Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Rev. bras. ortop ; 56(1): 98-103, Jan.-Feb. 2021. tab
Artículo en Inglés | LILACS | ID: biblio-1288649

RESUMEN

Abstract Objectives The present study evaluates and compares the surgical treatment of acute and chronic acromioclavicular dislocations (ACDs) to define the most effective therapeutic plan. Methods A retrospective study consisting of 30 patients submitted to the surgical treatment of types III and V ACDs between 2011 and 2018; the subjects were separated according to a temporal classification in acute (< 3 weeks; subgroup I) and chronic (> 3 weeks; subgroup II) subgroups. All patients underwent a postsurgical evaluation with a standardized protocol containing epidemiological, functional, and radiological data. Results Subgroup I presented a visual analog scale (VAS) score of 1.10, a Constant-Murley score of 92.3, and a University of California at Los Angeles (UCLA) Shoulder Rating score of 33.5. The coracoclavicular (CC) distance was of 11.0 mm, and the average increase in CC space was lower than 8.9% compared to the contralateral shoulder. In subgroup II, the VAS score was of 1.11, the Constant-Murley score was of 94.2, and the UCLA score was of 32.4. The CC distance was of 13.8 mm, with a 22.9% increase in CC space compared to the contralateral side. Conclusion Although there was no significant difference between the evaluated items, subgroup I tended to present a lower CC distance (p = 0.098) and a lower percentage increase in CC distance (p = 0.095) compared to subgroup II. Thus, the surgical treatment must be performed within three weeks after the trauma to try to avoid such trend. If the acute treatment is not possible, the modified Weaver Dunn technique has good clinical and functional outcomes.


Resumo Objetivos Avaliar e comparar os resultados do tratamento cirúrgico das luxações acromioclaviculares (LACs) aguda e crônica, definindo o plano terapêutico mais eficaz. Métodos Estudo retrospectivo realizado com 30 pacientes operados entre 2011 e 2018 para LAC tipos III e V, separados de acordo com a classificação temporal em subgrupo agudo (< 3 semanas; subgrupo I) e subgrupo crônico (> 3 semanas; subgrupo II). Todos os pacientes foram submetidos a avaliação pós-cirúrgica com protocolo padronizado composto por dados epidemiológicos, funcionais e radiográficos. Resultados No subgrupo I, a pontuação na escala visual analógica (EVA) foi de 1,10, o escore de Constant-Murley foi de 92,3, e o escore da University of California at Los Angeles (UCLA) foi de 33,5. A distância coracoclavicular (CC) foi de 11,0 mm, e o aumento do espaço CC foi em média menor do que 8,9% em relação ao ombro contralateral. No subgrupo II, a EVA foi de 1,11, o escore de Constant-Murley foi de 94,2, e o da UCLA, 32,4. A distância CC foi de 13,8 mm, sendo o aumento do espaço CC de 22,9% em relação ao contralateral. Conclusão Apesar de não ter havido diferença significativa entre os quesitos avaliados, houve uma tendência de o subgrupo agudo apresentar distância CC (p = 0,098) e percentual de aumento da distância CC (p = 0,095) menor do que o subgrupo crônico. Assim, é interessante que o tratamento cirúrgico seja realizado nas primeiras três semanas após o trauma, para tentar evitar essa tendência. Nos casos em que não for possível realizar o tratamento na fase aguda, a técnica de Weaver Dunn modificada apresenta bons resultados clínicos e funcionais.


Asunto(s)
Humanos , Articulación Acromioclavicular/cirugía , Articulación Acromioclavicular/lesiones , Luxaciones Articulares , Ligamentos Articulares
2.
Rev. bras. ortop ; 54(3): 247-252, May-June 2019. graf
Artículo en Inglés | LILACS | ID: biblio-1013724

RESUMEN

Abstract Objective To evaluate the mechanical properties of sutures commonly used in orthopedic surgeries, characterizing their behavior through tensile tests and determining which one has greater mechanical strength. Method Tensile tests of different sutures were performed in a mechanical testing machine BME 10 kN, using a 50 kgf maximum capacity loading cell. Seven samples from each suture material were tested. Both ends of the sample material were fixed in the proper metal claw, maintaining an initial length of 5 cm. Tests were performed at a speed of 20 mm/minute and at room temperature, recording data for maximum displacement and maximum force at the rupture point. Results FiberWire® #2 (Artrhex, Naples, FL, USA) presented the highest mean strength of rupture (240.17 N), followed by HiFi® #2 (Conmed, Utica, NY, USA) (213.39N) and Ethibond® #5 (Ethicon Inc., Somerville, NJ, USA) (207.38 N). Ethibond® #2 (Ethicon Inc., Somerville, NJ, USA) had the lowestmean strength of rupture (97.8 N). Conclusion Non-absorbable braided polyblend sutures, more recently introduced, are superior to conventional, braided polyester sutures, and FiberWire® #2 is the most resistant suture evaluated in the present study.


Resumo Objetivo Avaliar as propriedades mecânicas dos fios de sutura normalmente usados nas cirurgias ortopédicas e caracterizar seu comportamento por meio de ensaios de tração para verificar qual deles apresenta maior resistência mecânica. Método Os ensaios de tração dos diferentes tipos de fios de sutura foram feitos na máquina de ensaios mecânicos BME 10 kN, comcélula de carga de capacidademáxima de 50 kgf. Foram ensaiadas sete amostras de cada tipo de fio de sutura, foram fixadas cada uma das extremidades da amostra na garra metálica própria para o ensaio de fios e manteve-se o comprimento inicial de 5 cm. Os ensaios foram feitos com uma velocidade de 20 mm/minuto e à temperatura ambiente, registraram-se os dados de força máxima e o deslocamento máximo na ruptura dos fios. Resultados A força média de rupturamais elevada foi observada na sutura FiberWire® 2 (Artrhex, Naples, FL, EUA) (240,17 N), seguida pela HiFi® 2 (Conmed, Utica, NY, EUA) (213,39 N) e Ethibond® 5 (Ethicon Inc., Somerville, NJ, EUA) (207,38 N). A menor força média de ruptura foi obtida para o fio Ethibond® 2 (Ethicon Inc., Somerville, NJ, EUA) (97,8 N). Conclusão Os fios de sutura não absorvíveis de polimistura trançada, de surgimento mais recente, são superiores ao fio de sutura convencional de poliéster trançado. O FiberWire® 2 é o mais resistente dos fios avaliados no presente estudo.


Asunto(s)
Hombro , Suturas , Fenómenos Biomecánicos , Articulación Acromioclavicular/cirugía , Articulación Acromioclavicular/lesiones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA