Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Korean Journal of Radiology ; : 284-293, 2023.
Artículo en Inglés | WPRIM | ID: wpr-968241

RESUMEN

Objective@#To validate a simplified ordinal scoring method, referred to as modified length-based grading, for assessing coronary artery calcium (CAC) severity on non-electrocardiogram (ECG)-gated chest computed tomography (CT). @*Materials and Methods@#This retrospective study enrolled 120 patients (mean age ± standard deviation [SD], 63.1 ± 14.5 years; male, 64) who underwent both non-ECG-gated chest CT and ECG-gated cardiac CT between January 2011 and December 2021. Six radiologists independently assessed CAC severity on chest CT using two scoring methods (visual assessment and modified length-based grading) and categorized the results as none, mild, moderate, or severe. The CAC category on cardiac CT assessed using the Agatston score was used as the reference standard. Agreement among the six observers for CAC category classification was assessed using Fleiss kappa statistics. Agreement between CAC categories on chest CT obtained using either method and the Agatston score categories on cardiac CT was assessed using Cohen’s kappa. The time taken to evaluate CAC grading was compared between the observers and two grading methods. @*Results@#For differentiation of the four CAC categories, interobserver agreement was moderate for visual assessment (Fleiss kappa, 0.553 [95% confidence interval {CI}: 0.496–0.610]) and good for modified length-based grading (Fleiss kappa, 0.695 [95% CI: 0.636–0.754]). The modified length-based grading demonstrated better agreement with the reference standard categorization with cardiac CT than visual assessment (Cohen’s kappa, 0.565 [95% CI: 0.511–0.619 for visual assessment vs. 0.695 [95% CI: 0.638–0.752] for modified length-based grading). The overall time for evaluating CAC grading was slightly shorter in visual assessment (mean ± SD, 41.8 ± 38.9 s) than in modified length-based grading (43.5 ± 33.2 s) (P < 0.001). @*Conclusion@#The modified length-based grading worked well for evaluating CAC on non-ECG-gated chest CT with better interobserver agreement and agreement with cardiac CT than visual assessment.

2.
Korean Journal of Radiology ; : 1034-1043, 2021.
Artículo en Inglés | WPRIM | ID: wpr-902443

RESUMEN

Objective@#The purpose of this meta-analysis was to investigate the pooled agreements of the coronary artery calcium (CAC) severities assessed by electrocardiogram (ECG)-gated and non-ECG-gated CT and evaluate the impact of the scan parameters. @*Materials and Methods@#PubMed, EMBASE, and the Cochrane library were systematically searched. A modified Quality Assessment of Diagnostic Accuracy Studies-2 tool was used to evaluate the quality of the studies. Meta-analytic methods were utilized to determine the pooled weighted bias, limits of agreement (LOA), and the correlation coefficient of the CAC scores or the weighted kappa for the categorization of the CAC severities detected by the two modalities. The heterogeneity among the studies was also assessed. Subgroup analyses were performed based on factors that could affect the measurement of the CAC score and severity: slice thickness, reconstruction kernel, and radiation dose for non-ECG-gated CT. @*Results@#A total of 4000 patients from 16 studies were included. The pooled bias was 62.60, 95% LOA were -36.19 to 161.40, and the pooled correlation coefficient was 0.94 (95% confidence interval [CI] = 0.89–0.97) for the CAC score. The pooled weighted kappa of the CAC severity was 0.85 (95% CI = 0.79–0.91). Heterogeneity was observed in the studies (I2 > 50%, p < 0.1). In the subgroup analysis, the agreement between the CAC categorizations was better when the two CT examinations had reconstructions based on the same slice thickness and kernel. @*Conclusion@#The pooled agreement of the CAC severities assessed by the ECG-gated and non-ECG-gated CT was excellent; however, it was significantly affected by scan parameters, such as slice thickness and the reconstruction kernel.

3.
Korean Journal of Radiology ; : 1034-1043, 2021.
Artículo en Inglés | WPRIM | ID: wpr-894739

RESUMEN

Objective@#The purpose of this meta-analysis was to investigate the pooled agreements of the coronary artery calcium (CAC) severities assessed by electrocardiogram (ECG)-gated and non-ECG-gated CT and evaluate the impact of the scan parameters. @*Materials and Methods@#PubMed, EMBASE, and the Cochrane library were systematically searched. A modified Quality Assessment of Diagnostic Accuracy Studies-2 tool was used to evaluate the quality of the studies. Meta-analytic methods were utilized to determine the pooled weighted bias, limits of agreement (LOA), and the correlation coefficient of the CAC scores or the weighted kappa for the categorization of the CAC severities detected by the two modalities. The heterogeneity among the studies was also assessed. Subgroup analyses were performed based on factors that could affect the measurement of the CAC score and severity: slice thickness, reconstruction kernel, and radiation dose for non-ECG-gated CT. @*Results@#A total of 4000 patients from 16 studies were included. The pooled bias was 62.60, 95% LOA were -36.19 to 161.40, and the pooled correlation coefficient was 0.94 (95% confidence interval [CI] = 0.89–0.97) for the CAC score. The pooled weighted kappa of the CAC severity was 0.85 (95% CI = 0.79–0.91). Heterogeneity was observed in the studies (I2 > 50%, p < 0.1). In the subgroup analysis, the agreement between the CAC categorizations was better when the two CT examinations had reconstructions based on the same slice thickness and kernel. @*Conclusion@#The pooled agreement of the CAC severities assessed by the ECG-gated and non-ECG-gated CT was excellent; however, it was significantly affected by scan parameters, such as slice thickness and the reconstruction kernel.

4.
Korean Journal of Radiology ; : 334-343, 2021.
Artículo en Inglés | WPRIM | ID: wpr-875287

RESUMEN

Objective@#We aimed to develop a prediction model for diagnosing severe aortic stenosis (AS) using computed tomography (CT) radiomics features of aortic valve calcium (AVC) and machine learning (ML) algorithms. @*Materials and Methods@#We retrospectively enrolled 408 patients who underwent cardiac CT between March 2010 and August 2017 and had echocardiographic examinations (240 patients with severe AS on echocardiography [the severe AS group] and 168 patients without severe AS [the non-severe AS group]). Data were divided into a training set (312 patients) and a validation set (96 patients). Using non-contrast-enhanced cardiac CT scans, AVC was segmented, and 128 radiomics features for AVC were extracted. After feature selection was performed with three ML algorithms (least absolute shrinkage and selection operator [LASSO], random forests [RFs], and eXtreme Gradient Boosting [XGBoost]), model classifiers for diagnosing severe AS on echocardiography were developed in combination with three different model classifier methods (logistic regression, RF, and XGBoost). The performance (c-index) of each radiomics prediction model was compared with predictions based on AVC volume and score. @*Results@#The radiomics scores derived from LASSO were significantly different between the severe AS and non-severe AS groups in the validation set (median, 1.563 vs. 0.197, respectively, p 0.05 for all). @*Conclusion@#Models based on the radiomics features of AVC and ML algorithms may perform well for diagnosing severe AS, but the added value compared to AVC volume and score should be investigated further.

5.
Korean Journal of Radiology ; : 263-280, 2021.
Artículo en Inglés | WPRIM | ID: wpr-875253

RESUMEN

Percutaneous transthoracic needle biopsy (PTNB) is one of the essential diagnostic procedures for pulmonary lesions. Its role is increasing in the era of CT screening for lung cancer and precision medicine. The Korean Society of Thoracic Radiology developed the first evidence-based clinical guideline for PTNB in Korea by adapting pre-existing guidelines. The guideline provides 39 recommendations for the following four main domains of 12 key questions: the indications for PTNB, pre-procedural evaluation, procedural technique of PTNB and its accuracy, and management of post-biopsy complications. We hope that these recommendations can improve the diagnostic accuracy and safety of PTNB in clinical practice and promote standardization of the procedure nationwide.

6.
Journal of the Korean Radiological Society ; : 324-336, 2020.
Artículo en Coreano | WPRIM | ID: wpr-901278

RESUMEN

Cardiovascular calcifications can occur in various cardiovascular diseases and can serve as a biomarker for cardiovascular event prediction. Advances in CT have enabled evaluation of calcifications in cardiovascular structures not only on ECG-gated CT but also on non-ECG-gated CT. Therefore, many studies have been conducted on the clinical relevance of cardiovascular calcifications in patients. In this study, we divided cardiovascular calcifications into three classes, i.e., coronary artery, thoracic aorta, and cardiac valve calcifications, which are closely associated with cardiovascular events. Further, we briefly described pericardial calcifications, which can be found incidentally. Since the start of lung cancer screening in Korea in the second half of 2019, the number of non-enhanced, non-ECG-gated, low-dose chest CT has been increasing, and the number of incidentally found cardiovascular calcifications has also been increasing. Therefore, understanding the relevance of cardiovascular calcifications on non-enhanced, non-ECG-gated, low-dose chest CT and their proper reporting are important for radiologists.

7.
Journal of the Korean Radiological Society ; : 324-336, 2020.
Artículo en Coreano | WPRIM | ID: wpr-893574

RESUMEN

Cardiovascular calcifications can occur in various cardiovascular diseases and can serve as a biomarker for cardiovascular event prediction. Advances in CT have enabled evaluation of calcifications in cardiovascular structures not only on ECG-gated CT but also on non-ECG-gated CT. Therefore, many studies have been conducted on the clinical relevance of cardiovascular calcifications in patients. In this study, we divided cardiovascular calcifications into three classes, i.e., coronary artery, thoracic aorta, and cardiac valve calcifications, which are closely associated with cardiovascular events. Further, we briefly described pericardial calcifications, which can be found incidentally. Since the start of lung cancer screening in Korea in the second half of 2019, the number of non-enhanced, non-ECG-gated, low-dose chest CT has been increasing, and the number of incidentally found cardiovascular calcifications has also been increasing. Therefore, understanding the relevance of cardiovascular calcifications on non-enhanced, non-ECG-gated, low-dose chest CT and their proper reporting are important for radiologists.

8.
Korean Journal of Radiology ; : 450-461, 2020.
Artículo en Inglés | WPRIM | ID: wpr-810998

RESUMEN

OBJECTIVE: We performed a meta-analysis to evaluate the agreement of cardiac computed tomography (CT) with cardiac magnetic resonance imaging (CMRI) in the assessment of right ventricle (RV) volume and functional parameters.MATERIALS AND METHODS: PubMed, EMBASE, and Cochrane library were systematically searched for studies that compared CT with CMRI as the reference standard for measurement of the following RV parameters: end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), or ejection fraction (EF). Meta-analytic methods were utilized to determine the pooled weighted bias, limits of agreement (LOA), and correlation coefficient (r) between CT and CMRI. Heterogeneity was also assessed. Subgroup analyses were performed based on the probable factors affecting measurement of RV volume: CT contrast protocol, number of CT slices, CT reconstruction interval, CT volumetry, and segmentation methods.RESULTS: A total of 766 patients from 20 studies were included. Pooled bias and LOA were 3.1 mL (−5.7 to 11.8 mL), 3.6 mL (−4.0 to 11.2 mL), −0.4 mL (5.7 to 5.0 mL), and −1.8% (−5.7 to 2.2%) for EDV, ESV, SV, and EF, respectively. Pooled correlation coefficients were very strong for the RV parameters (r = 0.87–0.93). Heterogeneity was observed in the studies (I2 > 50%, p < 0.1). In the subgroup analysis, an RV-dedicated contrast protocol, ≥ 64 CT slices, CT volumetry with the Simpson's method, and inclusion of the papillary muscle and trabeculation had a lower pooled bias and narrower LOA.CONCLUSION: Cardiac CT accurately measures RV volume and function, with an acceptable range of bias and LOA and strong correlation with CMRI findings. The RV-dedicated CT contrast protocol, ≥ 64 CT slices, and use of the same CT volumetry method as CMRI can improve agreement with CMRI.

9.
Korean Journal of Radiology ; : 1095-1103, 2020.
Artículo | WPRIM | ID: wpr-833584

RESUMEN

Objective@#The present study aimed to investigate whether quantitative dual-energy computed tomography (DECT) parametersoffer an incremental risk stratification benefit over the CT ventricular diameter ratio in patients with acute pulmonary embolism(PE) by using propensity score analysis. @*Materials and Methods@#This study was conducted on 480 patients with acute PE who underwent CT pulmonary angiography(CTPA) or DECT pulmonary angiography (DE CT-PA). This propensity-matched study population included 240 patients with acutePE each in the CTPA and DECT groups. Altogether, 260 (54.1%) patients were men, and the mean age was 64.9 years (64.9 ±13.5 years). The primary endpoint was all-cause death within 30 days. The Cox proportional hazards regression model was usedto identify associations between CT parameters and outcomes and to identify potential predictors. Concordance (C) statisticswere used to compare the prognoses between the two groups. @*Results@#In both CTPA and DECT groups, right to left ventricle diameter ratio ≥ 1 was associated with an increased risk of allcausedeath within 30 days (hazard ratio: 3.707, p< 0.001 and 5.573, p< 0.001, respectively). However, C-statisticsshowed no statistically significant difference between the CTPA and DECT groups for predicting death within 30 days(C-statistics: 0.759 vs. 0.819, p= 0.117). @*Conclusion@#Quantitative measurement of lung perfusion defect volume by DECT had no added benefit over CT ventriculardiameter ratio for predicting all-cause death within 30 days.

10.
Korean Journal of Radiology ; : 1265-1272, 2020.
Artículo | WPRIM | ID: wpr-833567

RESUMEN

Objective@#We investigated the prevalence of pneumonia in novel coronavirus disease 2019 (COVID-19) patients using chest radiographs to identify the characteristics of those with initially negative chest radiographs, who were positive for pneumonia on follow-up. @*Materials and Methods@#Retrospective cohort data of 236 COVID-19 patients were reviewed. Chest radiography was performed on admission, with serial radiographs obtained until discharge. The ‘positive conversion group’ was defined as patients whose initial chest radiographs were negative but were positive for pneumonia during follow-up. Patients with initially positive chest radiographs were defined as the ‘initial pneumonia group.’ Patients with negative initial and follow-up chest radiographs were defined as the ‘non-pneumonia group.’ Clinical and laboratory findings were compared between groups, and predictors of positive conversion were investigated. @*Results@#Among 236 patients, 108 (45.8%) were in the non-pneumonia group, 69 (29.2%) were in the initial pneumonia group, and 59 (25%) were in the positive conversion group. The patients in the ‘initial pneumonia group’ and ‘positive conversion group’ were older, had higher C-reactive protein (CRP) and lactate dehydrogenase levels, and lower absolute lymphocyte counts than those in the ‘non-pneumonia group’ (all p 0.5 mg/dL (OR: 3.91, 95% CI: 1.54–9.91, p = 0.004) were independent predictors for future development of pneumonia. @*Conclusion@#More than a half of COVID-19 patients initially had normal chest radiographs; however, elderly patients (≥ 45 years of age) with abnormal laboratory findings (elevated CRP and low absolute lymphocyte counts) developed pneumonia on follow-up radiographs.

11.
Journal of Korean Medical Science ; : e316-2020.
Artículo | WPRIM | ID: wpr-831556

RESUMEN

Background@#The predictors of poor prognosis in patients with coronavirus disease 2019 (COVID-19) using computed tomography (CT) have not been investigated in a large cohort.Therefore, the purpose of this study was to investigate the adverse initial CT features to predict poor prognosis in COVID-19. @*Methods@#From February to April 2020, 281 COVID-19 patients who underwent CT at the time of admission were included. We divided the patients into the severe and non-severe disease groups. The severe group included patients with severe pneumonia or critical events.Intensive care unit admission or death were the critical events in this study. We compared the clinical and CT findings between the severe and non-severe groups and investigated the prognostic factors and critical events of the severe group using the regression analysis. @*Results@#Among the 281 patients, 36 (12.8%) patients were in the severe group and 245 (87.2%) patients were in the non-severe group. Critical events occurred in 10 patients (3.6%).In the severe group, patients showed significantly more pneumonia with consolidation, crazy-paving appearance, pleural effusion, and higher CT scores than those in the non-severe group (all, p 5 (OR, 3.70; 95% CI, 1.44– 9.53; p = 0.007), old age (> 77 years, OR, 9.96; 95% CI, 3.78–26.28; p 5 (OR, 7.29; 95% CI, 1.37–38.68; p = 0.020), pleural effusion (OR, 5.67; 95% CI, 1.04–30.8; p = 0.045) and old age (OR, 8.6; 95% CI, 1.80–41.0; p = 0.007) were also significant predictors of critical events. @*Conclusion@#Pleural effusion and the extent of pneumonia on initial CT scans are associated with poor prognosis in patients with COVID-19.

12.
Korean Journal of Radiology ; : 1300-1310, 2019.
Artículo en Inglés | WPRIM | ID: wpr-760293

RESUMEN

OBJECTIVE: To measure the diagnostic accuracy of percutaneous transthoracic needle lung biopsies (PTNBs) on the basis of the intention-to-diagnose principle and identify risk factors for diagnostic failure of PTNBs in a multi-institutional setting. MATERIALS AND METHODS: A total of 9384 initial PTNBs performed in 9239 patients (mean patient age, 65 years [range, 20–99 years]) from January 2010 to December 2014 were included. The accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of PTNBs for diagnosis of malignancy were measured. The proportion of diagnostic failures was measured, and their risk factors were identified. RESULTS: The overall accuracy, sensitivity, specificity, PPV, and NPV were 91.1% (95% confidence interval [CI], 90.6–91.7%), 92.5% (95% CI, 91.9–93.1%), 86.5% (95% CI, 85.0–87.9%), 99.2% (95% CI, 99.0–99.4%), and 84.3% (95% CI, 82.7–85.8%), respectively. The proportion of diagnostic failures was 8.9% (831 of 9384; 95% CI, 8.3–9.4%). The independent risk factors for diagnostic failures were lesions ≤ 1 cm in size (adjusted odds ratio [AOR], 1.86; 95% CI, 1.23–2.81), lesion size 1.1–2 cm (1.75; 1.45–2.11), subsolid lesions (1.81; 1.32–2.49), use of fine needle aspiration only (2.43; 1.80–3.28), final diagnosis of benign lesions (2.18; 1.84–2.58), and final diagnosis of lymphomas (10.66; 6.21–18.30). Use of cone-beam CT (AOR, 0.31; 95% CI, 0.13–0.75) and conventional CT-guidance (0.55; 0.32–0.94) reduced diagnostic failures. CONCLUSION: The accuracy of PTNB for diagnosis of malignancy was fairly high in our large-scale multi-institutional cohort. The identified risk factors for diagnostic failure may help reduce diagnostic failure and interpret the biopsy results.


Asunto(s)
Humanos , Biopsia , Biopsia con Aguja Fina , Estudios de Cohortes , Tomografía Computarizada de Haz Cónico , Diagnóstico , Biopsia Guiada por Imagen , Neoplasias Pulmonares , Pulmón , Linfoma , Agujas , Oportunidad Relativa , Factores de Riesgo , Sensibilidad y Especificidad
13.
Journal of the Korean Radiological Society ; : 837-848, 2019.
Artículo en Coreano | WPRIM | ID: wpr-916846

RESUMEN

A low-dose chest CT is performed for early detection of lung cancer, but the CT scan frequently shows several incidental abnormalities. Identification of the incidental findings may enable early detection of diseases other than lung cancer, thereby improving the survival of the individual undergoing screening. However, insignificant incidental abnormalities may cause unnecessary additional examination and costs. It is crucial for radiologists to appropriately comprehend and report significant incidental abnormalities other than lung cancer for successful implementation of the national lung cancer screening program in Korea.

14.
Korean Journal of Radiology ; : 352-363, 2019.
Artículo en Inglés | WPRIM | ID: wpr-741429

RESUMEN

OBJECTIVE: We aimed to investigate the diagnostic accuracy of cardiac computed tomography (CT) for the detection of mitral valve (MV) prolapse in mitral regurgitation (MR) with surgical findings as the standard reference, and to assess the predictability of MV replacement based on morphologic CT findings. MATERIALS AND METHODS: A total of 156 patients who had undergone preoperative cardiac CT and subsequently received MV surgery due to severe MR were retrospectively enrolled. Non-repairable MV was defined when at least one of the following conditions was met: 1) anterior leaflet prolapse, 2) bi-leaflet prolapse, or 3) valve morphology (leaflet thickening, calcification, or mitral annular calcification [MAC]). Diagnostic performance of CT for the detection of the prolapsed segment was assessed with surgical findings as the standard reference. Logistic regression analysis was performed to evaluate the value of CT findings to predict actual valve replacement. RESULTS: During surgery, MV prolapse was identified in 72.1%. The sensitivity, specificity, and diagnostic accuracy for the detection of MV prolapse were 99.1%, 81.4%, and 94.2%, respectively, per patient. One-hundred eighteen patients (75.6%) underwent MV repair and the remaining 38 patients received MV replacement. Bi-leaflet prolapse and valve morphology were independent predictors of valve replacement after adjusting for clinical variables (adjusted odds ratio, [OR] 8.63 for bi-leaflet prolapse; OR, 4.14 for leaflet thickening; and OR, 5.37 for leaflet calcium score > 5.6; p < 0.05). CONCLUSION: Cardiac CT can have high diagnostic performance for detecting the prolapsed segment of the MV and predictability of valve replacement before surgery. Bi-leaflet prolapse and valve morphology, such as leaflet thickening, or calcification or MAC, are the most important predictors of valve replacement.


Asunto(s)
Humanos , Calcio , Modelos Logísticos , Insuficiencia de la Válvula Mitral , Prolapso de la Válvula Mitral , Válvula Mitral , Oportunidad Relativa , Prolapso , Estudios Retrospectivos , Sensibilidad y Especificidad
15.
Korean Journal of Radiology ; : 531-531, 2019.
Artículo en Inglés | WPRIM | ID: wpr-741410

RESUMEN

On page 323, the grant number was incorrectly numbered as HI15C1234. The correct number is HI15C3390.

16.
Korean Journal of Radiology ; : 323-331, 2019.
Artículo en Inglés | WPRIM | ID: wpr-741394

RESUMEN

OBJECTIVE: To analyze the complications of percutaneous transthoracic needle biopsy using CT-based imaging modalities for needle guidance in comparison with fluoroscopy in a large retrospective cohort. MATERIALS AND METHODS: This study was approved by multiple Institutional Review Boards and the requirement for informed consent was waived. We retrospectively included 10568 biopsies from eight referral hospitals from 2010 through 2014. In univariate and multivariate logistic analyses, 3 CT-based guidance modalities (CT, CT fluoroscopy, and cone-beam CT) were compared with fluoroscopy in terms of the risk of pneumothorax, pneumothorax requiring chest tube insertion, and hemoptysis, with adjustment for other risk factors. RESULTS: Pneumothorax occurred in 2298 of the 10568 biopsies (21.7%). Tube insertion was required after 316 biopsies (3.0%), and hemoptysis occurred in 550 cases (5.2%). In the multivariate analysis, pneumothorax was more frequently detected with CT {odds ratio (OR), 2.752 (95% confidence interval [CI], 2.325–3.258), p < 0.001}, CT fluoroscopy (OR, 1.440 [95% CI, 1.176–1.762], p < 0.001), and cone-beam CT (OR, 2.906 [95% CI, 2.235–3.779], p < 0.001), but no significant relationship was found for pneumothorax requiring chest tube insertion (p = 0.497, p = 0.222, and p = 0.216, respectively). The incidence of hemoptysis was significantly lower under CT (OR, 0.348 [95% CI, 0.247–0.491], p < 0.001), CT fluoroscopy (OR, 0.594 [95% CI, 0.419–0.843], p = 0.004), and cone-beam CT (OR, 0.479 [95% CI, 0.317–0.724], p < 0.001) guidance. CONCLUSION: Hemoptysis occurred less frequently with CT-based guidance modalities in comparison with fluoroscopy. Although pneumothorax requiring chest tube insertion showed a similar incidence, pneumothorax was more frequently detected using CT-based guidance modalities.


Asunto(s)
Biopsia , Biopsia con Aguja , Tubos Torácicos , Estudios de Cohortes , Tomografía Computarizada de Haz Cónico , Comités de Ética en Investigación , Fluoroscopía , Hemoptisis , Biopsia Guiada por Imagen , Incidencia , Consentimiento Informado , Neoplasias Pulmonares , Análisis Multivariante , Agujas , Neumotórax , Derivación y Consulta , Estudios Retrospectivos , Factores de Riesgo
17.
Korean Journal of Radiology ; : 113-131, 2017.
Artículo en Inglés | WPRIM | ID: wpr-208830

RESUMEN

Cardiac magnetic resonance (CMR) imaging is widely used in various medical fields related to cardiovascular diseases. Rapid technological innovations in magnetic resonance imaging in recent times have resulted in the development of new techniques for CMR imaging. T1 and T2 image mapping sequences enable the direct quantification of T1, T2, and extracellular volume fraction (ECV) values of the myocardium, leading to the progressive integration of these sequences into routine CMR settings. Currently, T1, T2, and ECV values are being recognized as not only robust biomarkers for diagnosis of cardiomyopathies, but also predictive factors for treatment monitoring and prognosis. In this study, we have reviewed various T1 and T2 mapping sequence techniques and their clinical applications.


Asunto(s)
Biomarcadores , Cardiomiopatías , Enfermedades Cardiovasculares , Diagnóstico , Matriz Extracelular , Corazón , Invenciones , Imagen por Resonancia Magnética , Miocardio , Pronóstico
18.
Yonsei Medical Journal ; : 1243-1251, 2016.
Artículo en Inglés | WPRIM | ID: wpr-79767

RESUMEN

PURPOSE: We investigated factors predictive of false-negative pulmonary lesions with nonspecific benign cytology results on percutaneous transthoracic fine-needle aspiration biopsy (FNAB). MATERIALS AND METHODS: We included 222 pulmonary lesions that had a nonspecific benign result from percutaneous transthoracic FNAB between March 2005 and December 2012, and were confirmed by subsequent pathologic results or adequate clinical follow up over at least 2 years. Clinical, imaging, and biopsy procedure-related findings were compared between lesions with a final diagnosis of malignancy (false-negative) and lesions with a benign diagnosis (true-negative). Multivariate logistic regression analysis was performed to identify significant predictors of false-negatives. RESULTS: Of 222 lesions, 115 lesions were proved to be false-negatives, and 107 were true-negatives. Compared with the true-negatives, false-negative lesions showed significantly older age (p=0.037), higher maximum standardized uptake value (SUVmax) on positron emission tomography (p=0.001), larger lesion size (p=0.007), and lesion characteristics of a subsolid nodule (p=0.007). On multivariate logistic regression analysis, SUVmax, lesion size, and lesion characteristics were significant predictors of false-negative results. CONCLUSION: Among the clinical, radiologic, and procedure-related factors analyzed, high SUVmax, large lesion size, and subsolid lesions were useful for predicting malignancy in pulmonary lesions with nonspecific benign cytology results on FNAB.


Asunto(s)
Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Biopsia con Aguja Fina/métodos , Estudios de Cohortes , Citodiagnóstico , Reacciones Falso Negativas , Pulmón/patología , Enfermedades Pulmonares/diagnóstico , Estudios Retrospectivos
19.
Korean Journal of Radiology ; : 1012-1023, 2015.
Artículo en Inglés | WPRIM | ID: wpr-163302

RESUMEN

OBJECTIVE: The aims of this study were to compare opening and closing angles of normally functioning mechanical aortic valves measured on dual-source computed tomography (CT) with the manufacturers' values and to compare CT-measured opening angles according to valve function. MATERIALS AND METHODS: A total of 140 patients with 10 different types of mechanical aortic valves, who underwent dual-source cardiac CT, were included. Opening and closing angles were measured on CT images. Agreement between angles in normally functioning valves and the manufacturer values was assessed using the interclass coefficient and the Bland-Altman method. CT-measured opening angles were compared between normal functioning valves and suspected dysfunctioning valves. RESULTS: The CT-measured opening angles of normally functioning valves and manufacturers' values showed excellent agreement for seven valve types (intraclass coefficient [ICC], 0.977; 95% confidence interval [CI], 0.962-0.987). The mean differences in opening angles between the CT measurements and the manufacturers' values were 1.2degrees in seven types of valves, 11.0degrees in On-X valves, and 15.5degrees in ATS valves. The manufacturers' closing angles and those measured by CT showed excellent agreement for all valve types (ICC, 0.953; 95% CI, 0.920-0.972). Among valves with suspected dysfunction, those with limitation of motion (LOM) and an increased pressure gradient (PG) had smaller opening angles than those with LOM only (p < 0.05). CONCLUSION: Dual-source cardiac CT accurately measures opening and closing angles in most types of mechanical aortic valves, compared with the manufacturers' values. Opening angles on CT differ according to the type of valve dysfunction and a decreased opening angle may suggest an elevated PG.


Asunto(s)
Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Válvula Aórtica/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/terapia , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos
20.
Annals of Rehabilitation Medicine ; : 770-775, 2012.
Artículo en Inglés | WPRIM | ID: wpr-184675

RESUMEN

OBJECTIVE: To clarify factors affecting bone mineral density (BMD) in adults with cerebral palsy (CP). METHOD: Thirty-five patients with CP participated in this study. Demographic data including gender, age, body mass index (BMI), subtype according to neuromotor type and topographical distribution, ambulatory function, and functional independence measure (FIM) were investigated. The BMD of the lumbar spine and femur were measured using Dual-energy X-ray absorptiometry, and the factors affecting BMD were analyzed. RESULTS: The BMD had no significant association with factors such as gender, age, and subtype in adults with CP. However, BMI was significantly correlated with the BMD of lumbar spine and femur (p<0.05). The FIM score was also positively correlated with the BMD of femur (p<0.05). Moreover, CP patients with higher ambulatory function had significantly higher BMD of femur (p<0.05). CONCLUSION: These findings suggest that BMI and functional levels such as FIM and ambulatory function can affect BMD in adults with CP. The results might be used as basic data, suggesting the importance of treatment including weight bearing exercise and gait training in adults with CP.


Asunto(s)
Adulto , Humanos , Absorciometría de Fotón , Índice de Masa Corporal , Densidad Ósea , Parálisis Cerebral , Fémur , Marcha , Columna Vertebral , Soporte de Peso
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA