Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Journal of Southern Medical University ; (12): 107-110, 2021.
Artículo en Chino | WPRIM | ID: wpr-880835

RESUMEN

OBJECTIVE@#To investigate accuracy of the currently used strategies for intraocular pressure measurements for reflecting actual 24-hour intraocular pressure fluctuations.@*METHODS@#From September, 2018 to January, 2019, the patients with a suspected diagnosis of primary open angle glaucoma at our hospital were prospectively enrolled to receive 24-hour intraocular pressure monitoring using a Goldmann tonometer. With the intraocular pressure measurements at 0:00, 2:00, 5:00, 7:00, 8:00, 10:00, 11:00, 14:00, 16:00, 18:00, 20:00, and 22:00 as the gold standard (strategy 1), we compared the measurements taken at 5:00, 7:00, 10:00, 14:00, 18:00, and 22:00 (strategy 2) and at 8:00, 11:00, 14:00, and 16:00 (strategy 3) for their accuracy in reflecting 24-h intraocular pressure fluctuations.@*RESULTS@#A total of 41 patients (82 eyes) were enrolled in this study. The peak intraocular pressures measured using the 3 strategies were 21.09±4.15 mmHg, 20.54±4.10 mmHg, and 19.91±4.38 mmHg, respectively, showing significant differences among them (@*CONCLUSIONS@#For suspected cases of glaucoma, intraocular pressure measurements at 4 and 6 time points of a day can not precisely reflect the actual range of intraocular pressure fluctuations, and may lead to a missed diagnosis of glaucoma.


Asunto(s)
Humanos , Glaucoma/diagnóstico , Glaucoma de Ángulo Abierto , Presión Intraocular , Estudios Prospectivos , Tonometría Ocular
2.
International Eye Science ; (12): 915-918, 2018.
Artículo en Chino | WPRIM | ID: wpr-695340

RESUMEN

AIM: To analyze the value of 24 - hour intraocular pressure ( IOP) monitoring in suspected glaucoma patients. METHODS: Totally 48 suspected glaucoma (96 eyes) were selected for 24 - hour IOP monitoring by using Accupen tonometer (24 - 3000) and non - contact tonometer (NCT, CT-80A) from 9 30 to 7 30 next day (once in 2h). During 07 30 to 21 30, patients were measured in sitting position,while during 23 30 to 05 30 in both sitting and supine position. RESULTS:A morning peak of IOP was shown at 7 30 in traditional position by using two measures with 22.05士3 608mmHg of NCT and 19.79士4.147mmHg of Accupen tonometer. The peak IOP in habitual position appeared in 5 30 with 21.64士4.814mmHg. The lowest IOP occurred in both position at 21 30 with 15. 73士3. 649mmHg. Both positions showed IOP trend of going up at night and then declining in the morning. CONCLUSION: The peak IOP in suspected glaucoma occurs mostly at early morning. Supine IOP of sleeping time is higher than that of sitting position.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA