Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Artículo en Chino | WPRIM | ID: wpr-1020538

RESUMEN

Objective:To retrospectively evaluate the clinical outcomes of autonomous dental implant robot(ADIR)assisted implant surgery in 1-year follow-up.Methods:20 patients with tooth missing underwent implantation surgery by ADIR were incuded.The plat-form deviation,apex deviation and angular deviation of the implants were analyzed.The marginal bone height and peri-implant soft tis-sue health were measured and observed immediately,6 months and 12 months after the restoration.Results:The platform deviation,apex deviation and angular deviation of 20 implants at the 3 follow-up examinations were(0.34±0.11)mm,(0.34±0.15)mm and(0.82°±0.38°),respectively.There was no significant difference in the accuracy of different implant diameter and length(P>0.05).During the follow-up period,all implants had successful osseointegration,stable marginal bone height,and acceptable peri-implant soft tissue condition.Conclusion:The 1-year follow-up indicates that ADIR can achieve promising clinical performance.Long-term follow-up studies are still necessary for verification.

2.
Artículo en Chino | WPRIM | ID: wpr-460696

RESUMEN

Objective To evaluate the precision and accuracy of blood glucose meter(BGM ) for community home use testing . Methods According to the In Vitro Diagnostic Test Systems‐Requirements for Blood Glucose Monitoring Systems for Self‐Testing in Managing Diabetes Mellitus in DIN EN ISO15197 :2013 .Capillary blood and venous blood were tested by BGM and the laborato‐ry biochemical analyzer respectively .The measurement results of each BGM were compared with the results of the biochemical ana‐lyzer for conducting the bias analysis .Results In evaluated 20 BGM ,none of them met the requirements of ISO15197 :2013(when blood glucose concentrations < 5 .5 mmol/L ,the bias in 95% of detection results is within the range of ± 0 .83 mmol/L ;when blood glucose concentrations ≥ 5 .5 mmol/L ,the bias in 95% of detection results is within the range of ± 15% .Only 11 imported BGM (55% ) met the state standard .Conclusion The bias of 20 BGM ranged - 28 .7% - 3 .8% ,with the average bias of - 12 .2% . These detection results will bring the large risk of therapy in the diabetic patients .The regular and standardized evaluation of BGM performance may ensure the quality of blood glucose self - monitoring .

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA