RESUMEN
O uso da mecânica de intrusão ortodôntica, embora frequente, ainda é considerada complexa. Na busca da anulação dos efeitos reativos ou indesejáveis na intrusão dental, novas técnicas vêm sendo desenvolvidas com o objetivo de otimizar os resultados clínicos. O propósito deste artigo é apresentar a resolução de um caso de extrusão do primeiro molar superior por meio de uma mecânica de intrusão com aparelho autoligado Duplo Slot. Mecânica, essa, realizada de forma simples sem a presença de dispositivos extras, com resultado clínico satisfatório e com ausência de danos às estruturas de suporte dental.
The use of orthodontics mechanical intrusion although frequent is still considered complex. Trying to annul reactive or undesirable effects in the dental intrusion, new techniques have been developed in order to optimize the clinical results. The purpose of this article is to report the resolution of a first molar maxillary extrusion case through mechanical intrusion, using Double Slot self-ligating appliance. This mechanics was performed in a simple way, without the presence of extra devices, with satisfactory clinical results and absence of the tooth support structures damage.
Asunto(s)
Humanos , Masculino , Adulto Joven , Maloclusión , Técnicas de Movimiento Dental , OrtodonciaRESUMEN
Atualmente os bráquetes autoligados estão se tornando cada vez mais comuns nos tratamentos ortodônticos devido às inúmeras vantagens proporcionadas por estes. Hoje a movimentação dentária é realizada com bráquetes passivos ou com interativos, sendo que cada sistema apresenta suas vantagens individuais em determinadas etapas do tratamento. A proposta deste trabalho foi apresentar um novo bráquete ortodôntico autoligado, o qual visa proporcionar inúmeras movimentações dentárias de forma simples e eficiente aproveitando a técnica que o ortodontista domina, pois esta filosofia de tratamento agrega inúmeros conceitos em uma única peça.
Self-ligating brackets are becoming more common in orthodontic treatments due to numerous advantages offered by them. Currently tooth movement can be performed with passive or interactive brackets, and each system has its advantages in certain stages of treatment. The purpose of this study was to introduce a new self-ligating orthodontic bracket that aims to provide several dental movements in a simple and efficient way, leveraging the knowledge of the professional on its technique, since this philosophy of treatment combines many concepts in one piece.
Asunto(s)
Soportes Ortodóncicos , OrtodonciaRESUMEN
Os dispositivos de ancoragem temporária estão na vanguarda da Ortodontia moderna facilitando movimentos difíceis de serem conseguidos pela Ortodontia convencional, dentre eles a intrusão. Este trabalho apresenta um caso clínico, no qual foi realizada a intrusão de um molar superior utilizando mini-implante com cabeça de bráquete e sistema de ancoragem indireta
The temporary anchorage devices are at the fore front of modern orthodontics facilitating difficult movements to be reached by conventional orthodontics, including the intrusion. This paper presentes a clinical case in which was performed an upper molar intrusion using head bracket mini-implants as anchorage indirect system.
Asunto(s)
Humanos , Masculino , Adulto , Diente Molar , Técnicas de Movimiento DentalRESUMEN
O objetivo do estudo foi comparar a eficiência e o desempenho de bráquetes frente ao movimento de rotação. O método utilizou bráquetes convencionais Ovation® (GAC, Bohemia, NY, USA) ligados por amarrilho metálico e por ligante elastomérico, bráquetes autoligantes interativos In-Ovation R® (GAC, Bohemia, NY, USA) e bráquetes autoligantes passivos Damon 2® (ORMCO, Orange, CA, USA). Para padronizar o experimento foi criado um simulador de movimento dentário rotacional, composto por três pinos metálicos, dois fixos e um móvel, imersos em cera, aos quais foram encaixados corpos de prova com os bráquetes. O pino móvel foi rotacionado 30 graus. A simulação da correção da rotação dentária foi realizada com o fio 0,016 NiTi e na sequência com o fio 0,018 NiTi. As amostras foram testadas individualmente com temperatura externa constante e de forma idêntica, repetindo 10 vezes para cada amostra, registrando a quantidade de rotação em relação ao tempo. Os resultados foram tratados, estatisticamente, através da análise de variância, utilizando delineamento em medidas repetidas, complementado pelo Teste de Comparações Múltiplas de Tukey ao nível de significância de 5%. Os resultados demonstram maior controle e eficiência na correção da rotação dentária através dos bráquetes autoligantes em comparação com os convencionais. Entre os autoligantes, o resultado foi melhor com o sistema interativo, sendo que nos bráquetes convencionais com ligante elastomérico obteve-se a menor correção angular, considerando o mesmo espaço de tempo. Os acessórios autoligantes mostram a grande vantagem de um sistema de baixo atrito e com excelente gerenciamento no controle do movimento.
This study compared brackets efficiency and performance regarding rotational movements. Therefore, conventional Ovation® (GAC, Bohemia, NY, USA), brackets with archwires attached by both elastomeric and metallic ligatures, interactive self ligating In-Ovation R® (GAC, Bohemia, NY, USA) and passive self ligating Damon 2® (ORMCO, Orange, CA, USA) were used. To standardize the experiment a simulator of rotational, composed dental movement was created for three metallic bolts, two fixtures and furniture, immersed in wax, which had been incased bodies of test with the different types of brackets. The mobile bolt was rotational 30 degrees. The simulation of the correction of the dental rotation was carried through initially with the wire 0,016 NiTi and in the sequence with the 0,018 wire NiTi. The samples had been tested individually with constant external temperature and of identical form, being that the tests had been repeated 10 times for each sample, with the amount of rotation in registered relation to the time. The harvested results had been dealt with statistical through the analysis variance using the delineation in repeated measures, complemented for the Test of Multiple Comparisons of Tukey to the level of significance of 5%. The results of the study demonstrate greater have controlled and efficiency in the correction of the dental rotation through brackets self ligating, in the comparison with the conventional. Between the self ligating, the result was better with the interactive system, being that in brackets conventional with elastomeric ligating it was gotten lesser angular correction, considering the same time space. These results demonstrated the advantages of a system that works due to friction control that brings a better control over the dental movement.
Asunto(s)
Técnicas de Movimiento Dental , Aparatos Ortodóncicos , Soportes OrtodóncicosRESUMEN
Este estudo teve como objetivo comparar diferentes tipos de sistemas de bráquetes com seus diferentes sistemas de ligações, quanto à eficiência no controle do movimento de terceira ordem, o torque. Foram analisados 4 grupos (n=10): Ligação Passiva - com o bráquete autoligante Damon® 3MX(Ormco, Orange, California, EUA); Ligação Interativa - com o bráquete autoligante In-Ovation® R(GAC, Bohemia, NI, EUA) e Ligação Elástica e Metálica com bráquete convencional Ovation® (GAC, Bohemia, NI, EUA). Foi desenvolvido um dispositivo que simula um tratamento ortodôntico a partir da utilização de uma sequência de fios ortodônticos (0,017x0,025; 0,018x0,025; 0,019x0,025; 0,021x0,025), medindo a evolução do movimento de torque em graus. Utilizando o fio 0,017x0,025, o grupo Ligação Passiva apresentou 0% de correção, o grupo Ligação Interativa 76,82%, o grupo Ligação Metálica mostrou 86,36% e o grupo Ligação Elástica 51,36% de correção do torque. Colocando o fio 0,018x0,025, o grupo Ligação Passiva passou apresentar 1,11% de correção, o grupo Ligação Interativa 92,73%, o grupo Ligação Metálica 95,45% e o grupo Ligação Elástica 71,82% de correção do torque. Posicionando o fio 0,019x0,025, o grupo Ligação Passiva apresentou 30,56% de correção, Ligação Interativa com 100%, Ligação Metálica com 100% de e o grupo Ligação Elástica 85,45% de correção do torque. Finalmente, fixando o fio 0,021x0,025, o grupo Ligação Passiva resultou em 63,33% de correção, Ligação Interativa 100%, Ligação Metálica 100% e o grupo Ligação Elástica 95,45% de correção do torque. Conclui-se que os grupos Ligação Interativa e Ligação Metálica apresentaram as maiores porcentagens de correção do torque, atingindo a totalidade da prescrição incorporada ao bráquete com o fio 0,019x0,025. Os grupos Ligação Passiva e ligação elástica apresentaram porcentagens de correção de torque aquém da prescrição, mesmo com o fio 0,021x0,025
The aim of this study was to compare different types of bracket systems with their different ligation systems related to efficiency in controlling the third order movement, torque. Four groups were analyzed (n=10): Passive Ligation - with self-ligating bracket Damon® 3MX (Ormco, Orange, California, USA); Interactive Ligation - with self-ligating bracket In-Ovation® R (GAC, Bohemia, NY, USA), and Elastic and Metallic Ligation - with conventional bracket Ovation® (GAC, Bohemia, NY, USA). A device was developed to simulate an orthodontic treatment from the use of a sequence of orthodontic wires (0.017x0.025; 0.018x0.025; 0.019x0.025; 0.021x0.025), measuring the torque motion evolution in degrees. Using Wireless 0.017 x0.025 Passive Ligation group had 0% correct, the group presented Interactive Ligation 76.82% accuracy, the group presented the Metal Ligation 86.36% and the group Elastic Ligation 51.36 % correction of torque. Placing the wire 0.018 x0.025 Passive Ligation group showed 1.11% accuracy, the Interactive Ligation 92.73%, the Metal Ligation 95.45% and the group Elastic Ligation 71,82% correction of torque. Positioning the wire 0.019 x0.025 Passive Ligation group showed 30.56% accuracy, the Interactive Ligation with 100%, the Metal Ligation with 100% and the group Elastic Ligation 85.45% of correction of torque. Finally, setting the thread 0.021 x0.025 Passive Ligation group showed 63.33% accuracy, the Interactive Ligation with 100%, the Metal Ligation with 100% and the group Elastic Ligation 95.45 % correction of torque. The self-ligating bracket with Interactive Ligation and the conventional bracket with Metallic Ligation had higher percentages of correct torque. The self-ligating bracket with Passive Ligation had the lowest percentages of correct torque. The conventional bracket with Elastic Ligation developed percentages of correct torque that can be considered satisfactory.