Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Añadir filtros








Intervalo de año
1.
Artículo en Inglés | WPRIM | ID: wpr-1044816

RESUMEN

Objective@#To evaluate the diagnostic performance and image quality of 1.5-mm slice thickness MRI with deep learningbased image reconstruction (1.5-mm MRI + DLR) compared to routine 3-mm slice thickness MRI (routine MRI) and 1.5-mm slice thickness MRI without DLR (1.5-mm MRI without DLR) for evaluating temporal lobe epilepsy (TLE). @*Materials and Methods@#This retrospective study included 117 MR image sets comprising 1.5-mm MRI + DLR, 1.5-mm MRI without DLR, and routine MRI from 117 consecutive patients (mean age, 41 years; 61 female; 34 patients with TLE and 83 without TLE). Two neuroradiologists evaluated the presence of hippocampal or temporal lobe lesions, volume loss, signal abnormalities, loss of internal structure of the hippocampus, and lesion conspicuity in the temporal lobe. Reference standards for TLE were independently constructed by neurologists using clinical and radiological findings. Subjective image quality, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were analyzed. Performance in diagnosing TLE, lesion findings, and image quality were compared among the three protocols. @*Results@#The pooled sensitivity of 1.5-mm MRI + DLR (91.2%) for diagnosing TLE was higher than that of routine MRI (72.1%, P < 0.001). In the subgroup analysis, 1.5-mm MRI + DLR showed higher sensitivity for hippocampal lesions than routine MRI (92.7% vs. 75.0%, P = 0.001), with improved depiction of hippocampal T2 high signal intensity change (P = 0.016) and loss of internal structure (P < 0.001). However, the pooled specificity of 1.5-mm MRI + DLR (76.5%) was lower than that of routine MRI (89.2%, P = 0.004). Compared with 1.5-mm MRI without DLR, 1.5-mm MRI + DLR resulted in significantly improved pooled accuracy (91.2% vs. 73.1%, P = 0.010), image quality, SNR, and CNR (all, P < 0.001). @*Conclusion@#The use of 1.5-mm MRI + DLR enhanced the performance of MRI in diagnosing TLE, particularly in hippocampal evaluation, because of improved depiction of hippocampal abnormalities and enhanced image quality.

2.
Artículo en Inglés | WPRIM | ID: wpr-1044866

RESUMEN

Objective@#Differentiating intracranial aneurysms from normal variants using CT angiography (CTA) or MR angiography (MRA) poses significant challenges. This study aimed to evaluate the efficacy of proton-density MRA (PD-MRA) compared to highresolution time-of-flight MRA (HR-MRA) in diagnosing aneurysms among patients with indeterminate findings on conventional CTA or MRA. @*Materials and Methods@#In this retrospective analysis, we included patients who underwent both PD-MRA and HR-MRA from August 2020 to July 2022 to assess lesions deemed indeterminate on prior conventional CTA or MRA examinations. Three experienced neuroradiologists independently reviewed the lesions using HR-MRA and PD-MRA with reconstructed voxel sizes of 0.253 mm3 or 0.23 mm3 , respectively. A neurointerventionist established the gold standard with digital subtraction angiography.We compared the performance of HR-MRA, PD-MRA (0.253 -mm3 voxel), and PD-MRA (0.23 -mm3 voxel) in diagnosing aneurysms, both per lesion and per patient. The Fleiss kappa statistic was used to calculate inter-reader agreement. @*Results@#The study involved 109 patients (average age 57.4 ± 11.0 years; male:female ratio, 11:98) with 141 indeterminate lesions. Of these, 78 lesions (55.3%) in 69 patients were confirmed as aneurysms by the reference standard. PD-MRA (0.253 -mm3voxel) exhibited significantly higher per-lesion diagnostic performance compared to HR-MRA across all three readers: sensitivity ranged from 87.2%–91.0% versus 66.7%–70.5%; specificity from 93.7%–96.8% versus 58.7%–68.3%; and accuracy from 90.8%–92.9% versus 63.8%–69.5% (P ≤ 0.003). Furthermore, PD-MRA (0.253 -mm3 voxel) demonstrated significantly superior per-patient specificity and accuracy compared to HR-MRA across all evaluators (P ≤ 0.013). The diagnostic accuracy of PD-MRA (0.23 -mm3 voxel) surpassed that of HR-MRA and was comparable to PD-MRA (0.253 -mm3 voxel). The kappa values for inter-reader agreements were significantly higher in PD-MRA (0.820–0.938) than in HR-MRA (0.447–0.510). @*Conclusion@#PD-MRA outperformed HR-MRA in diagnostic accuracy and demonstrated almost perfect inter-reader consistency in identifying intracranial aneurysms among patients with lesions initially indeterminate on CTA or MRA.

3.
Korean Journal of Radiology ; : 1028-1037, 2023.
Artículo en Inglés | WPRIM | ID: wpr-1002415

RESUMEN

Objective@#To evaluate the computed tomography (CT) features for diagnosing metastatic cervical lymph nodes (LNs) in patients with differentiated thyroid cancer (DTC) and validate the CT-based risk stratification system suggested by the Korean Thyroid Imaging Reporting and Data System (K-TIRADS) guidelines. @*Materials and Methods@#A total of 463 LNs from 399 patients with DTC who underwent preoperative CT staging and ultrasound-guided fine-needle aspiration were included. The following CT features for each LN were evaluated: absence of hilum, cystic changes, calcification, strong enhancement, and heterogeneous enhancement. Multivariable logistic regression analysis was performed to identify independent CT features associated with metastatic LNs, and their diagnostic performances were evaluated. LNs were classified into probably benign, indeterminate, and suspicious categories according to the K-TIRADS and the modified LN classification proposed in our study. The diagnostic performance of both classification systems was compared using the exact McNemar and Kosinski tests. @*Results@#The absence of hilum (odds ratio [OR], 4.859; 95% confidence interval [CI], 1.593–14.823; P = 0.005), strong enhancement (OR, 28.755; 95% CI, 12.719–65.007; P < 0.001), and cystic changes (OR, 46.157; 95% CI, 5.07–420.234; P = 0.001) were independently associated with metastatic LNs. All LNs showing calcification were diagnosed as metastases. Heterogeneous enhancement did not show a significant independent association with metastatic LNs. Strong enhancement, calcification, and cystic changes showed moderate to high specificity (70.1%–100%) and positive predictive value (PPV) (91.8%–100%). The absence of the hilum showed high sensitivity (97.8%) but low specificity (34.0%). The modified LN classification, which excluded heterogeneous enhancement from the K-TIRADS, demonstrated higher specificity (70.1% vs. 62.9%, P = 0.016) and PPV (92.5% vs. 90.9%, P = 0.011) than the K-TIRADS. @*Conclusion@#Excluding heterogeneous enhancement as a suspicious feature resulted in a higher specificity and PPV for diagnosing metastatic LNs than the K-TIRADS. Our research results may provide a basis for revising the LN classification in future guidelines.

4.
Korean Journal of Radiology ; : 2026-2033, 2021.
Artículo en Inglés | WPRIM | ID: wpr-918189

RESUMEN

Objective@#The aim of this study was to compare the diagnostic performances of digital tomosynthesis (DTS) and conventional radiography in detecting osteonecrosis of the femoral head (ONFH) using computed tomography (CT), as the reference standard and evaluate the diagnostic reproducibility of DTS. @*Materials and Methods@#Forty-five patients (24 male and 21 female; age range, 25–77 years) with clinically suspected ONFH underwent anteroposterior radiography, DTS, and CT. Two musculoskeletal radiologists independently evaluated the presence and type of ONFH. The diagnostic performance of radiography and DTS in detecting the presence of ONFH and determining the types of ONFH were evaluated. The interobserver and intraobserver reliabilities of each imaging modality were analyzed using Cohen’s kappa. @*Results@#DTS had higher sensitivity (89.4%–100% vs. 74.5%–76.6%) and specificity (97.3%–100% vs. 78.4%–83.8%) for ONFH detection than radiography. DTS showed higher performance than radiography in identifying the subtypes of ONFH with statistical significance in one reader (type 1, 100% vs. 30.8%, p = 0.004; type II, 97.1% vs. 73.5%, p = 0.008). The interobserver agreement was excellent for DTS and moderate for radiography (kappa of 0.86 vs. 0.57, respectively). The intraobserver agreement for DTS was higher than that of radiography (kappa of 0.96 vs. 0.69, respectively). @*Conclusion@#DTS showed higher diagnostic performance and reproducibility than radiography in detecting ONFH. DTS may be used as a first-line diagnostic modality instead of radiography for patients suspected of having ONFH.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA