Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Braz. dent. sci ; 26(3): 1-9, 2023. ilus, tab
Artículo en Inglés | LILACS, BBO | ID: biblio-1442902

RESUMEN

Objective: This study aims to compare the strain induced in the supporting structures of unilateral mandibular removable partial denture frameworks retained by extra-coronal attachments fabricated with three different materials. Material and Methods: Three mandibular class II digitally designed and printed acrylic models with detachable abutments were used to fabricate three removable partial denture framework with extra coronal attachments from three different materials. A total of 33 models were prepared for strain testing (n=11). Models were divided into three groups according to framework's material: porcelain fused to cobalt chromium (PFM), polyetherketoneketone (PEKK) and polyetheretherketone (PEEK) group. Unilateral load of 60 N was applied in the three groups and strains were measured around the main abutment and saddle area using strain gauge. Results: Statistical analysis was performed using Shapiro-Wilk's test and by checking data distribution. Data were found to be non-parametric and were analysed using Kruskal-Wallis test followed by Dunn's post hoc test with Bonferroni correction. PFM group showed significantly the highest strain values around abutment, slot 1 (1mm distal to the socket of the last abutment) and slot 2 (1 cm away from slot 1) respectively (843.00±23.08, 91.00±6.52 and 1274.00±65.71) than the other tested groups (p<0.05) at same tested sites respectively followed by PEKK group (384.00±37.48, 81.00±2.24 and 135.00±0.00) and PEEK group (29.00±4.18, 63.00±4.47 and 52.00±5.70). Conclusions: PEEK and PEKK for partial denture framework with extra coronal attachments are adequate alternative to PFM due to their good mechanical response applying less strain on supportive structures in free-end cases. PEEK induces lower strain magnitude on the supporting structures when compared to PEKK. (AU)


Objetivo: Este estudo tem como objetivo comparar a tensão induzida nas estruturas de suporte de estruturas de próteses parciais removíveis mandibulares unilateraisretidas por encaixes extracoronários fabricados com três materiais diferentes. Material e Métodos: Três modelos mandibulares de classe II digitalmente projetados e impressos em acrílico com pilares destacáveis foram usados para fabricar três estruturas de próteses parciais removíveis com encaixes extracoronários de três materiais diferentes. Um total de 33 modelos foram preparados para testes de deformação (n=11). Os modelos foram divididos em três grupos de acordo com o material da estrutura: porcelana fundida com cobalto-cromo (PFM), poliétercetonacetona (PEKK) e polieteretercetona (PEEK). Carga unilateral de 60 N foi aplicada nos três grupos e as deformações foram medidas em torno do pilar principal e área de sela usando medido de tensão. Resultados: A análise estatística foi realizada por meio do teste de Shapiro-Wilk e com a verificação da distribuição dos dados. Os dados mostraram-se não paramétricos e foram analisados pelo teste de Kruskal-Wallis seguido pelo de Dunn com correção de Bonferroni. O grupo PFM mostrou significativamente os maiores valores de tensão ao redor do pilar, slot 1 (1mm distal do último pilar) e slot 2 (1 cm de distância do slot 1) respectivamente (843,00±23,08, 91,00±6,52 e 1274,00±65,71) do que os outros grupos testados (p<0,05) nos mesmos locais testados, respectivamente, seguido pelo grupo PEKK (384,00±37,48, 81,00±2,24 e 135,00±0,00) e grupo PEEK (29,00±4,18, 63,00±4,47 e 52,00±5,70). Conclusão: PEEK e PEKK para estrutura de prótese parcial com encaixes extracoronários são alternativas adequadas ao PFM devido à sua boa resposta mecânica aplicando menos tensão nas estruturas de suporte em casos de extremidade livre. O PEEK induz menor magnitude de deformação nas estruturas de suporte quando comparado ao PEKK (AU)


Asunto(s)
Dentadura Parcial , Dentadura Parcial Removible , Ajuste de Precisión de Prótesis
2.
Acta odontol. latinoam ; 25(1): 114-121, 2012. ilus, graf, tab
Artículo en Inglés | LILACS | ID: biblio-949676

RESUMEN

The aim of this study was to evaluate the polymerization stress and degree of conversion of a composite submitted to different photoactivation protocols. The composite Filtek Z350 was placed in the central perforation of a photoelastic disc and polymerized using a LED-based curing unit (BluePhase II - IvoclarVivadent) with energy density of 12, 24 or 36 J/cm² using the following photopolymerization protocols: continuous high intensity (HI: 1200 mW/cm² during 10, 20 or 30s), continuous low intensity (LI: 650 mW/cm² during 18, 36 or 54s) and soft-start (SS: 150 mW/cm² during 5 s + 1200 mW/cm² during 9, 19 or 29s) (n=5). Photoelastic analysis was used to evaluate polymerization shrinkage stress and FTIR was performed to determine the degree of conversion of the composite. ANOVA 3-way procedure was used to determine the significance of the main effects and their interactions followed by two-way ANOVA for each time was performed (p<0.05). Shrinkage stress increased with higher values of energy. No statistically significant differences on polymerization shrinkage stress were found between high and low intensity activation modes. Softstart method generated stresses that were statistically lower than continuous modes except when 12 J/cm² was applied. Similar degree of conversion was observed for photoactivation modes used, except for soft-start mode with 12, 24 and 36 J/cm² that showed lowest levels of conversion. Energy density and activation mode influenced polymerization shrinkage stress, but no benefit on degree of conversion was observed.


O objetivo neste estudo foi avaliar a tensão de contração de polimerização e o grau de conversão de uma resina composta submetida a vários protocolos de fotoativação. O compósito Filtek Z350 foi inserido na perfuração central de um disco de resina fotoelástica e polimerizado usando uma unidade de fotoativação LED (BluePhase II - IvoclarVivadent) com as doses de energia de 12, 24 or 36 J/cm² usando os seguintes protocolos de polimerização: contínuo de alta intensidade (HI: 1200 mW/cm² durante 10, 20 ou 30s), contínuo de baixa intensidade (LI: 650 mW/cm² durante 18, 36 ou54s) e "soft-start" (SS: 150 mW/cm² durante 5 s + 1200 mW/cm² durante 9, 19 ou 29s) (n=5). Análise fotoelástica e Espectroscopia Infravermelha Transformada de Fourier (FTIR) foram usados para avaliar a tensão de contração de polimerização e grau de conversão do compósito respectivamente. O teste ANOVA três fatores foi usado para determinar os principais efeitos e interações das variáveis e seguidamente, ANOVA 2 fatores para ver a diferença entre os grupos (p<0.05). A tensão de contração aumentou com valores maiores de energia. Não foram observadas diferenças estatisticamente significantes para a tensão de contração entre os modos de alta e baixa intensidade. O modo "soft-start" gerou menor tensão que os modos contínuos, exceto quando 12 J/cm² foi aplicado. Similar grau de conversão foi observado para os modos de fotoativação usados, com exceção do modo "soft-start" com 12, 24 e 36 J/cm² que mostraram níveis menores de conversão. A dose de energia e modo de ativação influenciam a tensão de contração de polimerização, porém nenhum benefício no grau de conversão foi observado.


Asunto(s)
Resinas Compuestas , Ensayo de Materiales , Análisis del Estrés Dental , Polimerizacion , Luz
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA