Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Añadir filtros








Intervalo de año
1.
Rev. Soc. Bras. Med. Trop ; 47(1): 12-17, Jan-Feb/2014. tab, graf
Artículo en Inglés | LILACS | ID: lil-703147

RESUMEN

Introduction: Hepatitis C virus (HCV) infection is diagnosed by the presence of antibodies and is supplemented by confirmatory testing methods, such as recombinant immunoblot assay (RIBA) and HCV-RNA detection. This study aimed to evaluate the efficacy of RIBA testing to diagnose HCV infection in blood donors positive for anti-HCV antibodies. Methods: A total of 102 subjects positive for anti-HCV determined by enzyme-linked immunosorbent assay (ELISA) at the Hematology and Hemotherapy Foundation of Bahia (HEMOBA) were later assessed with new samples using the Abbott Architect anti-HCV test (Abbott Diagnostics, Wiesbaden, Germany), the RIBA III test (Chiron RIBA HCV 3.0 SIA, Chiron Corp., Emeryville, CA, USA), the polymerase chain reaction (PCR; COBAS® AMPLICOR HCV Roche Diagnostics Corp., Indianapolis, IN, USA) and line probe assay (LiPA - Siemens, Tarrytown, NY, USA) genotyping for HCV diagnosis. Results: Of these new samples, 38.2% (39/102) were positive, 57.8% (59/102) were negative and 3.9% (4/102) were indeterminate for anti-HCV; HCV-RNA was detected in 22.5% (23/102) of the samples. RIBA results were positive in 58.1% (25/43), negative in 9.3% (4/43) and indeterminate in 32.6% (14/43) of the samples. The prevailing genotypes were 1 (78.3%, 18/23), 3 (17.4%, 4/23) and 2 (4.3%, 1/23). All 14 samples with indeterminate RIBA results had undetectable viral loads (detection limit ≤50 IU/mL). Of these samples, 71.4% (10/14) were reevaluated six months later. Eighty percent (8/10) of these samples remained indeterminate by RIBA, and 20% (2/10) were negative. Conclusions: In this study, individuals with indeterminate RIBA results had no detectable HCV-RNA. .


Asunto(s)
Adulto , Femenino , Humanos , Masculino , Donantes de Sangre , Hepacivirus/genética , Anticuerpos contra la Hepatitis C/sangre , Hepatitis C/diagnóstico , ARN Viral/sangre , Ensayo de Inmunoadsorción Enzimática , Genotipo , Hepacivirus/inmunología , Immunoblotting , Reacción en Cadena de la Polimerasa , Proteínas Recombinantes , Carga Viral
2.
Mem. Inst. Oswaldo Cruz ; 107(5): 680-683, Aug. 2012. graf, tab
Artículo en Inglés | LILACS | ID: lil-643755

RESUMEN

The hepatitis C virus (HCV) can be detected in blood and other bodily fluids, such as saliva, semen and gastric juices. The aim of this study was to compare the HCV viral loads in the serum and saliva of infected patients. Twenty-nine patients with detectable HCV RNA in their serum and saliva were included in this study. The HCV viral loads were determined through quantitative real-time polymerase chain reactions. The median viral RNA levels were 5.78 log10 copies in the serum and 3.32 log10 copies in the saliva. We observed that the salivary HCV viral load was significantly lower than the viral load in the serum. Further studies are required to understand the role of saliva in the diagnosis, management and potential transmission of HCV.


Asunto(s)
Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven , Hepacivirus/aislamiento & purificación , Hepatitis C Crónica/virología , Saliva/virología , Suero/virología , Estudios de Casos y Controles , Estudios Transversales , Genotipo , Hepatitis C Crónica/sangre , Reacción en Cadena en Tiempo Real de la Polimerasa , ARN Viral/análisis , Carga Viral
3.
Artículo en Portugués | ColecionaSUS, LILACS | ID: biblio-945956

RESUMEN

INTRODUÇÃO: O diagnóstico correto da infecção pelo vírus da hepatite C (VHC) é de grande importância, já que o tratamento é altamente dispendioso e tem sérios efeitos colaterais. Os testes para a detecção dos anticorpos contra o VHC (anti-VHC) sofreram várias modificações e, atualmente, os testes de terceira geração são amplamente utilizados por terem sensibilidade e especificidade maiores. OBJETIVO: O objetivo deste estudo foi comparar dois testes automatizados para a detecção do anti-VHC por quimioliminescência, de terceira geração, disponíveis comercialmente. MÉTODOS: Foram utilizadas 67 amostras da soroteca do Laboratório Central de Saúde Pública do Estado da Bahia. Os reagentes utilizados foram os testes automatizados ARCHITECT® anti-HCV assay (Abbott Diagnostics, Wiesbaden, Alemanha), Elecsys® anti-HCV assay (Roche Diagnostics, Basileia, Suíça) e o teste confirmatório Recombinant Immunoblot Assay (RIBA) (Chiron RIBA VHC 3.0 SIA, Chiron Corporation, Emeryville, CA, EUA). RESULTADOS: Com o teste Architect anti-HCV assay foram obtidas 18 amostras positivas, 39 negativas e dez indeterminadas, enquanto que com o Elecsys anti-HCV assay, 47 amostras foram negativas e 20 positivas. Não houve amostras indeterminadas com este teste. Das dez amostras indeterminadas no Architect anti-HCV assay, cinco foram negativas pelo teste RIBA e cinco foram indeterminadas. Todas as amostras indeterminadas pelo RIBA apresentaram reatividade para a proteína c33. CONCLUSÃO: Os dois testes, quando comparados (62 amostras) entre si, tiveram uma concordância de 91,9 por cento. O Elecsys anti-HCV assay parece ser menos sensível que o Architect anti-HCV assay, em particular para a detecção da proteína c33, revelada pelo RIBA. Por outro lado, o Architect anti-HCV assay apresentou um maior número de resultados indeterminados em amostras negativas confirmadas pelo RIBA, o que sugere uma menor especificidade, quando comparado com o outro teste avaliado.


INTRODUCTION: A correct diagnosis of hepatitis C virus (HCV) infection is important because treatment is highly expensive and has severe side effects. The assays for the detection of antibodies against HCV (anti-HCV) have undergone several changes, and third-generation tests have been widely used due to their increased sensitivity and specificity. OBJECTIVE: In this study, we aimed to compare two commercially available, automated third-generation chemiluminescence tests for the detection of anti-HCV antibodies. METHODS: We analyzed 67 samples from the serum databank from the Laboratório Central de Saúde Pública do Estado da Bahia (LACEN-BA). The reagents examined were the automated ARCHITECT® anti-HCV assay (Abbott Diagnostics, Wiesbaden, Germany) and Elecsys® anti-HCV assay (Roche Diagnostics, Basel, Switzerland) tests and the confirmatory Recombinant Immunoblot Assay (RIBA) test (Chiron RIBA VHC 3.0 SIA, Chiron Corporation, Emeryville, CA, USA). RESULTS: The Architect anti-HCV assay indicated 18 positive samples, whereas 39 were negative and ten were indeterminate. The Elecsys anti-HCV assay indicated 47 negative and 20 positive samples and no indeterminate samples. Of the ten indeterminate samples indicated by the Architect anti-HCV assay, five were negative by the RIBA test and five were indeterminate. All indeterminate samples indicated by the RIBA test were reactive against the c33 protein. CONCLUSION: The agreement between the two tests (62 samples) was 91.9 per cent. The Elecsys anti-HCV assay appears to be less sensitive than the Architect anti-HCV, particularly for the detection of the c33 protein shown by the RIBA test. In addition, the Architect anti-HCV assay indicated more indeterminate results out of the negative samples confirmed by the RIBA test, which suggests a lower specificity than the Elecsys anti-HCV assay..


Asunto(s)
Masculino , Femenino , Humanos , Anticuerpos contra la Hepatitis C , Hepatitis C/diagnóstico , Prueba de Laboratorio/análisis
4.
Salvador; s.n; 2008. 88 p. ilus, tab, graf.
Tesis en Portugués | LILACS | ID: lil-540679

RESUMEN

Os mecanismos da resposta imune que ocorrem na infecção pelo VHC em humanos ainda não estão totalmente esclarecidos. O objetivo deste trabalho foi caracterizar a resposta imune em doadores de sangue soropositivos para o VHC (VHC+), não virêmicos e virêmicos e comparar os resultados com aqueles observados no grupo controle de não infectados (NI). As citocinas foram dosadas no soro pelo Kit CBA (cytometric bead array; BD) e os marcadores de superfície celular foram determinados nas células mononucleares do sangue periférico por análise de citometria de fluxo. Foram observadas freqüências aumentadas de altos produtores de IL-113 e IL-B no grupo não virêmico, enquanto um aumento nas freqüências de altos produtores de IL-5, IL-10 e IL-12 foi observado no grupo virêmico. Houve um aumento seletivo na freqüência de altos produtores de IL-113 no subgrupo dos não virêmicos com teste confirmatório para o anti-VHC (R/BA) indeterminado, enquanto um aumento na freqüência de altos produtores para IL-B foi restrito ao subgrupo dos não virêmicos com RIBA positivo. Este mesmo subgrupo também apresentou além do aumento na freqüência de altos produtores para a IL-4, freqüências aumentadas de altos produtores de IL-6, IL-10 e IL-12, como no grupo virêmico. No grupo virêmico foi demonstrado um aumento dos níveis de IL-113, IL-B e TNF-a nos indivíduos com valores baixos de alanina-aminotransferases (AL T), enquanto níveis mais altos de IL-2 e IFN-y foram observados naqueles com valores elevados de AL T. Além disso, foram observados níveis aumentados de IL-6, IL-10 e IL-12 particularmente naqueles com carga viral baixa. Apesar de não haver modificações no perfil hematológico nos dois grupos estudados, níveis aumentados de células pré-NK (CD3-CD16+CD56-), diminuição das células NK maduras (CD3-CD16+CD56+) e aumento da freqüência de células T CD4+ ativadas (CD4+HLA-DR+) foram características da imunidade inata no grupo não virêmico. Apesar de ambos os grupos, virêmico e não virêmico, apresentarem altos percentuais de células NK CD56 Brigh esta população foi particularmente mais elevada no subgrupo dos virêmicos com carga viral baixa. O aumento do percentual de células B (CD19+) e de células CD19+CDB6+ foram as principais características do grupo virêmico, especialmente naqueles apresentando carga viral baixa. Apesar das células CD4+CD25High estarem elevadas em ambos os grupos VHC+, o aumento desta subpopulação de células T regulatórias (Treg) foi predominantemente observado no grupo virêmico que apresentava baixa carga viral. Nossos resultados sugerem que as citocinas pró-inflamatórias (IL-II3/IL-8/TNF -a), relacionadas principalmente com a resposta imune inata, estejam associadas com o início da infecção pelo VHC ou com uma infecção menos grave, enquanto as citocinas IL-2 e IFN-y, associadas com o perfil de imunidade adaptativa citotóxica, devem estar mais ligadas com o aumento de AL T, biomarcador de lesão hepática. Além disso, as células NK CD56 Bright, juntamente com as células pré-NK e células TCD4+ ativadas em paralelo com as células T regulatórias, podem ter um papel importante no controle da viremia na infecção pelo VHC. O aumento das respostas de células NK CD56Bright e de células B em paralelo com as células T regulatórias parece estar associada com a baixa carga viral.


Asunto(s)
Humanos , Donantes de Sangre , Citocinas , Hepacivirus/inmunología , Hepatitis C/inmunología , Anticuerpos contra la Hepatitis C/inmunología , Linfocitos B , Inmunidad Celular , Células Asesinas Naturales , Linfocitos T
5.
Rev. Soc. Bras. Med. Trop ; 39(6): 567-569, nov.-dez. 2006. tab
Artículo en Portugués | LILACS | ID: lil-447291

RESUMEN

É descrito o primeiro caso de detecção do genótipo 4 do vírus da hepatite C (VHC) em Salvador, BA. Foram utilizados os testes de RT-PCR para detecção do VHC-RNA, e o LIPA para genotipagem. O genótipo 4 responde mal ao tratamento, sendo portanto importante a busca ativa dos contactantes.


The first detected case of genotype 4 of the hepatitis C virus (HCV) in Salvador, Bahia, is described. RT-PCR tests were used to detect HCV-RNA, and LIPA was used for genotyping. Genotype 4 responds poorly to treatment, and it is therefore important to actively search for people who have been in contact with it.


Asunto(s)
Humanos , Masculino , Adulto , Hepacivirus/genética , Hepatitis C/virología , ARN Viral/análisis , Genotipo , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA