Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Añadir filtros








Intervalo de año
1.
Chinese Journal of Primary Medicine and Pharmacy ; (12): 1154-1159, 2023.
Artículo en Chino | WPRIM | ID: wpr-991877

RESUMEN

Objective:To investigate the role of serum CX3CR1 in the diagnosis of coronary artery stenosis and in the evaluation of prognosis after percutaneous coronary intervention.Methods:A total of 101 patients with coronary artery stenosis (≥ 50% stenosis) confirmed with coronary angiography (CAG) in Haiyang People's Hospital from January 2018 to May 2019 who were followed up till May 2021 were included in the observation group. Thirty-four healthy individuals who underwent physical examination during the same period were included in the control group. Patients in the observation group were divided into an in-stent restenosis group (ISR group, n = 28) and a non-ISR group ( n = 73). The expression of CX3CR1 was detected. The incidence of adverse cardiac events was calculated. The sensitivity, specificity, and area under the curve (AUC) plotted for the use of CX3CR1 to diagnose coronary artery stenosis and predict adverse cardiac events were evaluated. Results:The expression of CX3CR1 in the observation group was (3.95 ± 1.05) μg/L, which was significantly higher than (2.30 ± 0.65) μg/L in the control group ( t = 2.87, P < 0.05). The receiver operating characteristic curve analysis showed that the AUC, sensitivity, and specificity of the use of CX3CR1 in diagnosing coronary artery stenosis were 0.892, 75.2%, and 88.2%. The incidence of non-fatal myocardial infarction, angina pectoris, heart failure, and cardiac death in the ISR group was significantly higher compared with the non-ISR group ( χ2 = 8.06, 7.17, 8.06, 7.17, all P < 0.05). The receiver operating characteristic curve analysis results showed that the AUC value of CX3CR1 in predicting non-fatal myocardial infarction, angina pectoris, heart failure, and cardiac death were 0.786, 0.895, 0.997, and 0.887, respectively. Conclusion:CX3CR1 is highly expressed in coronary artery stenosis, which can provide a reference for the diagnosis and prognostic evaluation of coronary artery stenosis.

2.
The Journal of Practical Medicine ; (24): 4160-4164, 2017.
Artículo en Chino | WPRIM | ID: wpr-665283

RESUMEN

Objective To investigate the diagnostic value of High-Sensitive Troponin T(hs-TnT)in acute myocardial infarction(AMI). Methods One hundred and sixty nine patients with serum hs-TnT concentration≥0.014 μg/L in early hospitalization were enrolled in this study.The ROC curve was used to compare the concentra-tion of hs-TnT with four heart enzyme(CK,CK-MB,LDH,AST)on the diagnostic efficacy to AMI. The differ-ence of hs-TnT in different clinical data groups were investigated using Mann-Whitney U rank test.Then the correla-tion between hs-TnT and Gensini score of Coronary angiography was investigated using the Spearman rank correla-tion test.Results The concentration of hs-TnT in patients with chest pain was significantly higher than that in non-AMI group(P<0.05).The AUC of each ROC curve was hs-TnT(0.806)>CK-MB(0.792)>CK(0.780)>AST (0.704)> LDH(0.684). The optimal diagnostic point of hs-TnT was 0.152 ug/L(sensitivity 0.659,specificity 0.894,Yuden index 0.553).There was a positive correlation between hs-TnT and Gensini scores in men,age>65 years old and the chest tightness group(P < 0.05). Conclusion The hs-TnT is better than four heart enzyme in early diagnosis of AMI and benefit early treatment of AMI.

3.
Tianjin Medical Journal ; (12): 1056-1058,1059, 2015.
Artículo en Chino | WPRIM | ID: wpr-602776

RESUMEN

Objective To evaluation the anatomy relationship between thoracic artery and coronary artery by using 256 layer spiral CT angiography. Methods The angiographic images of thoracic aortic and coronary artery angiography were re?vealed in 200 patients with chest pain. Values of the major branch length, diameter, length of the aorta-coronary artery by?pass on both sides of the thoracic artery and coronary artery were measured. Results The diameter of thoracic artery was (2.52±0.38) mm, and the length of thoracic artery from the starting point to terminal was (190.12 ±1.90) mm. There were no significant differences in the thoracic artery lumen diameter and length between both sides. The inner diameters of left anteri?or descending coronary artery, left circumflex, diagonal branch, right coronary artery and the posterior interventricular branch were (2.82 ±0.25), (2.60±0.12), (2.22±0.25), (3.02±0.27) and (2.35±0.35) mm respectively. There were no significant differences in thoracic artery diameters except for the right coronary artery diameter, which was higher than that of the thorac?ic artery. About free transplantation the length from 2cm above in the ascending aorta starting to the halfway point of anterior descending coronary artery, to the atrioventricular node along the left circumflex way, to the atrioventricular node along the right coronary artery and from the atrioventricular node to halfway point of posterior interventricular branch was shorter than that of thoracic artery (P0.05). The length from the thoracic artery start department to the left-hand atrioventricular node, to the right coronary artery atrio?ventricular node was higher than that of the thoracic artery length (P<0.05). Conclusion The branches of internal thoracic artery and coronary artery are similar. About situ transplantation is suitable for the wall blood vessels before the heart. With free thoracic artery transplantation, its length can meet any bridging from the ascending aorta to the coronary arteries.

4.
Tianjin Medical Journal ; (12): 248-250, 2014.
Artículo en Chino | WPRIM | ID: wpr-473470

RESUMEN

Objective To observe the clinical significance and variation of plasma B-type brain natriuretic peptide (△BNP) levels before and after treadmill exercise test (TET) in women with coronary heart disease(CHD). Methods Sixty-one women with suspected coronary heart disease were selected (except for heart failure, blood BNP levels were normal). All patients underwent coronary angiography, were divided into two groups, 25 cases in normal group and 36 cases in coronary heart disease group. Plasma BNP levels were measured before and after the TET test, and data were compared between two groups after one week.Furthermore, the levels of△BNP before and after TET in patients with different degrees of coronary artery lesions were compared. The diagnostic value of the levels of△BNP in coronary heart disease was evaluated by the re-ceiver operating characteristic curve (ROC). Results The plasma BNP level was significantly increased after TET (44.20± 14.53) than that before the test (32.82±10.72) in coronary heart disease group (P<0.01). There were significant differences in levels of△BNP before and after TET in patients with different degrees of coronary lesions. The levels of△BNP were sig-nificantly higher in multi-vessel disease group than those of single and double lesion group (P<0.05). The level of△BNP was significantly higher in double lesion group than that of single lesion group (P < 0.05). When the level of △BNP=7.3 ng/L, the sensibility value and specificity value for the diagnosis of CHD was 82.4%and 81.5%. The area under curve (AUC) was 0.900, and 95%confidence interval was 0.796-0.962. Conclusion The detection of△BNP before and after TET has an important clinical significance in the diagnosis and evaluation of coronary heart disease in women patients.

5.
Chinese Journal of Pathophysiology ; (12)1986.
Artículo en Chino | WPRIM | ID: wpr-524248

RESUMEN

AIM: To study the significance of expressio n of fms-like tyrosine kinase 4 (Flt-4) in different histopathological grades of a strocytoma. METHODS: The surgical specimens from 50 brain astrocytoma patien ts were stained immunohistochemically for examining Flt-4 and vascular endotheli al growth factor (VEGF) expression. Intratumoral microvessel density (IMVD) was calculated by labeling the endothelial cells of the blood vessels within the tum or. RESULTS: Flt-4, VEGF expression were closely correlated with his topathological grades of astrocytoma. Flt-4 and VEGF expression were found in 52 % (26/50), 60% (30/50) of tumors. A significant correlation was found between Fl t-4 and VEGF expression (P

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA