Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Añadir filtros








Intervalo de año
1.
Chinese Journal of Urology ; (12): 111-115, 2022.
Artículo en Chino | WPRIM | ID: wpr-933173

RESUMEN

Objective:To investigate the feasibility and accuracy of transperineal prostate targeted biopsy guided by holographic image.Methods:Clinical data of 10 patients with transperineal prostate targeted biopsy guided by holographic image in Peking University Shougang Hospital between May and September 2020 were analyzed retrospectively. The average age was (70.9±10.3) years old, the median PSA was 15.1(6.02-1110.14) ng/ml, prostate MRI were performed before biopsy and the PI-RADS scores were all ≥ 3, and the number of suspicious target lesions was 1.4±0.5. CT examinations of urinary system were performed on the premise of mild lithotomy position and positioning stickers pasted on the skin of perineum and lower abdomen. The original data of CT and MRI were obtained, holographic image models were firstly made separately and then fused into a complete model, and the puncture paths were planned for the target lesions. At the time of puncture, the patient took the same body position as in CT scan, the operator wore a mixed reality head mounted display (HoloLens glasses), and the skin positioning stickers were used for visual registration between the holographic model and the real human body. Then under the guidance of the virtual puncture path, the puncture biopsy gun was placed, fired after reaching the predetermined depth, a transrectal ultrasound probe was placed to clarify the position of the puncture needle, and the objective accuracy of puncture was judged by comparison of ultrasound and MRI images. If the first shot was judged to be inaccurate, it was allowed to make a supplementary shot after adjusting the angle. After holographic guided biopsies, cognitive fusion targeted biopsies and 12-needle systematic biopsies were performed routinely, and the proportion of positive needles of the three different biopsy methods were calculated respectively.Results:All the 10 cases were successfully completed, including 16 holographic image guided shots, 28 cognitive fusion targeted shots and 116 systematic shots. The objective accuracy of holographic image guided biopsy after first shot judgments was 68.8% (11/16), while it raised to 87.5% (14/16) after supplementary shots. The proportion of positive needles in the three puncture methods were 56.3% (9/16), 42.9% (12/28) and 19.8% (23/116), respectively ( P=0.002). The results of subjective questionnaire showed that holographic model was helpful to improve the spatial understanding of lesions. The satisfaction of intraoperative holographic registration and guided puncture were 90% and 60%, respectively. No puncture related complication occurred in this group. Conclusion:The study preliminarily confirmed the feasibility of holographic image-guided prostate targeted biopsy. This new puncture method has better objective accuracy, and the proportion of positive needles is significantly better than systematic biopsy.

2.
Chinese Journal of Urology ; (12): 278-282, 2021.
Artículo en Chino | WPRIM | ID: wpr-885004

RESUMEN

Objective:To evaluate the clinical value of the holographic image and navigation in robotic assisted laparoscopic radical prostatectomy (RARP) .Methods:From Sept. 2020 to Dec. 2020, 5 patients diagnosed with prostate cancer in Beijing United Family Hospital were included in this study. The mean age was 57 years(38-69 years). Before the operation, the engineers established the holographic image based on the enhanced MRI images. The holographic images were used in pre-surgery planning. During the operation, the navigation was achieved by real time fusing holographic images with the robotic surgery endoscopic views. Some important structure such as prostate, bladder neck and the tumor could be observed and monitored in real time. The No.1 patient had high-risk prostate cancer, underwent RARP+ extended pelvic lymph node dissection; The No.2 patient had low-risk prostate cancer, underwent RARP, and the right side neurovascular bundle (NVB) was preserved; The No.3 patient had low-risk prostate cancer, underwent RARP, and the bilateral side NVB was preserved; The No.4 patient had low-risk prostate cancer, underwent RARP, and the right side NVB was preserved; The No.5 patient had high-risk prostate cancer, underwent RARP+ extended pelvic lymph node dissection, and the bilateral side NVB was preserved.Results:All the 5 cases surgeries were successful, no conversion to open surgery, the mean operation time was 161.7min (160-250min), the mean blood loss was 426.7 ml(60-1000 ml). The pathological results were pT 3bN 0 cM 0, pT 2aN 0 cM 0, pT 2aN 0 cM 0, pT 2aN 0 cM 0 and pT 3aN 1 cM 0, respectively. There was no over Clavien Dindo Ⅱ perioperative complications. 4 patient achieved continence when catheter removal. The PSA level and erectile function were monitored in the follow up. Conclusions:Holographic image navigation might have clinical value in RARP.

3.
Chinese Journal of Urology ; (12): 131-137, 2020.
Artículo en Chino | WPRIM | ID: wpr-869610

RESUMEN

Objective To evaluate the clinical value of holographic image navigation in urological laparoscopic and robotic surgery.Methods The data of patients were reviewed retrospectively for whom accepted holographic image navigation laparoscopic and robotic surgery from Jan.2019 to Dec.2019 in Beijing United Family Hospital and other 18 medical centers,including 78 cases of renal tumor,2 cases of bladder cancer,2 cases of adrenal gland tumor,1 cases of renal cyst,1 case of prostate cancer,1 case of sweat gland carcinoma with lymph node metastasis,1 case of pelvic metastasis after radical cystectomy.All the patients underwent operations.In the laparoscopic surgery group,there were 27 cases of partial nephrectomy,1 case of radical prostatectomy,2 cases of radical cystectomy and 2 cases of adrenalectomy.In the da Vinci robotic surgery group of 54 cases,there were 51 cases of partial nephrectomy,1 case of retroperitoneal lymph node dissection,1 case of retroperitoneal bilateral renal cyst deroofing and 1 case of resection of pelvic metastasis.There were 41 partial nephrectomy patients with available clinical data for statistic,with a median age of 53.5 years (range 24-76),including 26 males and 15 females.The median R.E.N.A.L score was 7.8 (range 4-11).Before the operation,the engineers established the holographic image based on the contrast CT images and reports.The surgeon applied the holographic image for preoperative planning.During the operation,the navigation was achieved by real time fusing holographic images with the laparoscopic surgery images in the screen.Results All the procedures had been complete uneventfully.The holographic images helped surgeon in understanding the visual three-dimension structure and relation of vessels supplying tumor or resection tissue,lymph nodes and nerves.By manipulating the holographic images extracorporeally,the fused image guide surgeons about location vessel,lymph node and other important structure and then facilitate the delicate dissection.For the 41 cases with available clinical data including 23 cases of robotic-assisted partial nephrectomy and 18 cases of laparoscopic nephrectomy,the median operation time was 140 (range 50-225) min,the median warm ischemia time was 23 (range 14-60) min,the median blood loss was 80(range 5-1 200) ml.In the robotic surgery group,the median operation time was 140 (range 50-215)min,the median warm i schemia time was 21 (range 17-40)min,the median blood loss was 150(range 30-1 200)ml.In the laparoscopic surgery group,the median operation time was 160(range 80-225)min,the median warm ischemia time was 25 (range 14-60)min,the median blood loss was 50 (range 5-1 200) ml.All the patients had no adjacent organ injury during operation.There were 2 cases with Clavien Ⅱ complications.One required transfusion and the other one suffered hematoma post-operation.However,the tumors were located in the renal hilus for these 2 cases and the R.E.N.A.L scores were both 11.Conclusions Holographic image navigation can help location and recognize important anatomic structures during the surgical procedures..This technique will reduce the tissue injury,decrease the complications and improve the success rate of surgery.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA