Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Zhonghua nankexue ; Zhonghua nankexue;(12): 635-640, 2016.
Artículo en Chino | WPRIM | ID: wpr-304698

RESUMEN

<p><b>Objective</b>To investigate the application value of Toshiba 320-row dynamic volumetric CT angiography in the diagnosis of venous erectile dysfunction (VED).</p><p><b>METHODS</b>We enrolled in this study 33 patients diagnosed with ED by audiovisual sexual stimulation screening in the outpatient department. Penile erection was induced in the patients by injection of 2 mg phentolamine plus 30 mg papaverine into the corpus cavernosum, followed by that of contrast agent of iobitridol through the vein and corpus cavernosum successively. Then 320-row dynamic volumetric CT angiography was performed and the images of the corpus cavernosum in the arterial and venous phases were collected and processed.</p><p><b>RESULTS</b>Different degrees of abnormal venous drainage were observed in 29 of the patients, including 7 cases (24.1%) of back deep venous leakage, 6 cases (20.7%) of foot venous leakage, 3 cases (10.3%) of dorsal superficial venous leakage, 1 case (3.5%) of intervertebral venous leakage, 2 cases (6.9%) of cavernous venous leakage, and 10 cases (34.5%) of mixed venous leakage. Ten of the patients underwent surgery, dorsal deep penile vein ligation in 2 cases, dorsal deep vein embedding plus foot vein ligation in 4, and foot vein ligation in the other 4. Eight of the patients were followed up for 3-12 months post-operatively, during which 2 achieved obvious erectile improvement, while the other 6 gained normal penile erection.</p><p><b>CONCLUSIONS</b>Toshiba 320-row dynamic volumetric CT angiography is a reliable method for the diagnosis of VED, which displays the precise location of venous leakage for clinical treatment, with the advantages of clearer images, lower doses of contrast agent and radiation, and faster examination than X-ray penile angiography.</p>


Asunto(s)
Adulto , Humanos , Masculino , Persona de Mediana Edad , Arterias , Diagnóstico por Imagen , Angiografía por Tomografía Computarizada , Medios de Contraste , Combinación de Medicamentos , Disfunción Eréctil , Diagnóstico por Imagen , Inyecciones , Yohexol , Ligadura , Papaverina , Erección Peniana , Pene , Diagnóstico por Imagen , Fentolamina , Venas , Diagnóstico por Imagen , Cirugía General
2.
Zhonghua xinxueguanbing zazhi ; (12): 487-491, 2012.
Artículo en Chino | WPRIM | ID: wpr-275019

RESUMEN

<p><b>OBJECTIVE</b>To evaluate the diagnostic accuracy of 320-slice CT coronary angiography (CTA) in the evaluation of in-stent restenosis (ISR, ≥50% luminal narrowing) in comparison with quantitative coronary angiography (CAG).</p><p><b>METHODS</b>A total of 69 patients with previous stent implantation who underwent both CTA and CAG were prospectively included. We assessed diagnostic valve for ISR with CTA in comparison with CAG.</p><p><b>RESULTS</b>A total of 110 stents were implanted in these patients.CAG identified 14 ISR. CTA correctly identified 13 ISR and misdiagnosed 5 ISR in stents without ISR. Besides, 6 stents could not be evaluated by CTA due to unsatisfied image quality. Accordingly, sensitivity, specificity, positive and negative predictive value of CTA for diagnosing ISR were 93%, 89%, 54% and 99%, respectively. The image quality of CTA was significantly better in larger stents (percentages of good and moderate stent image of ≥3.0 mm and <3.0 mm: 56% vs. 27%, 25% vs. 49%) and which was linked with better diagnostic coincidence rate (95% vs. 78%) for larger stents. The image quality of CTA was significantly better in stents with thinner stent strut thickness (percentages of poor CTA stent image quality of stent strut thickness<140 µm and ≥140 µm: 12% vs. 45%, P<0.01) and which was associated with better diagnostic coincidence rate for stents with thinner stent strut thickness (94% vs. 76%, P<0.05). The image quality of CTA was also significantly better in single stent (percentages of poor CTA stent image quality of single stent vs. overlap and dedicated stent: 17% vs. 36%, P<0.05). However, heart rate (≥65 beats/min vs. <65 beats/min) during CTA acquisition was not associated with image quality and the diagnostic coincidence rate (all P>0.05).</p><p><b>CONCLUSIONS</b>Our results indicate that 320-slice CTA allows accurate noninvasive assessment of significant in-stent restenosis in selected patients. Stents with a large diameter and thin struts are associated with better image quality and higher diagnostic accuracy.</p>


Asunto(s)
Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Angiografía Coronaria , Reestenosis Coronaria , Diagnóstico por Imagen , Valor Predictivo de las Pruebas , Estudios Prospectivos , Sensibilidad y Especificidad , Stents , Tomografía Computarizada por Rayos X , Métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA