Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Añadir filtros








Intervalo de año
1.
Odovtos (En línea) ; 24(1)abr. 2022.
Artículo en Inglés | LILACS, SaludCR | ID: biblio-1386577

RESUMEN

Abstract This study evaluated the effects of alternative self-etch application modes on resin-dentin microtensile bond strength (µTBS) of three commercially available "no wait" concept universal adhesives. In this study extracted impacted non-carious human third molars were used. The flat surfaces were prepared in mid-coronal dentin and prepared with a 600-grit SiC paper. The three universal adhesives that were used are as follows: Clearfil Universal Bond Quick (CUQ, Kuraray Noritake, Japan), G-Premio Bond (GPB, GC Corp, Japan), and a self-curing universal adhesive "Tokuyama Universal Bond" (TUB; Tokuyama Dental, Japan). The following three different application procedures were used for the dentin surfaces: the adhesives were applied and immediately subjected to air-dry; the adhesives were applied followed by a 10-second wait; or the adhesives were rubbed for 10 seconds. Then composite resin was applied to the dentin surface and light cured. After storage in 37°C distilled water for 24 h, all the bonded teeth were cut into 1mm² sections using a low-speed diamond saw (Micracut 125 Low Speed Precision Cutter, Metkon, Bursa, Turkey) under running water (n=15). The sections were subjected to a tensile force at a crosshead speed of 1mm/min in a testing apparatus (Microtensile Tester, Bisco, IL, USA) and µTBS values were measured. Data were analyzed using the Kruskal-Wallis test and Mann-Whitney U test. Failure modes were analyzed under a stereomicroscope. Prolonged application time significantly affected the µTBS (p<0.005). A significant increase of µTBS on active application was observed for CUQ and GPB. The TUB with an active application had a significantly lower µTBS value compared with the other adhesives. Prolonged application time caused significant improvement of bond strength in all adhesives. The active application is effective at increasing the dentin bond strength except for TUB.


Resumen Este estudio evaluó los efectos de los modos alternativos de aplicación de adhesivos de autograbado en la resistencia de la unión microtensil entre resina y dentina (µTBS) de tres adhesivos universales de concepto "no espera" disponibles en el mercado. En este estudio se utilizaron terceros molares humanos impactados que fueron extraídos. Las superficies planas se prepararon en la dentina coronal media y se prepararon con un papel SiC de 600 granos. Los tres adhesivos universales que se utilizaron son los siguientes: Clearfil Universal Quick Bond (CUQ, Kuraray Noritake, Japón), G-Premio Bond (GPB, GC Corp, Japón), y un adhesivo universal autopolimerizable "Tokuyama Universal Bond" (TUB; Tokuyama Dental, Japón). Se utilizaron los tres procedimientos de aplicación siguientes para las superficies dentinarias: se aplicaron los adhesivos y se sometieron inmediatamente a un secado al aire; se aplicaron los adhesivos y se esperó 10 segundos; o se frotaron los adhesivos durante 10 segundos. Luego se aplicó resina compuesta a la superficie dentinaria y se fotopolimerizó. Después de su almacenamiento en agua destilada a 37°C durante 24 h, todos los dientes unidos se cortaron en secciones de 1mm² utilizando una sierra de diamante de baja velocidad (Micracut 125 Low Speed Precision Cutter, Metkon, Bursa, Turquía) bajo agua corriente (n=15). Las secciones fueron sometidas a una fuerza de tracción a una velocidad de cruceta de 1mm/min en una máquina de prueba universal (Microtensile Tester, Bisco, IL, USA) y se midieron los valores de µTBS. Los datos fueron analizados utilizando la prueba de Kruskal-Wallis y la prueba U de Mann-Whitney. Los modos de falla fueron analizados bajo un estereomicroscopio. El prolongado tiempo de aplicación afectó significativamente a los µTBS (p<0,005). Se observó un aumento significativo de µTBS en la aplicación activa para el CUQ y el GPB. El TUB con una aplicación activa tuvo un valor de µTBS significativamente más bajo comparado con los otros adhesivos. El tiempo de aplicación prolongado causó una mejora significativa de la fuerza de adhesión en todos los adhesivos. La aplicación activa es efectiva para aumentar la fuerza de adhesión de la dentina, excepto para el TUB.


Asunto(s)
Cementos Dentales/análisis
2.
Biosci. j. (Online) ; 38: e38087, Jan.-Dec. 2022. ilus, tab
Artículo en Inglés | LILACS | ID: biblio-1397493

RESUMEN

Photosystem-inhibiting herbicides, such as diquat, act by inducing oxidative stress. However, oxidative damage impairs translocation, resulting in regrowth of the plants. The aim was to evaluate the effectiveness of diquat in controlling the growth of sourgrass exposed to different periods of darkness after application of the herbicide, as well as to evaluate the photosynthetic activity and the production of reactive oxygen species. Two experiments (field and greenhouse) were conducted by applying diquat (200 g a.i. ha-1) on sourgrass plants at the 3 to 4 tiller stage. The treated plants were subjected to different periods of darkness after diquat application (0, 1, 2, 3, 4, 5, and 6 h), in addition to the control treatment without any application. Growth inhibition and mass evaluations of the sourgrass plants were performed in both experiments, whereas photosynthetic activity and H2O2 accumulation in the leaves were evaluated in the greenhouse experiment. The results showed an increase in the sourgrass growth inhibition with an increase in the period of darkness after application. There was a need for a minimum of 6 h of darkness after diquat application to fully inhibit growth (100%) of the sourgrass, whereas plants that remained in the sun since application exhibited less than 50% inhibition. The increase in the period of darkness after diquat application resulted in a reduction in photosynthetic activity and, consequently, lower accumulation of H2O2. Thus, the maintenance of sourgrass in the dark for at least 6 h enables total control of the growth of the plants, preventing regrowth.


Asunto(s)
Estrés Oxidativo , Digitaria/crecimiento & desarrollo , Control de Malezas , Herbicidas
3.
Journal of Korean Academy of Pediatric Dentistry ; (4): 165-172, 2019.
Artículo en Coreano | WPRIM | ID: wpr-787368

RESUMEN

The purpose of this study was to evaluate the effect of application time and phosphoric acid etching of 8th generation adhesives containing functional monomer on adhesive performance in primary teeth.80 extracted non-carious human primary teeth were selected and divided into 8 groups based on 3 factors: (1) adhesive: G-Premio bond and Single bond universal; (2) application time: shortened time and manufacture's instruction; (3) acid etching mode: self-etching and total-etching. Shear bond strength was measured using a universal testing machine, and fractured surface were observed under scanning electron microscope. Microleakage was evaluated by dye penetration depth.G-Premio bond were not significant different in shear bond strength and microleakage depending on application time of adhesive and acid etching mode. In Single bond universal, shear bond strength of short application time was significantly lower than that of long adhesive application time (p = 0.014). Clinically applicable shear bond strength values (> 17 MPa) were identified in all groups.These results suggested that G-Premio bond be used clinically for a short application time without phosphoric acid etching.


Asunto(s)
Humanos , Adhesivos , Métodos , Diente Primario
4.
Chinese Journal of Biochemical Pharmaceutics ; (6): 129-130,132, 2017.
Artículo en Chino | WPRIM | ID: wpr-615798

RESUMEN

Objective To investigate the best application time and effect of the prevention and treatment of postpartum hemorrhage caused by uterine atony. Methods A total of 168 women with bleeding tendency were treated in our hospital from October 2014 to October 2016. They were randomly divided into three groups, 56 cases each. Among them, A group was used immediately after delivery, and group B was suffering from uterine atony, which was the use of hemabate, and C group did not use hemabate. The blood loss and the amount of postpartum hemorrhage in the three groups were compared and analyzed. Results Compared with group B and C, the amount of bleeding, the amount of bleeding in the 2 hours postpartum and the amount of 24 hours postpartum hemorrhage in group A were significantly lower than that in group(P<0.05). The 2 hours postpartum bleeding volume and 24 hours postpartum hemorrhage in group B were significantly lower than that in group C(P<0.05). The incidence of postpartum hemorrhage in group A was 3.57%, significantly lower than that in group B, group 14.28% and group C, 30.36%(P<0.05). The incidence of postpartum hemorrhage in group B was 14.28%, significantly lower than that in group C (30.36%) (P<0.05). Conclusion To prevent and treat uterine atony postpartum hemorrhage, it is effective to prevent and treat postpartum hemorrhage. And the best application for the immediate use of fetal labor, can further reduce the amount of postpartum hemorrhage, to ensure maternal safety.

5.
Restorative Dentistry & Endodontics ; : 202-208, 2015.
Artículo en Inglés | WPRIM | ID: wpr-20258

RESUMEN

OBJECTIVES: This study determined the effect of the air-stream application time and the bonding technique on the dentin bond strength of adhesives with different solvents. Furthermore, the content and volatilization rate of the solvents contained in the adhesives were also evaluated. MATERIALS AND METHODS: Three adhesive systems with different solvents (Stae, SDI, acetone; XP Bond, Dentsply De Trey, butanol; Ambar, FGM, ethanol) were evaluated. The concentrations and evaporation rates of each adhesive were measured using an analytical balance. After acid-etching and rinsing, medium occlusal dentin surfaces of human molars were kept moist (conventional) or were treated with 10% sodium hypochlorite for deproteinization. After applying adhesives over the dentin, slight air-stream was applied for 10, 30 or 60 sec. Composite cylinders were built up and submitted to shear testing. The data were submitted to ANOVA and Tukey's test (alpha = 0.05). RESULTS: Stae showed the highest solvent content and Ambar the lowest. Acetone presented the highest evaporation rate, followed by butanol. Shear bond strengths were significantly affected only by the factors of 'adhesive' and 'bonding technique' (p < 0.05), while the factor 'duration of air-stream' was not significant. Deproteinization of dentin increased the bond strength (p < 0.05). Stae showed the lowest bond strength values (p < 0.05), while no significant difference was observed between XP Bond and Ambar. CONCLUSIONS: Despite the differences in content and evaporation rate of the solvents, the duration of air-stream application did not affect the bond strength to dentin irrespective of the bonding technique.


Asunto(s)
Humanos , Acetona , Adhesivos , Recubrimiento Dental Adhesivo , Dentina , Recubrimientos Dentinarios , Diente Molar , Hipoclorito de Sodio , Solventes , Volatilización
6.
Restorative Dentistry & Endodontics ; : 9-15, 2012.
Artículo en Inglés | WPRIM | ID: wpr-182032

RESUMEN

OBJECTIVES: This study evaluated the effect of 2% chlorhexidine digluconate (CHX) with different application times on microtensile bonds strength (MTBS) to dentin in class I cavities and intended to search for ideal application time for a simplified bonding protocol. MATERIALS AND METHODS: Flat dentinal surfaces with class I cavities (4 mm x 4 mm x 2 mm) in 40 molar teeth were bonded with etch-and-rinse adhesive system, Adper Single Bond 2 (3M ESPE) after: (1) etching only as a control group; (2) etching + CHX 5 sec + rinsing; (3) etching + CHX 15 sec + rinsing; (4) etching + CHX 30 sec + rinsing; and (5) etching + CHX 60 sec + rinsing. Resin composite was built-up with Z-250 (3M ESPE) using a bulk method and polymerized for 40 sec. For each condition, half of the specimens were immediately submitted to MTBS test and the rest of them were assigned to thermocycling of 10,000 cycles between 5degrees C and 55degrees C before testing. The data were analyzed using two-way ANOVA, at a significance level of 95%. RESULTS: There was no significant difference in bond strength between CHX pre-treated group and control group at the immediate testing period. After thermocycling, all groups showed reduced bond strength irrespective of the CHX use. However, groups treated with CHX maintained significantly higher MTBS than control group (p < 0.05). In addition, CHX application time did not have any significant influence on the bond strength among groups treated with CHX. CONCLUSION: Application of 2% CHX for a short time period (5 sec) after etching with 37% phosphoric acid may be sufficient to preserve dentin bond strength.


Asunto(s)
Adhesivos , Clorhexidina , Cementos Dentales , Dentina , Diente Molar , Ácidos Fosfóricos , Polímeros , Diente
7.
Journal of Korean Academy of Conservative Dentistry ; : 224-234, 2008.
Artículo en Coreano | WPRIM | ID: wpr-77634

RESUMEN

The purpose of this study was to compare the normal and two times of application time of six self-etching primers applied to enamel using microshear bond strength (uSBS) test and the finding of scanning electronic microscope (SEM). Crown of sixty human molars were bisected mesiodistally and buccal and lingual enamel of crowns were partially exposed and polished with 600 grit SiC papers. They were divided into one of two equal groups subdivided into one of six equal groups (n = 10) by self-etching primer adhesives. After the same manufacture's adhesive resin and composites were bonded on the enamel surface of each group, the bonded specimens were subjected to uSBS testing and also observed under SEM. In conclusion, generally two times of primer application time increased the enamel uSBS, especially with the statistical increase of bond strength in adhesives involving high-pH primers.


Asunto(s)
Humanos , Adhesivos , Coronas , Esmalte Dental , Electrónica , Electrones , Diente Molar
8.
Journal of Korean Academy of Conservative Dentistry ; : 435-441, 2005.
Artículo en Coreano | WPRIM | ID: wpr-73408

RESUMEN

The purpose of this study was to evaluate the effect of increasing application time of single bottle adhesives (SBA) to microtensile bond strength (MTBS) of dried dentin. To expose the superficial dentin surfaces, human molars were sectioned perpendicular to the long axis of tooth. 32% phosphoric acid gels were applied for 15s and rinsed. The teeth were randomly assigned to 3 groups ; S group (Single Bond), O group (One-Step), P group (Prime & Bond NT). Each group was divided to 3 subgroups (W: dentin wipe with wet gauge and light cured immediately, D: dentin dried for 30s and light cured immediately, 30: dentin dried for 30s and light cured after applying SBA for 30s). Composite resin was built up on the dentin surface and sectioned to obtain 20 specimens with 1 mm2 cross sectional area and the MTBS was measured. For Single Bond, the mean MTBS of S-W and S-30 group were higher than that of S-D group statistically (P < 0.05). For One-Step, the mean MTBS of O-D group was statistically lower than that of O-W group (P < 0.05). For Prime & Bond NT, the mean MTBS of P-30 group was statistically lower than that of P-D group (P < 0.05).


Asunto(s)
Humanos , Adhesivos , Vértebra Cervical Axis , Dentina , Geles , Diente Molar , Diente
9.
Journal of Korean Academy of Conservative Dentistry ; : 430-438, 2004.
Artículo en Coreano | WPRIM | ID: wpr-114827

RESUMEN

This study evaluated the influence of application time of self-etching primers on microtensile bond strength (microTBS) to dentin using three self-etching primer adhesive systems. Dentin surfaces were exposed from forty-eight human molars. They were conditioned with three self-etching primers (Clearfil SE Bond [SE], Unifil Bond [UF], Tyrian SPE + One Step Plus [TY]) and different primining times (10s, 20s, 30s and 40s). Composite resins were bonded to dentin surfaces and specimens were made. microTBS was tested and statistically compared using by one-way ANOVA and Tukey's Test The results of this study presented that priming time for 10s in SE and UF groups and for 30s and 40s in TY group was highly decreased microTBS to dentin.


Asunto(s)
Humanos , Adhesivos , Resinas Compuestas , Dentina , Diente Molar
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA