Chinese Journal of Medical Instrumentation ; (6): 20-22, 2002.
Artículo en Chino | WPRIM | ID: wpr-241074

RESUMEN

In this paper, two new concepts of DR (Dose Repulsion) and DG (Dose Gravitation) are presented with their calculation formulas. For the problem of selecting beam arcs in x-knife radiotherapy Planning system, a mathematics model of constrained optimization has been built. Furthermore, we have produced a feasible project of automatic selecting optimized beam arcs plan using SA (Simulated Annealing) arithmetic based on the distribution of the fields of DR and DG in the reduced phase space.


Asunto(s)
Algoritmos , Neoplasias Encefálicas , Radioterapia , Modelos Teóricos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Métodos , Radioterapia Conformacional , Métodos