Japanese Journal of Cardiovascular Surgery ; : 279-283, 2013.
Artículo en Japonés | WPRIM | ID: wpr-374585

RESUMEN

Para-anastomotic aneurysms may have dangerous complications such as rupture and thrombosis, with consequent loss of life. As these complications are associated with high mortality rates, early detection and prompt surgical treatment are important. Repair of para-anastomotic aneurysms may be challenging and the surgical approach should be carefully planned. A 66-year-old man had undergone thoracoabdominal aortic aneurysm repair 18 years previously. The diameter of the distal aortic anastomosis was gradually increasing. We comprehensively discussed the surgical approach preoperatively, including consideration of spinal cord protection. Abdominal aortic graft replacement was performed through a midline abdominal incision, with cross-clamping on the proximal side of the aneurysm, continuous intravenous infusion of naloxone, and segmental aortic clamping with distal aortic perfusion and selective visceral perfusion. The left renal artery was reconstructed, and the inferior mesenteric artery and lumbar arteries were preserved.