Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
China Pharmacist ; (12): 1693-1694, 2015.
Artículo en Chino | WPRIM | ID: wpr-670071

RESUMEN

Objective:To establish a method for the determination of Si migration in penehyclidine hydrochloride injection packed with low borosilicate glass ampoule. Methods: Si migration was determined by graphite furnace-atomic absorption spectrometry. Re-sults:The linear concentration range was 0-85 ng·ml-1(r=0. 995 6). The average recovery was 95. 85% and RSD was 4. 60% (n=9). Conclusion:The method is sensitive, rapid and accurate with good repeatability, which can be used to determine Si migration in penehyclidine hydrochloride injection packed with low borosilicate glass ampoule.

2.
China Pharmacist ; (12): 876-877, 2015.
Artículo en Chino | WPRIM | ID: wpr-669785

RESUMEN

Objective:To establish a method for the determination of antioxygen 1178 in 5-layer co-extrusion bags used for infu-sion. Methods:A Uitimat XB-C8 (250 mm × 4. 6 mm,5μm) column was used,the mobile phase was methanol-water with gradient elu-tion, the flow rate was 1. 0 ml·min-1 ,the detection wavelength was 223 nm,the column temperature was 35℃ and the injection vol-ume was 20 μl. Results:The concentration of antioxygen 1178 had the linear relationship within the range of 1. 64-205. 10 μg·ml-1 (r=0. 999 9),and the average recovery was 92. 05% (RSD=1. 94%, n=9). Conclusion:The method is accurate,stable and spe-cific,and can be used to determine antioxygen 1178 in 5-layer co-extrusion bags used for infusion.