Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Añadir filtros








Intervalo de año
1.
Chongqing Medicine ; (36): 1052-1054, 2018.
Artículo en Chino | WPRIM | ID: wpr-691909

RESUMEN

Objective To understand the frequency distribution of CYP2C9 and VKORC1 gene single nucleotide polymor-phisms in Yunnan Han population.Methods CYP2C9(430C> T,1075A>C and 1080C> G)locus and VKORC1(-1639G> A and 1173C> T)locus gene polymorphisms in 202 samples were detected by adopting electrochemical gene sensor method,and the allele frequencies and genotype frequencies were performed the statistics and the gene polymorphism in relevant populations was an-alyzed.Results Among 202 samples,202 cases(100.0%)were genotype C/C at CYP2C9 * 2 locus,C allele frequency was 100.0%;185 cases(91.6%)were genotype A/A at CYP2C9*3 locus,15 cases(7.4%)were A/C genotype,2 cases(1.0%)were C/C genotype,A allele frequency was 95.3%,C allele frequency was 4.7%;CYP2C9*5 locus genotype C/C was in 202 cases (100.0%),C allele frequency was 100%;VKORC1 -1639G > A locus genotype A/A was in 145 cases(71.8%),57 cases (28.2%)were G/A genotype,A allele frequency was 85.9%,G was 14.1%;1173C> T locus genotype T/T was in 145 cases (71.8%),C/T gene type in 57 cases(28.2%),T allele frequency was 85.9%,and C was 14.1%.Conclusion The distribution of CYP2C9 gene in Yunnan Han population is similar to that in other regions of our country.The VKORC1 gene is different from the foreign population,Chinese Han nationality and partial minority nationalities.

2.
International Journal of Laboratory Medicine ; (12): 2708-2709,2712, 2016.
Artículo en Chino | WPRIM | ID: wpr-605605

RESUMEN

Objective To study on the application of biological variation total allowable error in quality management of serum lipid detection .Methods The σ score ,quality goal index (QGI) ,priority improvement measures and performance evaluation of lipid accuracy criteria were evaluated ,including cholesterol (CHOL) ,triglyceride (TG) ,high density lipoprotein (HDL‐C) ,low density lipoprotein (LDL‐C) ,which included in the standard of accuracy of the Ministry of Health in 2015 .The reason for unsatisfactory re‐sults of cholesterol (CHOL) test were analyzed .Results Based on the three levels of quality specifications derived in biological var‐iation ,when the total allowable error was located at an appropriate level ,the σ score of TG ,HDL‐C ,LDL‐C reached 6 ,it was not re‐quired for improvement .While the score of CHOL performance analysis was poor ,accuracy was required to give priority to impro‐ving .When the total allowable error reached the best level ,only the σ score of TG achieved “good” in the four items ,improvement of precision was needed .When the total allowable error was located at the lowest level ,the σ score of TG ,HDL‐C ,LDL‐C was grea‐ter than 6 ,the score of performance analysis reached the “excellent” .The σ score of CHOL (2 .9) had been closen to 3σ ,accuracy was required to be corrected .Conclusion The biological variation derived total allowable error is easy to meet the requirements of the quality management in serum lipid determination by current technologies and methods .The theory of 6σ quality can reflect the performance of detection indexes ,and improve the quality of analysis effectively .

3.
International Journal of Laboratory Medicine ; (12): 498-500, 2015.
Artículo en Chino | WPRIM | ID: wpr-462127

RESUMEN

Objective To verify and confirm the optical performance of the Olympus AU5400 Automatic Analyzer is satisfied for the professional requirements.Methods According to the Medical Standard of the People's Republic of China:Automatic chemistry analyzer(YY/T 0654-2008),the Analyzer Modular Ⅰand Ⅱ optical performance were measured to verify the stray light,the ab-sorption accuracy,linear range,stability and repeatability.Results The stray light absorption of tow modular was 4.789 4-5.158 9;The absorption accuracy of potassium dichromate standard solution (1-1)was (-0.002 1--0.024 7),and solution (1-2)was (-0.008 6--0.067 7);The D-value of stability that the highest absorption of standard solution (1-1)minus the lowest was 0.000 5-0.001 5;The CV% of repeatability for standard solution (1-2)was 0.02%-0.04%;Therof absorption linear was 0.999 6-0.999 9. Conclusion The optical performance of Olympus AU5400 Analyzer conforms to the standard of YY/T 0654-2008.

4.
International Journal of Laboratory Medicine ; (12): 3415-3416, 2014.
Artículo en Chino | WPRIM | ID: wpr-457633

RESUMEN

Objective To analyze the precision and accuracy of the Olympus AU5421 automatic biochemical analyzer in order to verify the performance of this detection system declared by the manufacturer.Methods The Precision and Accuracy of User Au-thentication-Guide for Approval Second Edition(CLSI EP15-A2)was used to perform the routine detection on the Olympus AU5421 automatic biochemical analyzer.The systematic precision and accuracy were analyzed.Results Under this experiment condition,the precision and accuracy of the Olympus AU5421 automatic biochemical analyzer was consistent with the performance declared by the manufacturer.Conclusion The Olympus AU5421 automatic biochemical analyzer system has the high precision and good accuracy, and can be better applied in the clinical routine detection.

5.
Chinese Journal of Hospital Administration ; (12)1996.
Artículo en Chino | WPRIM | ID: wpr-673651

RESUMEN

Objective To seek a rational method of estimating the demands for medical services so as to work out regional health planning in a scientific way. Methods A metropolis including 19 counties and districts was selected as a region and demands for medical services were forecasted via retrospective analysis and the econometric model. Results A model of the demands for outpatient and inpatient services was obtained based on the impact of many social and economic factors on medical health services, and illustrations were given to indicate the demands for medical health services in the 19 counties and districts in future when prices should rise by 15% and 20%. Conclusion The econometric model can be used as a tool for estimating the demands for medical health services, and yet improvements need to be made.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA