Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Rev. estomat. salud ; 31(1): 1-6, 20230123.
Artículo en Portugués | LILACS-Express | LILACS | ID: biblio-1435261

RESUMEN

Focal fibrous hyperplasia (FFH) is a pathology characterized by tissue enlargement as a result of increasing the number of inflammatory cells which receive chronic mechanical stimuli of low intensity that may affect gums, lip, palate, jugal mucosa and tongue.The aim of this article is to report a case of FFH on the lateral border on both sides of the tongue associated with the use of the Hyrax appliance in a hebiatric patient, whose chief complaint was chewing discomfort. This case was diagnosed clinically and by histopathology analysis and treated by surgical excision as well as the removal of Hyrax appliances. Follow-up care provided the recovery of the patient's quality of life.


La hiperplasia fibrosa focal (HFF) es una patología caracterizada por el aumento de tamaño de los tejidos como consecuencia del aumento del número de células inflamatorias que reciben estímulos mecánicos crónicos de baja intensidad que pueden afectar a encías, labio, paladar, mucosa yugal y lengua. El objetivo de este artículo es reportar un caso de FFH en el borde lateral a ambos lados de la lengua asociado al uso del aparato Hyrax en un paciente hebiátrico, cuyo principal motivo de consulta era la molestia masticatoria. Este caso fue diagnosticado clínicamente y por análisis histopatológico y tratado mediante escisión quirúrgica así como la retirada de los aparatos de Hyrax. La atención de seguimiento permitió la recuperación de la calidad de vida del paciente

2.
Rev. Fac. Odontol. Univ. Antioq ; 32(1): 18-25, June 2020. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1149597

RESUMEN

ABSTRACT Introduction: all orthodontic treatments must be safe in terms of temporomandibular joint health. No reports in the recent literature evaluate the association between the use of posterior bite turbos and condylar position changes. The aim of the present study was to evaluate condylar position changes occurring after three-month treatment with posterior bite turbo in patients from the Dental School of the Universidad del Valle. Methods: a sample of 15 hyperdivergent patients was randomly distributed into two groups: Bite Turbo and Control Group. Cone-Beam Computed Tomography (CB-CT) was used to assess the condyle position before the bite turbos bonding to first and second molars, and after three months of use of the appliances. Distances were taken from the CB-CT by a single operator, and the calibration was tested with intraclass correlation (> 0.9). Results: no statistical difference between the position of left and right condyles was detected. However, there was a significant difference in the upper space of the left condyle between the initial and final measurement. Patients reported satisfactory use of the occlusal bite turbo (85.8%) in three months of treatment. Conclusion: contrary to the expected, the simultaneous use of posterior occlusal appliances with balanced mandibular movements for 3 months did not cause significant changes in condylar position. The patients tolerate well the use of occlusal stops. Keywords: orthodontic appliance, cone-beam computed tomography, temporomandibular joint condyle, dental occlusion


RESUMEN Introducción: todos los tratamientos de ortodoncia deben ser seguros con respecto a la salud de las articulaciones temporomandibulares. La literatura reciente no reporta estudios en los que se evalúe la asociación entre el uso de topes de mordida posterior y cambios de posición condilar. El objetivo del presente estudio consistió en evaluar los cambios de posición condilar que se produjeron después de tres meses de tratamiento con tope de mordida posterior en pacientes de la Facultad de Odontología de la Universidad del Valle. Métodos: la muestra de 15 pacientes hiperdivergentes se distribuyó aleatoriamente en dos grupos: Bite Turbo y Grupo control. Se utilizó tomografía computarizada de haz de cono para evaluar la posición del cóndilo antes de la unión de los topes de mordida a los molares primero y segundo, y después de tres meses de uso de los dispositivos. Las distancias fueron tomadas en el tomógrafo por un solo operador, y la calibración se probó con correlación intraclase (> 0.9). Resultados: no se detectó ninguna diferencia estadística entre la posición de los cóndilos izquierdo y derecho. Sin embargo, hubo una diferencia significativa en el espacio superior del cóndilo izquierdo entre la medición inicial y final. Los pacientes notificaron un uso satisfactorio del bite turbo oclusal (85,8%) después de tres meses de tratamiento. Conclusión: contrario a lo que se suponía, el uso simultáneo de aparatos oclusales posteriores con movimientos mandibulares equilibrados durante 3 meses no causó cambios significativos en la posición de los cóndilos. Los pacientes toleran bien el uso de topes oclusales.


Asunto(s)
Articulación Temporomandibular , Ortodoncia , Oclusión Dental
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA