited the Department of Prosthodontics, Peking University School and Hospital of Stomatology from June to December 2022 were selected, age 18-45 years old. The original 3D facial data of patients were collected, and the 3D facial data of the external nose defect was constructed in Geomagic Wrap 2021 software. Using the structured 3D face template data constructed in the previous research of the research group, the 3D face template was deformed and registered to the 3D facial data of external nose defect (based on the morphology of non-defective area) by non-rigid registration algorithm (MeshMonk program), and the personalized deformed data of the 3D face template was obtained, as the complemented facial 3D data. Based on the defect boundary of the 3D facial data of the external nose defect, the complemented external nose 3D data can be cut out from the complemented facial 3D data. Then the nasofacial angle and nasolabial angle of the complemented facial 3D data and the original 3D facial data was compared and analyzed, the ratio between the nose length and mid-face height, nose width and medial canthal distance of the complemented facial 3D data was measured, the edge fit between the edge curve of the complemented external nose 3D data and the defect edge curve of the 3D facial data of external nose defect was evaluated, and the morphological difference of the nose between the complemented external nose 3D data and the original 3D facial data was analyzed. Results: There was no significant statistically difference (t=-0.23, P=0.823; Z=-1.72, P=0.086) in the nasofacial angle (28.2°±2.9°, 28.4°±3.5° respectively) and nasolabial angle [95.4°(19.2°), 99.9°(9.5°) respectively] between the 20 original 3D facial data and the complemented facial 3D data. The value of the ratio of nose length to mid-face height in the complemented facial 3D data was 0.63±0.03, and the value of the ratio of nose width to medial canthal distance was 1.07±0.08. The curve deviation (root mean square value) between the edge curve of the complemented external nose 3D data and the defect edge curve of the 3D facial data of external nose defect was (0.37±0.09) mm, the maximum deviation was (1.14±0.32) mm, and the proportion of the curve deviation value within±1 mm was (97±3)%. The distance of corresponding nose landmarks between the complemented facial 3D data and the original 3D facial data were respectively, Nasion: [1.52(1.92)] mm; Pronasale: (3.27±1.21) mm; Subnasale: (1.99±1.09) mm; Right Alare: (2.64±1.34) mm; Left Alare: (2.42± 1.38) mm. Conclusions: The method of 3D facial morphology completion of external nose defect proposed in this study has good feasibility. The constructed complemented external nose 3D data has good facial coordination and edge fit, and the morphology is close to the nose morphology of the original 3D facial data.

3.
Chinese Journal of Stomatology ; (12): 435-441, 2023.
Artículo en Chino | WPRIM | ID: wpr-986091

RESUMEN

Objective: To explore a method for digitally designing and fabricating a sequential tooth-sectioning guide that can assist in the extraction of mandibular horizontal impacted third molars, preliminarily evaluate its feasibility and provide a reference for clinical application. Methods: Twenty patients with mandibular low level impacted third molars who visited the Department of General Dentistry, Peking University School and Hospital of Stomatology from March 2021 to January 2022 were selected. Cone-beam CT showed direct contact between the roots and mandibular canal, and full range impressions of the patients' intraoral teeth were taken and optical scans of the dental model were performed. The patients' cone-beam CT data and optical scan data were reconstructed in three dimensions, anatomical structure extraction, registration fusion, and the design of the structure of the guide (including crown-sectioning guide and root-sectioning guide) by Mimics 24.0, Geomagic Wrap 2021, and Magics 21.0 software, and then the titanium guide was three dimension printed, and the guide was tried on the dental model. After confirmation, the guide was used to assist the dentist in the operation. We observed whether the guide was in place, the number of tooth splitting, the matching of tooth splitting with the preoperative design, the operation time, and whether there were any complications. Results: In this study, 20 sectioning guides were successfully printed, all of them were well fitted in the patients' mouth, the average number of section was 3.4 times, the tooth parts was better matched with the preoperative design, and the average operative time of the guides was (29.2±9.8) minutes without complications such as perforation of the bone cortex. Conclusions: The use of sequential sectioning guides to assist in the extraction of mandibular impacted third molars was initially validated to accurately replicate the preoperative sectioning design, and is expected to provide a digital solution to improve surgical precision and ensure safety. Further studies with larger sample sizes are needed to evaluate its accuracy and safety.

4.
Chinese Journal of Stomatology ; (12): 519-526, 2023.
Artículo en Chino | WPRIM | ID: wpr-986104

RESUMEN

In light of the increasing digitalization of dentistry, the automatic determination of three-dimensional (3D) craniomaxillofacial features has become a development trend. 3D craniomaxillofacial landmarks and symmetry reference plane determination algorithm based on point clouds has attracted a lot of attention, for point clouds are the basis for virtual surgery design and facial asymmetry analysis, which play a key role in craniomaxillofacial surgery and orthodontic treatment design. Based on the studies of our team and national and international literatures, this article presented the deep geometry learning algorithm to determine landmarks and symmetry reference plane based on 3D craniomaxillofacial point clouds. In order to provide reference for future clinical application, we describe the development and latest research in this field, and analyze and discuss the advantages and limitations of various methods.


Asunto(s)
Humanos , Imagenología Tridimensional/métodos , Asimetría Facial , Algoritmos
5.
Chinese Journal of Stomatology ; (12): 554-560, 2023.
Artículo en Chino | WPRIM | ID: wpr-986110

RESUMEN

Objective: To explore an automatic landmarking method for anatomical landmarks in the three-dimensional (3D) data of the maxillary complex and preliminarily evaluate its reproducibility and accuracy. Methods: From June 2021 to December 2022, spiral CT data of 31 patients with relatively normal craniofacial morphology were selected from those who visited the Department of Oral and Maxillofacial Surgery, Peking University School and Hospital of Stomatology. The sample included 15 males and 16 females, with the age of (33.3±8.3) years. The maxillary complex was reconstructed in 3D using Mimics software, and the resulting 3D data of the maxillary complex was mesh-refined using Geomagic software. Two attending physicians and one associate chief physician manually landmarked the 31 maxillary complex datasets, determining 24 anatomical landmarks. The average values of the three expert landmarking results were used as the expert-defined landmarks. One case that conformed to the average 3D morphological characteristics of healthy individuals' craniofacial bones was selected as the template data, while the remaining 30 cases were used as target data. The open-source MeshMonk program (a non-rigid registration algorithm) was used to perform an initial alignment of the template and target data based on 4 landmarks (nasion, left and right zygomatic arch prominence, and anterior nasal spine). The template data was then deformed to the shape of the target data using a non-rigid registration algorithm, resulting in the deformed template data. Based on the unchanged index property of homonymous landmarks before and after deformation of the template data, the coordinates of each landmark in the deformed template data were automatically retrieved as the automatic landmarking coordinates of the homonymous landmarks in the target data, thus completing the automatic landmarking process. The automatic landmarking process for the 30 target data was repeated three times. The root-mean-square distance (RMSD) of the dense corresponding point pairs (approximately 25 000 pairs) between the deformed template data and the target data was calculated as the deformation error of the non-rigid registration algorithm, and the intra-class correlation coefficient (ICC) of the deformation error in the three repetitions was analyzed. The linear distances between the automatic landmarking results and the expert-defined landmarks for the 24 anatomical landmarks were calculated as the automatic landmarking errors, and the ICC values of the 3D coordinates in the three automatic landmarking repetitions were analyzed. Results: The average three-dimensional deviation (RMSD) between the deformed template data and the corresponding target data for the 30 cases was (0.70±0.09) mm, with an ICC value of 1.00 for the deformation error in the three repetitions of the non-rigid registration algorithm. The average automatic landmarking error for the 24 anatomical landmarks was (1.86±0.30) mm, with the smallest error at the anterior nasal spine (0.65±0.24) mm and the largest error at the left oribital (3.27±2.28) mm. The ICC values for the 3D coordinates in the three automatic landmarking repetitions were all 1.00. Conclusions: This study established an automatic landmarking method for three-dimensional data of the maxillary complex based on a non-rigid registration algorithm. The accuracy and repeatability of this method for landmarking normal maxillary complex 3D data were relatively good.


Asunto(s)
Masculino , Femenino , Humanos , Adulto , Imagenología Tridimensional/métodos , Reproducibilidad de los Resultados , Algoritmos , Programas Informáticos , Tomografía Computarizada Espiral , Puntos Anatómicos de Referencia/anatomía & histología
6.
Beijing Da Xue Xue Bao ; (6): 343-350, 2023.
Artículo en Chino | WPRIM | ID: wpr-986859

RESUMEN

OBJECTIVE@#To quantitatively evaluate the trueness of five chairside three-dimensional facial scanning techniques, and to provide reference for the application of oral clinical diagnosis and treatment.@*METHODS@#The three-dimensional facial data of the subjects were collected by the traditional professional three-dimensional facial scanner Face Scan, which was used as the reference data of this study. Four kinds of portable three-dimensional facial scanners (including Space Spider, LEO, EVA and DS-FScan) and iPhone Ⅹ mobile phone (Bellus3D facial scanning APP) were used to collect three-dimensional facial data from the subjects. In Geomagic Studio 2013 software, through data registration, deviation analysis and other functions, the overall three-dimensional deviation and facial partition three-dimensional deviation of the above five chairside three-dimensional facial scanning technologies were calculated, and their trueness performance evaluated. Scanning time was recorded during the scanning process, and the subject's comfort was scored by visual analogue scale(VAS). The scanning efficiency and patient acceptance of the five three-dimensional facial scanning techniques were evaluated.@*RESULTS@#DS-FScan had the smallest mean overall and mean partition three-dimensional deviation between the test data and the reference data, which were 0.334 mm and 0.329 mm, respectively. The iPhone Ⅹ mobile phone had the largest mean overall and mean partition three-dimensional deviation between the test data and the reference data, which were 0.483 mm and 0.497 mm, respectively. The detailed features of the three-dimensional facial data obtained by Space Spider were the best. The iPhone Ⅹ mobile phone had the highest scanning efficiency and the highest acceptance by the subject. The average scanning time of the iPhone Ⅹ mobile phone was 14 s, and the VAS score of the subjects' scanning comfort was 9 points.@*CONCLUSION@#Among the five chairside three-dimensional face scanning technologies, the trueness of the scan data of the four portable devices had no significant difference, and they were all better than the iPhone Ⅹ mobile phone scan. The subject with the iPhone Ⅹ scanning technology had the best expe-rience.


Asunto(s)
Imagenología Tridimensional , Programas Informáticos , Modelos Dentales
7.
Artículo en Inglés | WPRIM | ID: wpr-966994

RESUMEN

Purpose@#To investigate the effect of detrusor overactivity (DO) on the urethral expression of caveolin (CAV)-1, -2, and -3 of urethra in an animal model of cyclophosphamide (CYP)-induced cystitis rat. @*Methods@#Female Sprague-Dawley rats were divided into the control group (n=20) and the cystitis group (n=20). Cystitis was induced by intraperitoneal injection of CYP (200 mg/kg). An urodynamic study was done 3 days after the CYP injection to measure functional change of the urinary bladder and urethra. Cellular localization and expression of CAV-1, -2, and -3 in the rat urethra were determined by immunohistochemistry (IHC) and Western blot. @*Results@#Urodynamic experiments demonstrated a decreased contraction interval in the cystitis group compared to the control (3.9±1.0 minutes vs. 6.6±1.2 minutes, P<0.05). Conversely, contraction pressure increased significantly in the cystitis group compared to the control (22.4±0.7 mmHg vs. 11.5±0.4 mmHg, P<0.05). The urethral pressure was decreased in the cystitis group compared to the control (4.05 ±2.5 mmHg vs. 5.8 ±2.8 mmHg, P <0.05). The IHC and Western blot data showed that CAV-1, -2, and -3 expression decreased significantly in the cystitis group compared control group (P<0.05). @*Conclusions@#The decreased urethral CAV-1, -2, and -3 in the DO rats suggests that CAVs might be related with the functional change of urethra in association with DO of urinay bladder.

8.
Zhonghua zhong liu za zhi ; (12): 291-296, 2022.
Artículo en Chino | WPRIM | ID: wpr-935213

RESUMEN

Objective: To analyze the clinical efficacy of fertility-preserving therapy in patients with atypical endometrial hyperplasia (AEH) and early endometrial carcinoma (EC). Methods: The general condition, pathological type, treatment plan, tumor outcomes and pregnancy outcomes of 110 patients with AEH and EC treated with fertility-preserving therapy in Peking University People's Hospital from December 2005 to September 2019 were retrospectively analyzed. Kaplan-Meier and Log rank tests were used for survival analysis. Results: The response rate of 110 cases of AEH (62 cases) and EC (48 cases) was 94.5% (104/110) after fertility-preserving therapy. There were 93 cases (84.5%) achieved complete response and 11 cases (10.0%) achieved partial response, and the recurrence rate was 29.0% (27/93). The complete response rates of AEH and EC were 90.3% (56/62) and 77.1% (37/48), respectively, without significant difference (P=0.057). The recurrence rates of EC were significantly higher than that of AEH (40.5% vs 21.4%; P=0.022). Forty-one patients with complete response had pregnancy intention, the pregnancy rate was 70.7% (29/41), and the live birth rate was 56.1% (23/41). The live birth rate of AEH was 68.2% (15/22) and that of EC was 42.1% (8/19), the difference was statistically significant (P=0.032). The pathological type was related with the recurrence (P=0.044). Conclusions: Patients with AEH and EC can obtain high complete response rate and pregnancy rate after fertility-preserving therapy. The recurrence rate of EC is higher than that of AEH, while the live birth rate of AEH is higher than that of EC.


Asunto(s)
Femenino , Humanos , Embarazo , Hiperplasia Endometrial/cirugía , Neoplasias Endometriales/cirugía , Fertilidad , Preservación de la Fertilidad , Estudios Retrospectivos
9.
Chinese Journal of Stomatology ; (12): 242-250, 2022.
Artículo en Chino | WPRIM | ID: wpr-935857

RESUMEN

Objectives: To study the design of nonmetallic crowns for deciduous molars by means of computer aided design and to analyze the key parameters of the nonmetallic crowns of deciduous molars using finite element method. Methods: The three-dimensional model of a mandibular second primary molar was constructed by using a micro-CT system. The thickness of the crown was limited to 0.5 mm and four different crown shapes (chamfer+anatomic, chamfer+non-anatomic, knife edge+anatomic and knife edge+non-anatomic) were designed. Then, the crown shape was limited as chamfer+non-anatomic and five different thicknesses of the crown (0.50, 0.75, 1.00, 1.25, 1.50 mm) were designed, and three different materials, including polyetherketoneketone (PEKK), polymethylmethacrylate (PMMA) resin and resin-infiltrated ceramic, were applied to make the crown. Stress distribution and fatigue of each component of the model under vertical and oblique loadings were analyzed by using finite element method. Non-axial retention analysis was performed on chamfer+non-anatomic crowns, made of PMMA resin, with thicknesses of 0.50, 0.75, 1.00, 1.25 and 1.50 mm. Results: Among the four crown shape designs, the chamfer+non-anatomic type crown showed the lowest von Mises stress and the highest safety factor. By comparing three different materials, the resin-infiltrated ceramic group showed obvious stress concentration on the buccal edge of the crown and the PEKK group showed stress concentration in the adhesive layer. Results of non-axial retention analysis showed that the torques required by the crowns with five thicknesses at the same rotation angle were as follows: 4 856.1, 4 038.1, 3 497.3, 3 256.3 and 3 074.3 N⋅m, respectively. The comparison of areas of the adhesives fracture among groups were as follows: 0.5 mm group < 0.75 mm group < 1.00 mm group < 1.25 mm group < 1.50 mm group. Conclusions: In the design of nonmetallic crowns for primary molars, the edge of the crown should be designed as chamfer, the shape of the inner crown should be non-anatomical and the minimum preparation amount of the occlusal surface should be 1.00 mm. Among the three materials, PMMA resin, of which elastic modulus is similar to the dentin and the dental adhesive, might be the most suitable material for the crowns of primary molars.


Asunto(s)
Cerámica , Coronas , Análisis del Estrés Dental/métodos , Análisis de Elementos Finitos , Diente Molar
10.
Chinese Journal of Stomatology ; (12): 358-365, 2022.
Artículo en Chino | WPRIM | ID: wpr-935875

RESUMEN

Objective: To explore the establishment of an efficient and automatic method to determine anatomical landmarks in three-dimensional (3D) facial data, and to evaluate the effectiveness of this method in determining landmarks. Methods: A total of 30 male patients with tooth defect or dentition defect (with good facial symmetry) who visited the Department of Prosthodontics, Peking University School and Hospital of Stomatology from June to August 2021 were selected, and these participants' age was between 18-45 years. 3D facial data of patients was collected and the size normalization and overlap alignment were performed based on the Procrustes analysis algorithm. A 3D face average model was built in Geomagic Studio 2013 software, and a 3D face template was built through parametric processing. MeshLab 2020 software was used to determine the serial number information of 32 facial anatomical landmarks (10 midline landmarks and 22 bilateral landmarks). Five male patients with no mandibular deviation and 5 with mild mandibular deviation were selected from the Department of Orthodontics or Oral and Maxillofacial Surgery, Peking University School and Hospital of Stomatology from June to August 2021. 3D facial data of patients was collected as test data. Based on the 3D face template and the serial number information of the facial anatomical landmarks, the coordinates of 32 facial anatomical landmarks on the test data were automatically determined with the help of the MeshMonk non-rigid registration algorithm program, as the data for the template method to determine the landmarks. The positions of 32 facial anatomical landmarks on the test data were manually determined by the same attending physician, and the coordinates of the landmarks were recorded as the data for determining landmarks by the expert method. Calculated the distance value of the coordinates of facial anatomical landmarks between the template method and the expert method, as the landmark localization error, and evaluated the effect of the template method in determining the landmarks. Results: For 5 patients with no mandibular deviation, the landmark localization error of all facial anatomical landmarks by template method was (1.65±1.19) mm, the landmark localization error of the midline facial anatomical landmarks was (1.19±0.45) mm, the landmark localization error of bilateral facial anatomical landmarks was (1.85±1.33) mm. For 5 patients with mild mandibular deviation, the landmark localization error of all facial anatomical landmarks by template method was (2.55±2.22) mm, the landmark localization error of the midline facial anatomical landmarks was (1.85±1.13) mm, the landmark localization error of bilateral facial anatomical landmarks was (2.87±2.45) mm. Conclusions: The automatic determination method of facial anatomical landmarks proposed in this study has certain feasibility, and the determination effect of midline facial anatomical landmarks is better than that of bilateral facial anatomical landmarks. The effect of determining facial anatomical landmarks in patients without mandibular deviation is better than that in patients with mild mandibular deviation.


Asunto(s)
Adolescente , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven , Algoritmos , Puntos Anatómicos de Referencia , Cefalometría/métodos , Cara/anatomía & histología , Imagenología Tridimensional/métodos , Maloclusión , Ortodoncia , Programas Informáticos
11.
Beijing Da Xue Xue Bao ; (6): 134-139, 2022.
Artículo en Chino | WPRIM | ID: wpr-936124

RESUMEN

OBJECTIVE@#To establish a deep learning algorithm that can accurately determine three-dimensional facial anatomical landmarks, multi-view stacked hourglass convolutional neural networks (MSH-CNN) and to construct three-dimensional facial midsagittal plane automatically based on MSH-CNN and weighted Procrustes analysis algorithm.@*METHODS@#One hundred subjects with no obvious facial deformity were collected in our oral clinic. Three-dimensional facial data were scanned by three-dimensional facial scanner. Experts annotated twenty-one facial landmarks and midsagittal plane of each data. Eighty three-dimensional facial data were used as training set, to train the MSH-CNN in this study. The overview of MSH-CNN network architecture contained multi-view rendering and training the MSH-CNN network. The three-dimensional facial data were rendered from ninety-six views that were fed to MSH-CNN and the output was one heatmap per landmark. The result of the twenty-one landmarks was accurately placed on the three-dimensional facial data after a three-dimensional view ray voting process. The remaining twenty three-dimensional facial data were used as test set. The trained MSH-CNN automatically determined twenty-one three-dimensional facial anatomical landmarks of each case of data, and calculated the distance between each MSH-CNN landmark and the expert landmark, which was defined as position error. The midsagittal plane of the twenty subjects' could be automatically constructed, using the MSH-CNN and Procrustes analysis algorithm. To evaluate the effect of midsagittal plane by automatic method, the angle between the midsagittal plane constructed by the automatic method and the expert annotated plane was calculated, which was defined as angle error.@*RESULTS@#For twenty subjects with no obvious facial deformity, the average angle error of the midsagittal plane constructed by MSH-CNN and weighted Procrustes analysis algorithm was 0.73°±0.50°, in which the average position error of the twenty-one facial landmarks automatically determined by MSH-CNN was (1.13±0.24) mm, the maximum position error of the orbital area was (1.31±0.54) mm, and the minimum position error of the nasal area was (0.79±0.36) mm.@*CONCLUSION@#This research combines deep learning algorithms and Procrustes analysis algorithms to realize the fully automated construction of the three-dimensional midsagittal plane, which initially achieves the construction effect of clinical experts. The obtained results constituted the basis for the independent intellectual property software development.


Asunto(s)
Humanos , Algoritmos , Aprendizaje Profundo , Cara , Redes Neurales de la Computación , Programas Informáticos
12.
Beijing Da Xue Xue Bao ; (6): 146-152, 2022.
Artículo en Chino | WPRIM | ID: wpr-936126

RESUMEN

OBJECTIVE@#To evaluate the accuracy of trephine bur drilling at different depths guided by dynamic navigation system in 3D printing in vitro model.@*METHODS@#A model at the depth of 5 mm, 10 mm, and 15 mm from the outer surface of which hemispherical cavities was reserved and the 3D printing technology was used to make the standardized model with Veroclear resin. The cone beam CT (CBCT) was taken and the data were imported into the dynamic navigation software (DCARER, China) to establish navigation path programming. Under the guidance of dynamic navigation, a trephine bur with a diameter of 4.5 mm was used to complete the access operation. At each depth, 10 approaches were completed. The postoperative model CBCT was taken. The approach trajectory under navigation was reconstructed and compared with the designed path. The two-dimensional distance deviation, depth deviation, three-dimensional distance deviation, and angle deviation between the actually prepared path and the designed path were calculated.@*RESULTS@#At the depth of 5 mm, the two-dimensional distance deviation between the end position of the prepared path and the designed path was (0.37±0.06) mm, the depth deviation was (0.06±0.05) mm, the three-dimensional distance deviation was (0.38±0.07) mm, and the angle deviation was 2.46°±0.54°; At the depth of 10 mm, the four deviations between the end position of prepared path and the designed path were (0.44±0.05) mm, (0.16±0.06) mm, (0.47±0.05) mm, and 2.45°±1.21°, respectively; At the depth of 15 mm, the four deviations were (0.52±0.14) mm, (0.16±0.07) mm, (0.55±0.15) mm, and 3.25°±1.22°, respectively. With the increase of entry depth, the three-dimensional and depth accuracy of dynamic navigation system decreased (P < 0.01), and the positioning angle deviation had no relation with the entry depth (P>0.01).@*CONCLUSION@#Dynamic navigation technology can achieve high positioning accuracy in the depth range of 15 mm, but its deviation increases with the increase of entry depth.


Asunto(s)
China , Tomografía Computarizada de Haz Cónico , Impresión Tridimensional , Cirugía Asistida por Computador
13.
Beijing Da Xue Xue Bao ; (6): 193-199, 2022.
Artículo en Chino | WPRIM | ID: wpr-936134

RESUMEN

OBJECTIVE@#To automatically construct lips symmetry reference plane (SRP) based on posed smile, and to evaluate its advantages over conventional digital aesthetic design.@*METHODS@#Eighteen subjects' three-dimensional facial and dentition data were gathered in this study. The lips SRP of experimental groups were used with the standard weighted Procrustes analysis (WPA) algorithm and iterative closest point (ICP), respectively. A reference plane defined by experts based on regional ICP algorithm, served as the truth plane. The angle error values between the lips SRP of WPA algorithm in the experimental groups and the truth plane were evaluated in this study, and the lips SRP of ICP algorithm of the experimental groups was calculated in the same way. The lips SRP based on posed smile as a reference for aesthetic design and evaluate preliminary clinical application.@*RESULTS@#The average angle error between the lips SRP of WPA algorithm and the truth plane was 1.78°±1.24°, which was smaller than that between the lips SRP of ICP and the truth plane 7.41°±4.31°. There were significant differences in the angle errors among the groups (P < 0.05). In the aesthetic design of anterior teeth, automatically constructing the lips SRP of WPA algorithm based on posed smile and the original symmetry plane by re-ference compared with the prosthetic design, the subjects' scores on the lips SRP of WPA algorithm based on posed smile (8.48±0.57) were higher than those on the original symmetry plane (5.20±1.31).@*CONCLUSION@#Automatically constructing the lips SRP of WPA algorithm based on posed smile was more accurate than ICP algorithm, which was consistent with the truth plane. Moreover, it can provide an important reference for oral aesthetic diagnosis and aesthetic analysis of the restoration effect. In the aesthetic design of anterior teeth, automatically constructing the lips SRP of WPA algorithm based on posed smile can improve the patients' satisfaction in esthetic rehabilitation.


Asunto(s)
Humanos , Estética Dental , Labio , Sonrisa , Diente , Flujo de Trabajo
14.
Beijing Da Xue Xue Bao ; (6): 327-334, 2022.
Artículo en Chino | WPRIM | ID: wpr-936155

RESUMEN

OBJECTIVE@#To explore the construction process of the digital reference crown models, and to initially establish the digital reference crown models of the primary teeth to lay the foundation for the establishment of the standardized crown models and the future related applications of computer-aided design/computer-aided manufacture (CAD/CAM) technology to pediatric dentistry.@*METHODS@#This study randomly selected children who were caries free, aged from 4 to 5 years in several kindergartens of Haidian District of Beijing.Plaster dental models were made for the children after taking complete impressions.The digital dental models were reconstructed by using the three-dimensional (3D) dental model scanner.And then, Geomagic Studio, a 3D reverse engineering software, was employed to extract the single dental crown data, the mesiodistal and buccolingual diameters and the height of the crowns were measured.The object was reduced or enlarged by a numerical factor, and then the size of each dental crown was standardized.A total of 3-5 points features on the crown were created, and all the objects were aligned through the functions of feature-based alignment.Finally, through average-based object creation and smoothing, the digital models of reference crowns of the primary teeth were established.@*RESULTS@#A total of 40 plaster dental models from 16 boys and 26 girls were selected out for our further study.The digital dental models were reconstructed, and the mesiodistal and buccolingual diameters and the height of the crowns were measured by using reverse engineering technology.Comparing the results of using mesiodistal diameter, buccolingual diameter and height as the standards, we chose the mesiodistal diameters of crowns to do the standardization, and successfully established the digital reference models of 20 primary teeth crowns with detailed surface characteristics.@*CONCLUSION@#In this study, the digital reference crown models of the primary teeth were established by reverse engineering technology, providing reference value for the standardized crown models and application for clinical practice, scientific research and teaching.Furthermore, this study also contributes to the extensive application of CAD/CAM technology in pediatric dentistry and the development of CAD/CAM dental systems with independent intellectual property rights.


Asunto(s)
Niño , Femenino , Humanos , Masculino , Diseño Asistido por Computadora , Coronas , Diseño de Prótesis Dental , Programas Informáticos , Corona del Diente , Diente Primario
15.
Zhongguo zhenjiu ; (12): 552-554, 2022.
Artículo en Chino | WPRIM | ID: wpr-927422

RESUMEN

To summarize YU Tian-yuan's experience of applying Danzhong (CV 17) for mental illness in acupuncture and tuina. YU Tian-yuan uses Danzhong (CV 17) alone or in combination with other acupoints to treat mental illnesses such as insomnia, palpitation and chest distress. Professor YU emphasizes 4 tips when treating diseases, nourishing the heart to tranquilize by light stimulation; regulating spirit by combined stimulation; leaving the acupoints and holding on the meridian for a wide range of stimulation; using rubbing and pushing manipulation in several directions for regulating qi to soothe the chest. And in clinical practice, formed a unique therapy to treat mental illness.


Asunto(s)
Humanos , Acupuntura , Puntos de Acupuntura , Terapia por Acupuntura , Trastornos Mentales/terapia , Meridianos
16.
Artículo en Chino | WPRIM | ID: wpr-911361

RESUMEN

Objective:To investigate the possible role of long non-coding RNA (LncRNA) 00602 in promoting browning in adipocytes induced by adenovirus type 36 (Ad36).Methods:According to Ad36 infection, adipose tissue samples of obese patients were divided into Ad36-negative group and Ad36-infected group. Realtime fluorescent quantitative PCR (qRT-PCR) was used to detect the changes in the expression of LncRNA00602 mRNA in omental adipose tissue of the two groups, and analyze the differences between the two groups. The correlation between waist-to-hip ratio, systolic blood pressure, diastolic blood pressure, fasting blood glucose, triacylglyceride and other indicators of the patients in the group with LncRNA00602 mRNA expression were analyzed. HE staining was used to detect the size of adipocytes in the omental adipose tissue of the Ad36 negative group and the Ad36 infection group. qRT-PCR and Western blotting were used to detect the mRNA and protein expression levels of uncoupling protein 1 (UCP1) and PR domain containing 16 (PRDM16) in omental adipose tissue of two groups of patients. Human adipose-derived stem cells (hADSC) were isolated and cultured, using Ad36 to induce differentiation, and divided into control group and LncRNA00602 knockdown group. On 0, 2, and 4 days after LncRNA00602 knockdown, fluoroboron dipyrrole (BODIPY) and mitochondrial red fluorescence (Mito-Tracker Red) were used to stain intracellular lipid droplets and mitochondria. At the same time, qRT-PCR and Western blotting were used to detect changes in the expression of UCP1 and PRDM16.Results:The expression of LncRNA00602 gene in the Ad36 infection group was higher than that in the Ad36 negative group (all P<0.05). The expression of LncRNA00602 in the Ad36 negative group was not significantly different from the above clinical indicators, while the expression of LncRNA00602 was negatively correlated with serum fasting blood glucose and triacylglyceride ( r=-0.522, -0.486, P<0.05) in the Ad36 infection group; HE staining showed that the average adipocyte area of the Ad36 infection group was smaller than that of the Ad36 negative group. At the same time, UCP1 and PRDM16 gene expression were higher than the negative group (all P<0.05). At the cellular level, on the 2nd and 4th days after knockdown of LncRNA00602, the lipid droplet area of adipocytes in the LncRNA00602 knockdown group was larger than that of the control group, the number of mitochondria decreased compared with the control group, and difference was statistically significant ( P<0.05 or P<0.01); Compared with the control group, there was significantly lower expression of the browning marker genes UCP1, PRDM16, and protein in the adipocytes in the LncRNA00602 knockdown group (all P<0.05). Conclusion:In Ad36-induced adipocyte differentiation, LncRNA00602 may positively regulate the expression of UCP1, PRDM16 and lipid droplet metabolism, and promote the browning of adipocytes.

17.
Chinese Pharmacological Bulletin ; (12): 1593-1599, 2021.
Artículo en Chino | WPRIM | ID: wpr-1014511

RESUMEN

Aim To study the regulatory effect of FOXA2 on liver function and blood lipid levels in mice with intrahepatic cholestasis and hyperlipidemia. Methods The model was constructed by feeding high cholesterol/cholic acid (CAD), and the FOXA2 plasmid was injected into the liver of mice by tail vein hypertension, so that the hepatocytes overexpressed F0XA2. The automatic blood biochemical analyzer was uses to detect the blood biochemical indicators of the serum, the colorimetric method to detect the cholesterol level in liver, and ELISA method to detect the liver bile acid level. Western blot was used to determine the expression of liver FOXA2, and RT-PCR to assess the mRNA expression of genes related to bile acid metabolism. H&E and oil red staining were employed to observe liver pathology. Results With the extension feeding time of the CAD, the weight of the mice continued to decrease (P < 0.01), the gallbladder increased significantly (P < 0.01), and the level of transaminase increased, and serum cholesterol and low-density lipoprotein cholesterol (P < 0.01) increased significantly. Liver tissue structure was damaged, liver cholesterol was elevated (P <0.01), bile acid level increased (P < 0.01), and lipid accumulation was serious. Overexpression of FOXA2 could significantly improve liver function and dyslipidemia in CAD-fed mice by regulating liver bile acid metabolism genes, and reduce liver bile acid levels (P < 0.01) and liver lipid accumulation. Conclusions FOXA2 improves liver function and blood lipid levels in mice with intrahepatic cholestasis and hyperlipidemia.

18.
Chinese Pharmaceutical Journal ; (24): 951-954, 2020.
Artículo en Chino | WPRIM | ID: wpr-857691

RESUMEN

OBJECTIVE: To explore the application effect of quality control circle management in improving the qualified rate of anesthetic drugs prescription in hospital. METHODS: The quality control circle was established to explore the causes of the unqualified anesthetic drugs prescription in our hospital by using the 80/20 rule and fish-bone diagram. The measures to improve the prescription pass rate were determined, and the changes of the prescription pass rate before and after QCC management were compared through the implementation and review of the measures. RESULTS: Using the management of quality control circle, the prescription quality of inpatient anesthetic drugs was significantly improved in our hospital in 2018 and the qualified rate increased from 70.07% in 2017 to 2018 97.78% above target value of 6.69%. After continuous quality control circle management, the qualified rate of prescription increased to 99.33% in the first three quarters of 2019. CONCLUSION: The development of QCC can effectively improve the qualified rate of anesthetic drugs prescription in hospital, not only standardizing the use of anesthetic drugs, promoting drug safety of patients, but also improving the comprehensive quality of pharmacists and the quality of hospital pharmaceutical care.

19.
Beijing Da Xue Xue Bao ; (6): 107-112, 2020.
Artículo en Chino | WPRIM | ID: wpr-941974

RESUMEN

OBJECTIVE@#To study the visual sensitivity threshold of physician's naked eye to the difference of nasolabial angle in edentulous jaw patients, and to provide a reference value for the study of aesthetic evaluation of soft tissue profile for the difference of nasolabial angle that can be recognized by human eyes.@*METHODS@#Three-dimensional facial images of three edentulous patients with different diagnostic dentures introoral were obtained. Lateral screenshots of each patient's three-dimensional facial image with the same scale were obtained by using reverse engineering software (Geomagic studio 2014).The screenshot of the patient's three-dimensional facial image with suitable lip support (The suitable lip support was confirmed by both patients and prosthodontists who had clinical experience for more than 20 years) was taken as the reference picture, and the remaining pictures were grouped with it respectively. All the pictures were observed in random order by the subjects. Fifteen dentists were asked to judge the difference of nasolabial angle between the two pictures of each group on the computer screen. The difference of nasolabial angle between the two pictures in each group was measured and calculated. The ROC curve was drawn, and the best cut-off value was calculated as the visual sensitivity threshold.@*RESULTS@#The data of the 15 subjects were used to draw ROC curves separately. The maximum and minimum best cut-off values were 5.55 degrees and 3.12 degrees respectively. The ROC curve of the whole 15 subjects was drawn after data aggregation, and the best cut-off value was 5.36 degrees (AUC=0.84>0.5, P=0.000<0.05). When the difference of nasolabial angle was above 5.36 degrees, the subjects could recognize it effectively.@*CONCLUSION@#There is a visual limit in the observation of the nasolabial angle with the naked eye. In this study, a visual sensitivity threshold of 5.36 degrees for the difference of the nasolabial angle was obtained. The difference of nasolabial angle below this value can be regarded as no clinical significance. This result provides a reference value for human eyes to recognize the difference of nasolabial angle in soft tissue profile aesthetic evaluation. It can be applied to the aesthetic evaluation of soft tissue profile and can be used as the error level of related research with nasolabial angle as an index for accuracy evaluation.


Asunto(s)
Humanos , Estética , Cara , Arcada Edéntula , Labio , Nariz , Agudeza Visual
20.
Beijing Da Xue Xue Bao ; (6): 129-137, 2020.
Artículo en Chino | WPRIM | ID: wpr-941978

RESUMEN

OBJECTIVE@#To provide a reference for using intraoral scanners for making clinical diagnostic dentures of edentulous jaws by comparing the accuracy of three intraoral scanners for primary impression and jaw relation record of edentulous jaws.@*METHODS@#This study contained 6 primary impressions of the edentulous patients. Each of the impressions consisted of the maxillary primary impression, the mandibular primary impression and the jaw relation record. For each of them, a dental cast scanner (Dentscan Y500) was used to obtain stereolithography (STL) data as reference scan, and then three intraoral scanners including i500, Trios 3 and CEREC Primescan were used for three times to obtain STL data as experiment groups. In Geomagic Studio 2013 software, trueness was obtained by comparing experiment groups with the reference scan, and the precision was obtained from intragroup comparisons. Registered maxillary data of the intraoral scan with reference scan, the morphological error of jaw relation record was obtained by comparing jaw relation record of the intraoral scan with the reference scan. Registered mandibular data with jaw relation record of intraoral scan and the displacement of the jaw position were evaluated. Independent samples t test and Mann-Whitney U test in the SPSS 20.0 statistical software were used to statistically analyze the trueness, precision and morphological error of jaw relation record of three intraoral scanners. The Bland-Altman diagram was used to evaluate the consistency of the jaw relationship measured by the three intraoral scanners.@*RESULTS@#The trueness of i500, Trios 3 and CEREC Primescan scanners was (182.34±101.21) μm, (145.21±71.73) μm, and (78.34±34.79) μm for maxilla; (106.42±21.63) μm, and 95.08 (63.08) μm, (78.45±42.77) μm for mandible. There was no significant difference in trueness of the three scanners when scanning the maxilla and mandible(P>0.05). The precision of the three scanners was 147.65 (156.30) μm, (147.54±83.33) μm, and 40.30 (32.80) μm for maxilla; (90.96±30.77) μm, (53.73±23.56) μm, and 37.60 (93.93) μm for mandible. The precision of CEREC Primescan scanner was significantly better than that of the other two scanners for maxilla (P<0.05). Trios 3 and CEREC Primescan scanners were significantly better than i500 scanner for mandible (P<0.05). The precision of the i500 and Trios 3 scanners for mandible was superior to maxilla (P<0.05). The upper limit of 95% confidence intervals of trueness and precision of three scanners for both maxilla and mandible were within ±300 μm which was clinically accepted. The morphological error of jaw relation record of the three scanners was (337.68±128.54) μm, (342.89±195.41) μm, and (168.62±88.35) μm. The 95% confidence intervals of i500 and Trios 3 scanners were over 300 μm. CEREC Primescan scanner was significantly superior to i500 scanner(P<0.05).The displacement of the jaw position of the three scanners was (0.83±0.56) mm, (0.80±0.45) mm, and (0.91±0.75) mm for vertical dimension; (0.79±0.58) mm, (0.62±0.18) mm, and (0.53±0.53) mm for anterior and posterior directions; (0.95±0.59) mm, (0.69±0.45) mm, and (0.60±0.22) mm for left and right directions. The displacement of the jaw position of the three scanners in vertical dimension, anterior and posterior directions and the left and right directions were within the 95% consistency limit.@*CONCLUSION@#Three intraoral scanners showed good trueness and precision. The i500 and Trios 3 scanners had more errors in jaw relation record, but they were used as primary jaw relation record. It is suggested that three intraoral scanners can be used for obtaining digital data to make diagnostic dentures and individual trays, reducing possible deforming or crack when sending impressions from clinic to laboratory.


Asunto(s)
Humanos , Diseño Asistido por Computadora , Técnica de Impresión Dental , Imagenología Tridimensional , Arcada Edéntula , Modelos Dentales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA