Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Añadir filtros








Intervalo de año
1.
Journal of Forensic Medicine ; (6): 114-118, 2022.
Artículo en Inglés | WPRIM | ID: wpr-984105

RESUMEN

OBJECTIVES@#To compare the application effect of microwave digestion - vacuum filtration - automated scanning electron microscopy (MD-VF-Auto SEM) method and plankton gene multiplex PCR system in the diagnosis of drowning.@*METHODS@#Lung, liver and kidney tissue of 10 non-drowning cases and 50 drowning cases were prepared for further MD-VF-Auto SEM method analysis and plankton gene multiplex PCR system analysis. The positive detection rate of the two methods in each tissue was calculated.@*RESULTS@#The positive rate of the MD-VF-Auto SEM method detecting diatoms in drowning cases was 100%, and few diatoms were detected in the liver and kidney tissues of 6 non-drowning cases. By using the plankton gene multiplex PCR system, the diatom positive rate of drowning cases was 84%, and all the non-drowning cases were negative. There were significant differences in the positive rate of the liver, kidney tissues between MD-VF-Auto SEM method and plankton gene multiplex PCR system (P<0.05), as well as the total positive rate of cases. However, no significant differences were found in the positive rates of lung tissues (P>0.05).@*CONCLUSIONS@#MD-VF-Auto SEM method is more sensitive than plankton gene multiplex PCR system in diatom test. But the plankton gene multiplex PCR system can also detect plankton other than diatoms. Combination of the two methods can provide a more reliable basis for the diagnosis of drowning.


Asunto(s)
Humanos , Diatomeas/genética , Ahogamiento/diagnóstico , Hígado , Pulmón , Microscopía Electrónica de Rastreo , Reacción en Cadena de la Polimerasa Multiplex , Plancton/genética
2.
Journal of Forensic Medicine ; (6): 110-113, 2022.
Artículo en Inglés | WPRIM | ID: wpr-984104

RESUMEN

OBJECTIVES@#To retrospectively analyze diatom test cases of corpses in water and discuss the value of quantitative analysis of diatoms in the diagnosis of drowning.@*METHODS@#A total of 490 cases of water-related death were collected. They were divided into drowning group and postmortem immersion group according to the cause of death. Diatoms in lung, liver, kidney tissue and water sample were analyzed quantitatively by microwave digestion-vacuum filtration-automated scanning electron microscopy (MD-VF-Auto SEM) method. The ratios of content of diatoms in lung tissue and water sample (CL/CD) were calculated.@*RESULTS@#The results of diatom test for three organs (lung, liver and kidney) were all positive in 400 cases (85.5%); the content of diatom in lung, liver, kidney tissues, and water samples of drowning group were (113 235.9±317 868.1), (26.7±75.6), (23.3±52.2) and (12 113.3±21 760.0) cells/10 g, respectively; the species of diatom were (7.5±2.8), (2.6±1.9), (2.9±2.1) and (8.9±3.0) types, respectively; the CL/CD of drowning group and postmortem immersion group were (100.6±830.7) and (0.3±0.4), respectively.@*CONCLUSIONS@#Quantitative analysis of diatoms can provide supportive evidence for the diagnosis of drowning, and the parameter CL/CD can be introduced into the analysis to make a more accurate diagnosis of drowning.


Asunto(s)
Humanos , Autopsia , Diatomeas , Ahogamiento/diagnóstico , Pulmón , Estudios Retrospectivos , Agua
3.
Journal of Forensic Medicine ; (6): 77-81, 2022.
Artículo en Inglés | WPRIM | ID: wpr-984099

RESUMEN

OBJECTIVES@#To study the effects of temperature and time for diatoms digestion and find out suitable digestive temperature and time.@*METHODS@#Eighty pieces of liver tissues were collected, each piece of tissue was 2 g, and 2 mL Pearl River water was added to each piece of tissue. The digestion temperature was set at 100 ℃, 120 ℃, 140 ℃, 160 ℃, 180 ℃ and the digestion time was set at 40, 50, 60, 70, 80 min. The liver tissue and water mixture were divided into 8 portions in each group. All the samples were tested by microwave digestive - vacuum filtration - automated scanning electron microscopy method. The quantity of diatom recovered and the quality of residue on the membrane were recorded.@*RESULTS@#When the digestion time was set to 60 min, there were statistically significant differences in the number of diatoms recovered at different temperatures (P<0.05). The maximum number of diatoms recovered was (28 797.50±6 009.67) at 140 ℃, and the minimum residue was (0.60±0.28) mg at 180 ℃. When the digestion temperature was set at 140 ℃, there were statistically significant differences in the number of diatoms recovered at different digestion times (P<0.05). The number of diatoms recovered was the highest at 40 min, it was up to (20 650.88±1 950.29), and the residue quality of each group had no statistical significance among different digestion time groups(P>0.05).@*CONCLUSIONS@#The effect of diatom digestion is related to temperature and time. When the digestion temperature was 140 ℃ and the digestion time was 40, 50 and 60 min, it is favorable for diatom test.


Asunto(s)
Diatomeas , Ahogamiento , Patologia Forense/métodos , Temperatura , Agua
4.
Journal of Forensic Medicine ; (6): 67-70, 2022.
Artículo en Inglés | WPRIM | ID: wpr-984097

RESUMEN

OBJECTIVES@#To study whether diatoms can enter the body through the lymphatic system of the digestive tract.@*METHODS@#Twenty experimental rabbits were divided into the test group and the control group randomly, and intragastric administration was performed with 20 mL water sample from the Pearl River and 20 mL ultrapure water, respectively. After 30 min, lymph, lungs, livers and kidneys were extracted for the diatom test. The concentration, size and type of diatoms were recorded.@*RESULTS@#The concentration of diatoms of the test group was higher than that of the control group (P<0.05). In the test group, Stephanodiscus, Coscinodiscus, Cyclotella, Melosira, Nitzschia, Synedra, Cymbella, and Navicula were detected; in the control group, Stephanodiscus, Coscinodiscus and Cyclotella were detected. The long diameter and the short diameter of diatoms of the test group were higher than those of the control group (P<0.05). In the test group, 1-2 diatoms were detected in 3 lung samples and 2 liver samples, which were Stephanodiscus or Cyclotella, and no diatoms were detected in the kidney samples; in the control group, 1-2 diatoms were detected in 2 lung samples and 3 liver samples, which were Stephanodiscus or Coscinodiscus, and no diatoms were detected in the kidney samples.@*CONCLUSIONS@#Diatoms can enter the body through the lymphatic fluid, which is one of the reasons for the presence of diatoms in tissues and organs of non-drowning cadavers.


Asunto(s)
Animales , Conejos , Diatomeas , Ahogamiento , Tracto Gastrointestinal , Pulmón , Sistema Linfático , Agua/metabolismo
5.
Journal of Forensic Medicine ; (6): 40-45, 2022.
Artículo en Inglés | WPRIM | ID: wpr-984093

RESUMEN

OBJECTIVES@#To explore the application values of diatom artificial intelligence (AI) search system in the diagnosis of drowning.@*METHODS@#The liver and kidney tissues of 12 drowned corpses were taken and were performed with the diatom test, the view images were obtained by scanning electron microscopy (SEM). Diatom detection and forensic expert manual identification were carried out under the thresholds of 0.5, 0.7 and 0.9 of the diatom AI search system, respectively. Diatom recall rate, precision rate and image exclusion rate were used to detect and compare the efficiency of diatom AI search system.@*RESULTS@#There was no statistical difference between the number of diatoms detected in the target marked by the diatom AI search system and the number of diatoms identified manually (P>0.05); the recall rates of the diatom AI search system were statistically different under different thresholds (P<0.05); the precision rates of the diatom AI system were statistically different under different thresholds(P<0.05), and the highest precision rate was 53.15%; the image exclusion rates of the diatom AI search system were statistically different under different thresholds (P<0.05), and the highest image exclusion rate was 99.72%. For the same sample, the time taken by the diatom AI search system to identify diatoms was only 1/7 of that of manual identification.@*CONCLUSIONS@#Diatom AI search system has a good application prospect in drowning cases. Its automatic diatom search ability is equal to that of experienced forensic experts, and it can greatly reduce the workload of manual observation of images.


Asunto(s)
Humanos , Inteligencia Artificial , Diatomeas , Ahogamiento/diagnóstico , Hígado , Pulmón , Microscopía Electrónica de Rastreo
6.
Biomedical and Environmental Sciences ; (12): 255-263, 2017.
Artículo en Inglés | WPRIM | ID: wpr-296489

RESUMEN

<p><b>OBJECTIVE</b>To assess the test-retest reliability and criterion validity of the Simplified Chinese-character version of the International Physical Activity Questionnaire Long form (IPAQ-L) in urban community-dwelling adults in Hanghzou, China.</p><p><b>METHODS</b>A total of 158 eligible participants aged 25-59 years from 6 neighbourhoods in two central districts of Hangzhou completed the IPAQ-L questionnaire twice within a 7-day interval. Half of the subjects wore pedometers during the first 7 days. Test-retest reliability was examined by comparing the first (Day 1) and the second (Day 9) survey of IPAQ-L. Criterion validity was assessed by comparing IPAQ-L with pedometer data.</p><p><b>RESULTS</b>Modest to good test-retest reliability was found with intraclass correlation coefficients of 0.67 for total PA, 0.37 to 0.73 for specific dimensions, and 0.56 to 0.71 for different intensities of PA. Total PA measured by IPAQ-L was moderately correlated with exercise levels (partial r = 0.27, P = 0.020) and walking distance (partial r = 0.31, P = 0.007), which were measured by a pedometer, after adjusting for gender, age, educational attainment and employment status.</p><p><b>CONCLUSION</b>Our results indicate that the IPAQ-L is a reliable and validated measure for assessing physical activity levels in this population and possibly the adult population in other mainland Chinese cities.</p>


Asunto(s)
Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , China , Estudios Transversales , Ejercicio Físico , Reproducibilidad de los Resultados , Encuestas y Cuestionarios , Estándares de Referencia , Población Urbana
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA