RESUMEN
There are many multi-original medicinal materials in Chinese Pharmacopoeia, and the mixed use of medicinal materials from different sources is common, which has certain influence on the stability of clinical medication. In this study, pyrosequencing technology was used to screen species-specific single nucleotide polymorphisms (SNP) from commonly used DNA barcode sequences, and a rapid and accurate molecular identification method for original species in mixed medicinal powder of Epimedii Folium was established. Multiple sequence alignment analysis showed that the 176th (C/T) mutation and the 196th (A/G) mutation of ITS, the 123rd (C/G) mutation of matK and the 892nd (A/C) mutation of rbcL could be used as the unique SNPs of E. sagittatum, E. koreanum, E. brevicornu and E. pubescens, respectively. In this study, the applicability of pyrosequencing and Sanger sequencing methods in the sequencing of mixture samples was investigated from the perspective of sensitivity and stability. Pyrosequencing method has higher detection sensitivity than Sanger sequencing method for low content samples in the mixed samples. Stability analysis showed that pyrosequencing technology could still obtain effective sequencing results for the amplified products of template DNA after 45 min of 95 ℃ high temperature water bath, while the critical point of Sanger sequencing method was 30 min. In this study, a new identification technology of Epimedii Folium mixed powder primordial species based on pyrosequencing and specific SNP was developed, which can quickly and accurately identify the mixed use of Epimedii Folium with high sensitivity and stability, and can also support the identification of different primordial species and mixed powder primordial herbs, which is conducive to ensuring the consistency and stability of clinical medication.
RESUMEN
Objective: To investigate the effect of bare-metal stent related technique on distal aortic dissection involving abdominal visceral segment. Methods: A retrospective analysis was performed on clinical data of 33 patients with distal aortic dissection involved abdominal visceral segment, who hospitalized in the Vascular Surgery Department of Shanghai Changhai Hospital from July 2012 to September 2019. The effect of the treatment was evaluated according to the clinical and preoperative, intraoperative and follow-up imaging data derived from (aorta computed tomography angiography (CTA) and digital subtraction angiography (DSA)) as well as the changes of the maximal diameter of the aorta and the thrombosis of the false lumen of the dissection. The criteria were as follows: the maximum diameter change of aortic dissection<5 mm was defined as stable; the maximum diameter decrease of aortic dissection≥5 mm was defined as effective reduction; the maximum diameter increase of aortic dissection≥5 mm was defined as expansion; the definition of diameter change of false lumen was the same as above. The hospital complications, clinical symptoms and survival were recorded. Results: There were 28 male patients in this cohort, the mean age was (57.6±4.9) years old. Twenty-one patients were treated with bare-metal stent and coils technique, of which 8 patients were jointly treated with stent grafts. Twelve patients were treated with multi-layer bare-metal stent technique, of which 4 patients were jointly treated with stent grafts. Intraoperative DSA image results showed that the visceral arteries were patent during the treatment, and the blood flow velocity of the false lumen was reduced in all 33 patients. There were no adverse events such as distal outflow tract embolism and coil displacement during the operation. During the period of hospitalization, one patient developed intimal rupture of subrenal abdominal aortic dissection on the fourth day after operation and emergency endovascular graft exclusion was performed for abdominal aortic dissection, and the patient recovered well from the emergency operation. The follow-up time was (16.7±14.0) months. One patient died 1 year after surgery due to non-disease-related factors. Follow-up CTA imaging results showed that the maximum diameter of the aorta in abdominal visceral segment tended to be smaller ((39.1±13.4) mm vs. (41.3±11.9) mm, P=0.469), and the maximum diameter of the false lumen was significantly reduced ((16.2±12.9) mm vs. (23.5±10.7) mm, P=0.014). The maximum diameter of the aortic dissection was reduced in 12 cases, stable in 19 cases, expanded in 2 cases. The maximum diameter of the false lumen was effectively reduced in 22 cases, stable in 10 cases, and expanded in 1 case. Four patients developed small endoleak in the false lumen, one of them was nearby the renal artery stent, and the remaining patients experienced complete thrombosis of the false lumen. Conclusions: Endovascular treatment of distal aortic dissection involving abdominal visceral segment with bare-metal stents related technique could promote the shrink and the thrombosis of the false lumen, and slow down the blood flow from the tear into the false lumen in the setting of patency of visceral arteries.
Asunto(s)
Humanos , Masculino , Persona de Mediana Edad , Disección Aórtica/cirugía , Aneurisma de la Aorta Torácica/cirugía , Aortografía , Implantación de Prótesis Vascular , China , Procedimientos Endovasculares , Estudios Retrospectivos , Stents , Resultado del TratamientoRESUMEN
<p><b>OBJECTIVES</b>To analyze the long-term results of fibrin glue embolization to eliminate type I endoleaks after endovascular aneurysm repair (EVAR), and to assess the feasibility and durability of this technique.</p><p><b>METHODS</b>From August 2002 to June 2010, among the 953 EVAR patients, 51 (5.4%) patients underwent intraoperative transcatheter fibrin glue sac embolization to resolve type I endoleak persisting after initial intraoperative maneuvers to close the leak or in necks too short or angulated for cuff placement. Computed tomographic angiography was performed to assess the outcome after 3, 6, and 12 months and annually thereafter. A retrospective study was conducted, and characteristics of the patients, intra-sac pressure, hospital course, and long-term outcomes were recorded.</p><p><b>RESULTS</b>Among the 51 patients, 19 (37.3%) patients had proximal necks long < 10 mm, and 6 (11.8%) patients had proximal neck angulation > 60°; 22 patients (3 additional iliac extension, 14 cuffs, and/or 8 stents) had been placed with additional devices. After fibrin glue injection, 50 (98.0%) of the 51 endoleaks were successfully resolved, and intra-sac pressure (including systolic, diastolic, mean pressures, pulse pressure, and the mean pressure indexes) decreased significantly in these cases. The patient who failed embolotherapy was converted to open surgery (2.0%); he died 2 months later from multiorgan failure. And other two (4.8%) patients died in the peri-operative period from myocardial infarction. The median of follow-up of 48 patients was 45 months (range 4 - 106 months). The mean maximal aneurysm diameter fell from the baseline (61.5 ± 15.2) mm to (48.8 ± 10.1) mm (P = 0.000). Three (6.2%) patients died in the follow-up duration (1 aneurysm-related, died of renal failure which was caused by the compromised renal artery). Cumulative survival was 97.9% at 1 year, 94.5% at 3 years, and 90.8% at 4 years. No recurrent type I endoleak or glue-related complications were observed in follow-up.</p><p><b>CONCLUSIONS</b>Fibrin glue embolization to eliminate type I endoleak after EVAR has yielded promising results in this study, and it can effectively and durable resolve the type I endoleaks. Balloon occlusion of the inflow of the endoleak must be done during glue injection, to enhance the safety and facilitate formation of a structured fibrin clot.</p>
Asunto(s)
Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Aneurisma de la Aorta Abdominal , Cirugía General , Terapéutica , Implantación de Prótesis Vascular , Embolización Terapéutica , Métodos , Endofuga , Terapéutica , Adhesivo de Tejido de Fibrina , Usos Terapéuticos , Complicaciones Posoperatorias , Terapéutica , Resultado del TratamientoRESUMEN
<p><b>OBJECTIVE</b>To evaluate the effect of the diameter of abdominal aortic aneurysm (AAA) on endovascular exclusion (EVE) and its results.</p><p><b>METHODS</b>From March 1997 to June 2007, 429 AAA patients were treated with endovascular stent-graft exclusion. According to the maximal diameter of abdominal aortic aneurysm, the patients were divided into two groups: group A (diameter < 55 mm, n = 274) and group B (diameter > or = 55 mm, n = 155). The diameter of AAA, involvement of iliac artery, length, diameter and distortion of aneurismal neck in the two groups were recorded and compared retrospectively.</p><p><b>RESULTS</b>Patients in group B were significantly older than group A (73.7 vs 71.1 years, P < 0.05). More patients in group B was complicated with coronary artery disease than those in group A (P < 0.05). The mean diameter of AAA in group A was (46.6 +/- 6.8) mm, and (66.8 +/- 11.2) mm in group B (P < 0.05). Proximal aneurysmal necks were shorter, wider and more tortuous in group B than those in group A (P < 0.05). Extraperitoneal approach, embolism of inner iliac artery and reconstruction of another inner iliac artery and stretch technique were more applied in group B. There were more endoleak during operation in group B and more stent-grafts were used. There was significant difference in morbidity rate between the two groups, while no statistic difference in mortality. And in group B, there were a high rate of endoleak and secondary intervention post operation.</p><p><b>CONCLUSIONS</b>The diameter of AAA affects EVE and its results. In small aneurysms, EVE carries better outcome than in big aneurysms.</p>
Asunto(s)
Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Aneurisma de la Aorta Abdominal , Patología , Cirugía General , Implantación de Prótesis Vascular , Métodos , Estudios de Seguimiento , Pronóstico , Estudios Retrospectivos , Stents , Resultado del TratamientoRESUMEN
<p><b>OBJECTIVE</b>To evaluate the technical feasibility of juxtarenal abdominal aortic aneurysm (AAA) repair with fenestrated endovascular stent-graft</p><p><b>METHODS</b>A 64-year-old male was diagnosed with juxtarenal AAA with severe coronary artery stenosis, fenestrations was customized according to precise helical CT data to accommodate visceral and renal arteries. Under general anesthesia and dynamic supervision of digital subtraction angiography (DSA), juxtarenal AAA was excluded with the customized fenestrated stent-graft and balloon expandable mini stent-grafts were deployed into bilateral renal arteries respectively.</p><p><b>RESULTS</b>After operation, DSA showed the patency of the super mesenteric artery, bilateral renal arteries and left hypogastric artery, no endoleak was found. The serum creatinine decreased slightly after operation. CT angiography revealed favorable morphology of the stent-graft without tortuosity, migration, disjoint and endoleak 10 days after the operation and patency of super mesenteric artery, bilateral renal arteries and left hypogastric artery.</p><p><b>CONCLUSIONS</b>The placement of customized fenestrated endovascular stent-graft is a feasible option for juxtarenal AAA.</p>