Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Añadir filtros








Intervalo de año
1.
Artículo en Chino | WPRIM | ID: wpr-1021783

RESUMEN

BACKGROUND:Patients with degenerative cervical spondylosis often suffer from changed varicosity of the cervical spine,unbalanced neck-shoulder muscular strength,and descending power. OBJECTIVE:To probe into the correlation between sagittal curvature parameters and pain threshold for neck-shoulder muscles in degenerative cervical spondylosis. METHODS:Totally 50 patients with degenerative cervical spondylosis received treatment at the 3D Printed Outpatient Center of Shanghai Ninth People's Hospital,Shanghai Jiao Tong University School of Medicine from January 2022 to March 2023 were included in the study.After excluding the 10 patients of cervical lateral projection that failed to meet the measurement conditions,the cervical lateral projections were shot to measure the following iconography parameters:Borden value and C2-7 Cobb angle as well as pain thresholds on the midpoint of the superior trapezius muscle in bilateral bundles and at 1 cm beside the C5-6 interspike.The correlation between sagittal curvature parameters and pain threshold of neck-shoulder muscles in degenerative cervical spondylosis was analyzed. RESULTS AND CONCLUSION:(1)The Borden value of sagittal curvature showed a moderately positive correlation with the bundle pain threshold in the left upper trapezius muscle,the bundle pain threshold in the right upper trapezius muscle,and the pain threshold at the 1 cm of the left side beside the C5-6 interspike(r=0.498,P<0.01;r=0.448,P<0.05;r=0.405,P<0.05)and a weak positive correlation with the pain threshold at the 1 cm of the right side beside the C5-6 interspike(r=0.322,P<0.05).(2)The C2-7 Cobb angle showed a weak positive correlation with the left squared myalgia threshold(r=0.355,P<0.05),and there was no correlation with the pain threshold of the left trapezius muscle and the pain threshold at the 1 cm of both sides beside the C5-6 interspike.(3)There was a correlation between the pain threshold of the neck-shoulder muscles,and a high correlation between the pain threshold of the left and right muscles and the pain threshold within the left and right side muscles,indicating that the neck-shoulder muscles are consistent and may be related to the coordination of the neck-shoulder movements.

2.
Artículo en Chino | WPRIM | ID: wpr-1021898

RESUMEN

BACKGROUND:Short-term wearing of cervical brace combined with shoulder and neck muscle exercise can significantly improve the symptoms of early cervical spondylosis.After stopping wearing cervical brace,patients'symptoms are easy to recur,which may be due to the lack of cervical curvature correction function. OBJECTIVE:To analyze the effect of 3D printed personalized cervical orthopedic brace for adjusting cervical curvature in the treatment of early cervical spondylosis. METHODS:From January 2021 to January 2023,30 patients with early cervical spondylosis in the Shanghai Fifth People's Hospital,Fudan University were studied,including 11 males and 19 females,with a mean age of(31.7±6.6)years old.All patients customized and wore 3D printed personalized cervical orthopedic braces for 3 hours a day for continuous 12 weeks.Borden value of cervical curvature,pain threshold of shoulder and neck muscles,cervical dysfunction index,and visual analog scale score in 30 patients were recorded before and 4 and 8 weeks after treatment. RESULTS AND CONCLUSION:(1)Compared with before treatment,the difference of Borden value of cervical curvature,right trapezius tenderness threshold,and cervical dysfunction index was not significant in 30 patients after 4 weeks of treatment(P>0.05).Visual analog scale score,left trapezius tenderness threshold,left and right C5C6 tenderness threshold were significantly improved(P<0.05).(2)Compared with before treatment,the cervical curvature Borden value,left and right trapezius tenderness threshold,visual analog scale score,left and right C5C6 tenderness threshold,and cervical dysfunction index of 30 patients were significantly improved after 12 weeks of treatment(P<0.05).(3)Compared with 4 weeks after treatment,the Borden value of cervical curvature,right trapezius tenderness threshold,visual analog scale score,left and right C5C6 tenderness threshold and cervical dysfunction index of 30 patients after 12 weeks of treatment were significantly improved(P<0.05).(4)The results show that short-term wearing of 3D printed personalized cervical orthopedic brace can improve the pain of patients with early cervical spondylosis,while long-term application has certain effect on the recovery of cervical curvature.

3.
Artículo en Chino | WPRIM | ID: wpr-1021935

RESUMEN

BACKGROUND:Red light therapy has the non-invasive and cost-effective characteristics,and is widely used in various acute and chronic pains in clinic.However,currently,the phototherapy equipment used in clinic is expensive and has certain site limitations,so it is necessary to explore more convenient and economical phototherapy applications. OBJECTIVE:To observe the clinical efficacy of a self-developed photon cervical vertebra massage instrument for chronic neck pain. METHODS:From November 2022 to February 2023,24 patients with chronic neck pain were recruited from the Department of Rehabilitation Medicine,Ninth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine,including 18 females and 6 males,with a mean age of(29.67±6.40)years.The body mass index was(21.39±3.52)kg/m2.Photon cervical vertebra massage instrument was used twice a day for 20 minutes each time for four weeks.The changes in visual analog scale score,pressure pain threshold,neck active activity,neck disability index,and Pittsburgh sleep quality index were observed before,after 2 and 4 weeks of treatment. RESULTS AND CONCLUSION:(1)Compared with before treatment,after four weeks of treatment,visual analog scale score,pressure pain threshold,neck disability index,and Pittsburgh sleep quality index were all improved(P<0.05),while some cervical motion(extension,left and right rotation)improved(P<0.05)after 4 weeks of treatment.(2)Bilateral visual analog scale scores,left trapezius muscle pressure pain threshold,C5C6 pressure pain threshold,and neck disability index improved after 2 weeks of treatment(P<0.05).(3)It is indicated that the application of photon cervical vertebra massage instrument can improve the pain score,muscle tenderness,sleep quality,functional level,and partial active activity of patients with chronic neck pain in a short period,and is a convenient,effective,and safe treatment method.

4.
Artículo en Chino | WPRIM | ID: wpr-1022068

RESUMEN

BACKGROUND:The study of the lumbar spine and pelvis in patients with Lenke type 5 lordosis is limited to the coronal and sagittal planes,and the three-dimensional relationship between the scoliosis and the pelvis has not yet been clarified. OBJECTIVE:To analyze the effect of lumbar scoliosis on the pelvis in patients with Lenke type 5 lordosis and to study the correlation between the lumbar spine and the three-dimensional spatial position of the pelvis. METHODS:Imaging data of 60 patients with Lenke type 5 lordosis scoliosis admitted to the 3D Printing Reception Center of Shanghai Ninth People's Hospital,Shanghai Jiao Tong University School of Medicine from January 2019 to September 2023 were retrospectively analyzed,including Cobb angle,coronal pelvic tilt,lumbar lordosis,left and right pelvic hip width ratio(sacroiliac-anterior superior iliac spine),spinal rotation angle,pelvic tilt,sacral slope,pelvic incidence,coronal deformity angular ratio,sagittal deformity angular ratio,C7 plumb line-center sacral vertical line,apical vertebral translation,and coronal sacral inclination.The information was summarized as a database.SPSS 22.0 software was used to analyze the data related to the lumbar spine and pelvis of the patients with Lenke type 5 primary lumbar curvature adolescent idiopathic scoliosis using Spearman's correlation analysis and linear regression. RESULTS AND CONCLUSION:(1)Cobb angle was highly positively correlated with coronal deformity angular ratio,apical vertebral translation,and spinal rotation angle(r=0.91,r=0.841,r=0.736).(2)Coronal deformity angular ratio was highly positively correlated with apical vertebral translation(r=0.737),moderately positively correlated with C7 plumb line-center sacral vertical line(r=0.514),and moderately negatively correlated with sagittal deformity angular ratio(r=-0.595).(3)There was a high positive correlation between lumbar lordosis and sagittal deformity angular ratio(r=0.942)and a moderate negative correlation with coronal deformity angular ratio(r=-0.554).(4)There was a moderate positive correlation between Cobb angle with coronal pelvic tilt and coronal sacral inclination(r=0.522,r=0.534)and a moderate positive correlation between C7 plumb line-center sacral vertical line and coronal pelvic tilt(r=0.507).Apical vertebral translation with coronal pelvic tilt and coronal sacral inclination showed a moderate positive correlation(r=0.507,r=0.506).Lumbar lordosis with sacral slope and pelvic incidence showed a moderate positive correlation(r=0.512,r=0.538).Sagittal deformity angular ratio was moderately positively correlated with sacral slope and pelvic incidence(r=0.614,r=0.621).(5)Studies have found that the relative position of the lumbar spine and the pelvis is closely related in the horizontal,sagittal and coronal planes.When the lumbar spine affects scoliosis and is rotated,the relative position of the pelvis will also change to compensate,which indicates that while correcting scoliosis,the correction of the pelvis cannot be ignored.

5.
Artículo en Chino | WPRIM | ID: wpr-973334

RESUMEN

ObjectiveTo investigate the in-brace and short-term correction of 3D-printed scoliosis orthoses. MethodsFrom July to December 2021, 36 patients with adolescent idiopathic scoliosis from Ninth People's Hospital, Shanghai Jiaotong University School of Medicine were selected to complete full-length radiographs of the spine before and immediately after wearing the orthosis. They wore the orthosis more than 20 hours a day, and took radiographs six months later. Cobb angle was calculated. They were assessed with Chinese version of the Scoliosis Research Society's outcomes instrument 22 (SRS-22) before wearing and six months follow-up. ResultsThe mean Cobb angle was (22.10±6.29)° before wearing, and it was (7.85±10.90)° immediately after wearing (t = 4.775, P < 0.01) and (14.33±0.74)° six months follow-up (t = 4.189, P < 0.01). The score of functional status of SRS-22 increased six months follow-up (Z = -2.676, P < 0.01). The Cobb angle immediately after wearing correlated with the Cobb angle six months follow-up (r = 0.826, P < 0.05). Conclusion3D-printed scoliosis orthoses can correct the scoliosis satisfactorily, in-brace and in short-term.

6.
Artículo en Chino | WPRIM | ID: wpr-973338

RESUMEN

ObjectiveTo review the classification of orthopedic insoles, common techniques of 3D printing orthopedic insoles, common materials and their application for flatfoot. MethodsLiteratures were retrieved from PubMed, Web of Science, CNKI and Wanfang Data from 2012 to 2022, and the relevant contents were summarized. ResultsA total of ten studies were finally included, from 5 countries, involving 290 participants, which published from 2019 to 2022. Orthotic insoles were classified as prefabricated, semi-custom, and custom, while custom ones were classified as traditional custom and 3D printed custom. 3D printed orthotic insoles were often made with selective laser sintering, fused deposition modeling (FDM) and PolyJet printing technologies, and commonly used materials included ethylene-vinyl acetate (EVA), polylactic acid, thermoplastic polyurethane, polyamide, and polypropylene. For flatfoot, 3D printed orthotic insoles could improve plantar pressure, relieve foot pain and the combined use of insole posting could control rearfoot valgus. Conclusion3D printed custom insoles can be made more efficiently and accurately than traditional custom insoles. The printing technologies and materials often chosen for 3D printed orthotic insoles are mainly FDM and EVA. 3D printed orthotic insoles is effective on plantar pressure, comfort and foot movement function of flatfoot.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA